Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 16 of 23

MS-850 Raster Scanner User's Manual, pages 151 to 160

Pages 151 to 160 of 222

The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-850

Page 151

Chapter 11 Diagnostics

Diagnostics by Embedded Menu For information on accessing the embedded menus, see “Embedded Menus” on page A-18. From the Main menu, scroll down through the options and select the following screen:

11–Diagnostics

MS-850 Raster Scanner User’s Manual

11-3

Page 152

Warning Messages

Warning Messages Important Note: Warning Message Status must be enabled before any warnings in this menu can be displayed. Definition:

Usage: Serial Cmd:

Warning messages that relate to the environment and condition of the scanner can be defined and set to activate specific outputs. Note: When enabled, the error condition will override all other operational modes configured for the output. When enabled, laser current and NOVRAM warning messages will be transmitted to the host or any active port whenever the pre-defined conditions are met. These messages serve as a flag to service a scanner or as an early warning that potential problems could arise. They are particularly useful in factories that run 24/7 and can’t afford down time. <K ”warning message status,laser high status,laser low status, novram/reset warning status>

Warning Message Status Function:

Usage: Serial Cmd:

11–Diagnostics

Default: Options:

When enabled, warning messages will be transmitted to the host or any active port. Note: This option must be enabled before any other warning messages can be transmitted. Alerts the user to impending failures or conditions that may soon cause failures. <K”warning message status,laser high status,laser low status, novram/reset warning status> Disabled 0 = Disabled 1 = Enabled

11-4

MS-850 Raster Scanner User’s Manual

Page 153

Chapter 11 Diagnostics

Laser High Warning Transmits a message whenever the laser current exceeds a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected.

Laser High Status Definition: Usage: Serial Cmd: Default: Options:

Enables the Laser High message. Alerts the user to impending laser failure. (Contact Microscan Service.) <K”warning message status,laser high status,laser low status, novram/reset warning status> Enabled 0 = Disabled 1 = Enabled

Laser High Message Definition: Serial Cmd: Default: Options:

Defines the Laser High message. <K;laser high message> HI-LASER Any 1 to 10 character ASCII string except NUL, <, or >.

11–Diagnostics

MS-850 Raster Scanner User’s Manual

11-5

Page 154

Warning Messages

Laser Low Warning When enabled a message up to 10-characters is transmitted whenever the laser current falls below a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected.

Laser Low Status Definition: Usage: Serial Cmd: Default: Options:

Enables the Laser Low message. Alerts the user to impending laser failure. (Contact Microscan Service.) <K” warning message status,laser high status,laser low status, novram/reset warning status> Enabled 0 = Disabled 1 = Enabled

Laser Low Message Definition:

11–Diagnostics

Serial Cmd: Default: Options:

When enabled a message up to 10-characters is transmitted whenever the laser current falls below a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected. Defines the Laser Low message. <K:laser low message> LO-LASER Any 1 to 10 character ASCII string except NUL, <, or >.

11-6

MS-850 Raster Scanner User’s Manual

Page 155

Chapter 11 Diagnostics

High Temperature Threshold A message can be defined that will display when a user-set High Temperature Threshold has been reached. The message repeats once every 30 minutes until the condition is corrected. This value is a reference to the external ambient temperature in the environment around the scanner.

High Temperature Degrees Definition: Usage:

Serial Cmd: Default: Options:

A user can set a temperature value that when exceeded will cause a high temperature message to be displayed. If High Temperature Threshold is set to zero, then the warning message will be disabled Helps ensure that the scanner is being used within its temperature specification. Also, since hotter environments tend to shorten the life of electronics components, a user may want to set the temperature threshold closer to the nominal temperature of 25°. <K+degrees,message> 50° Celsius 0° to 50°, zero disables.

High Temperature Message Definition: Serial Cmd: Default: Options:

The user can enter a 10-character message that will be displayed whenever High Temperature Threshold is exceeded. <K+degrees,message> HI_TEMP Any 1 to 10 character ASCII string except NUL, <, or >.

