Page 161
Utilities
Chapter
12 12–Utilities
Chapter Contents
File Transfer ..............................................................................................12-5 Counters ....................................................................................................12-6 Part Number ..............................................................................................12-8 Checksum .................................................................................................12-9 Read Rate ...............................................................................................12-10 Device Control .........................................................................................12-12 Code Type ...............................................................................................12-13 Master Label Database ...........................................................................12-13 Defaulting/Saving/Initializing ...................................................................12-13
Utility commands are generally commands that are performed during scanner operations to check read rates, determine read rates or perform miscellaneous operations on scanner hardware. Serial utility commands are not prefaced with a “K”. Nor do they require an initialization command (<A> and <Z>). They can be entered from within any terminal program or from within ESP-MP in the Terminal window or the window adjacent to the Utilities menu. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
MS-850 Raster Scanner User’s Manual
12-1
Page 162
Utilities by ESP Menu
12–Utilities
Click this button to bring up the Utilities menu
To change a setting, right-click the setting and use your curser to scroll through the options.
Note: Utility commands are not accessible by embedded menus.
12-2
MS-850 Raster Scanner User’s Manual
Page 163
Chapter 12 Utilities
Utilities by Serial Command Table 12-1 Summary of Utility Serial Commands Command Type
Counter Request and Clear
Read Rate
Device Control
Code Types Commands Trigger
Default/Reset/ Save
Name Noread Counter Noread Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Display all three Checksums of Flash memory Display Checksum for Boot Code Display Checksum for Application Code Display both Part Numbers Display Boot Code Part Number Display Application Code Part Number Enter Single Label Percent Rate Test Enter Single Label Decode Rate Test Enter Multilabel Percentage Rate Test Enter Multilabel Decode Rate Test PDF Information Exit Decode Rate and Percent Rate Test Enable Laser Scanning Disable Laser Scanning Motor On Motor Off Programmable Output 1 Programmable Output 2 Programmable Output 3 Autodiscriminate All Codes Enable Code 39 Only Enable Codabar Only Enable I 2/5 Only Serial Trigger Character Reset (does not save for power-on) Default Restore Saved Settings Reset/Save (for power-on) Save Factory Settings Save/Restore Factory Defaults
MS-850 Raster Scanner User’s Manual
12–Utilities
Part Number Checksum/
Command <N> <O> <T> <U> <V> <W> <X> <Y> <!> <!b> <!a> <#> <#b> <#a> <Cp> <C> <Cm> <Cs> <a1> <J> <H> <I> <KE> <KF> <L1> <L2> <L3> <P> <Q> <R> <S> <char> <A> <Ad> <An> <Z> <Zp> <Zd>
12-3
Page 164
<E> <F>
12–Utilities
Master Label
Status Commands
<G> <Mmaster label number,data> <M?> <Mmaster label number,>
<-> <?> <?1> <K?>
Enable Master Label * Disable Master Label*
Store next label scanned to database.a Enter data to database for specified label* Request master label information* Delete Master Label*
Input Status Scanner Status Extended Scanner Status Configuration Status a. If no number is included, the label will be saved to database number 1. *Can also be set in the configuration menu or with a serial configuration command. (See Chapter 7, “Matchcode.”)
12-4
MS-850 Raster Scanner User’s Manual
Page 165
Chapter 12 Utilities
File Transfer File transfer is used to download application code to the scanner. Application code versions are specific to your scanner. Consult with your sales representative before downloading application code. If needed, an application code will be sent to you in the form of a *.mot file. To download application code: 1. First make sure the host is connected to your scanner. 3. In the Utilities window, right-click on File Transfer and select Download/App Code. This will open a file dialog box. 4. Navigate to the appropriate file (a *.mot file) and open the file. As application code begins to download to the scanner, the scanner will go silent, the scanner’s RDY and GD/RD LEDs will flash intermittently, and a progress indicator at the bottom of the ESP window will let you know when the download is complete. Caution: Do not interrupt power or disconnect the host cable while download is in progress.
MS-850 Raster Scanner User’s Manual
12-5
12–Utilities
2. Apply power to the scanner.
Page 166
Counters
Counters
12–Utilities
Counter commands can be a numeric value from 00000 to 65,535. After reaching the maximum numeric limit of 65,535, an error message will be displayed and the counter will automatically roll-over and start counting again at 00000. To obtain the cumulative total of counts after the roll-over has occurred, add 65,536 per each roll-over (the scanner does not keep track of the number of roll-overs) to the current count. Note: All counter values will be lost if power is recycled to the scanner or the scanner receives a reset or save command.
By ESP You can access Counters from the Utilities menu. Right-click the appropriate counter option and select Request to display count or Clear to set counter to zero.
By Serial Command Noread Counter Sending <N> displays the total number of noreads that have occurred since the last reset.
Noread Counter Reset Sending <O> sets Noread Counter to 00000.
Trigger Counter Sending <T> displays the total number of triggers since the last reset.
Trigger Counter Reset Sending <U> sets the trigger counter to 00000.
Good Read/Match Counter (or Good Read Counter) Sending <V> displays the total number of good reads matching the master label or, if Master Label is not enabled, the number of good reads since the last reset. This counter is always enabled, but will only work as a match count when Master Label is enabled. If Master Label is not enabled, this counter records the number of good reads. This count can be requested at any time.
12-6
MS-850 Raster Scanner User’s Manual
Page 167
Chapter 12 Utilities Good Read/Match Counter Reset Sending <W> sets the Match Counter to 00000.
Mismatch Counter Sending <X> displays the number of decoded labels since the last reset that do not match the master label.
Mismatch Counter Reset Sending <Y> sets the Mismatch Counter to zero.
12–Utilities
MS-850 Raster Scanner User’s Manual
12-7
Page 168
Part Number
Part Number You can send a request to the scanner for part numbers, checksums, boot code application code.
12–Utilities
By ESP You can access Part Number from the Utilities menu. Right-click the appropriate option and select Request to see the associated part number or check sum number.
By Serial Command Upon sending <#> the scanner returns software part numbers for application code <#a/__________> and boot code <#b/_________>. Individual part numbers for Application Code and Boot Code are returned when their respective commands <#a> and <#b> are sent.
12-8
MS-850 Raster Scanner User’s Manual
Page 169
Chapter 12 Utilities
Checksum You can send a request to the scanner for part numbers, checksums, boot code application code.
By ESP
By Serial Command Upon sending <!> the scanner returns three 4-digit hex numbers that are displayed under Check Sum. Checksums verify a scanner’s flash memory. Individual checksums for Boot Code and Application Code are returned when their respective commands <!b> and <!a> are sent.
MS-850 Raster Scanner User’s Manual
12-9
12–Utilities
You can access Checksum from the Utilities menu. Right-click the appropriate option and select Request to see the associated part number or check sum number.
Page 170
Read Rate
Read Rate You can do a read rate test for decode rate or percent by ESP or serial command.
By ESP You can access Read Rate from the Utilities menu.
12–Utilities
To start or end a read rate test, right-click Read Rate and select Start or Stop. To change from percent read rate to decodes per second, right-click Read Rate and make the selection.
By Serial Command Enter Single Label Decodes/Second Test Sending <C> instructs the scanner to transmit the decodes per second and label data (if any). The decode rate can vary dramatically due to the angle and location of the label in relation to the scan line. This test is very useful in aligning and positioning the scanning device during installation.
Enter Single Label Percent Test Sending <Cp> instructs the scanner to transmit the percentage of decodes and any scanned label data.
Enter Multilabel Percent Test Sending <Cm> instructs the scanner to transmit the percentage of scans decoded and label data (if any) for multiple labels.
Enter Multilabel Decode Rate Test Sending <Cs> instructs the scanner to transmit the decode rate and label data (if any) for multiple labels.
12-10
MS-850 Raster Scanner User’s Manual