11–Diagnostics

MS-850 Raster Scanner User’s Manual

11-7

Page 156

Low Temperature Threshold

Low Temperature Threshold A message can be defined that will display when a user-set Low Temperature Threshold has been reached. The message repeats once every 30 minutes until the condition is corrected. This value is a reference to the external ambient temperature in the environment around the scanner.

Low Temperature Degrees Definition:

Usage: Serial Cmd: Default: Options:

The user can set a low temperature value that whenever the ambient temperature falls below it causes a low temperature message to be displayed. If Low Temperature Threshold is set to zero, the warning message will be disabled. Helps ensure that the scanner is being used within its temperature specification. <K – degrees,message> 1° Celsius 0° to 50°, zero disables.

Low Temperature Message Definition:

11–Diagnostics

Serial Cmd: Default: Options:

The user can enter a 10-character message that will be displayed whenever the ambient temperature falls below the Low Temperature Threshold. <K– degrees,message> LO_TEMP Any 1 to 10 character ASCII string except NUL, <, or >.

11-8

MS-850 Raster Scanner User’s Manual

Page 157

Chapter 11 Diagnostics

Lifetime Hours A message can be defined that will be transmitted whenever the scanner’s elapsed time clock exceeds the set hours threshold. The message repeats one time every 30 minutes.

Hours Threshold Definition:

Usage: Serial Cmd: Default: Options:

A user can set a time in hours that will cause a message to be sent whenever the scanner’s run time exceeds this value. The elapsed time is the time the scanner is powered up. Useful for setting up a preventive maintenance program. <K$ hours10,message> 2500 (actually 25,000 hours) 0 to 65534

Note: Hours entered are 1/10 of the actual hours.

Message Definition: Serial Cmd: Default: Options:

A user can define message up to 10-characters that will be displayed whenever the hours threshold is reached or exceeded. <K$hours10,message> SERVICE Any 1 to 10 character ASCII string except NUL, <, or >.

11–Diagnostics

MS-850 Raster Scanner User’s Manual

11-9

Page 158

Present Ambient Temperature (deg. C)

Present Ambient Temperature (deg. C) (This command is READ ONLY.) Definition:

Usage: Serial Cmd:

Close estimation of external temperature. A thermal sensor on the main PCB measures the internal temperature of the scanner. From this a case-differential constant is subtracted to yield an estimated external temperature. Indicates temperature of the environment immediately outside of the scanner. Useful for setting Over Temperature Threshold and Under Temperature Threshold. Send: <K%?> Returns <K% degrees Celsius>.

11–Diagnostics

Note: When viewing the Present Operating Temperature, allow at least 20 minutes after startup for the scanner’s inside and outside temperatures to stabilize.

11-10

MS-850 Raster Scanner User’s Manual

Page 159

Chapter 11 Diagnostics

Counts (These commands are READ ONLY.)

Powerups Definition Usage: Serial Cmd: Read Only Ranges:

Returns the number of times the scanner has been re-powered or a watchdog reset occurs. Useful for detecting unwanted resets caused by power supply problems or ESD transients. Send <K_> Returns <K_ powerups,resets> 0 to 65,535 powerups, 0 to 65,535 resets.

Resets Definition Usage: Serial Cmd:

Resets include watchdog reset, <A>, <Z>, <Zd>, and hardware defaults. A watchdog reset is a reset that is forced whenever the software locks-up. Useful for detecting unwanted resets caused by power supply problems or ESD transients. Send <K_> Returns <K_ powerups,resets>

Read Only Ranges:

0 to 65,535 powerups, 0 to 65,535 resets.

11–Diagnostics

MS-850 Raster Scanner User’s Manual

11-11

Page 160

Time Since Last Reset

Time Since Last Reset (This command is READ ONLY.) Definition: Usage: Serial Cmd:

Records the number of hours and minutes of operation since the last system reset. Useful as a troubleshooting tool that can help pinpoint the cause of a reset. Send <K@?> Returns <K@ hours,minutes> 0 to 23 hours, 0 to 59 minutes.

11–Diagnostics

Read Only Ranges:

11-12

MS-850 Raster Scanner User’s Manual