For the Microscan MS-850

Page 131

Chapter 9 Outputs

Noread Message Definition: Usage:

When enabled, and if no bar code label has been decoded before timeout or the end of the read cycle, the noread message will be transmitted to the host. See also “No Bar Code Message” on page 9-7. Used in applications where the host needs serial verification that a label has not been read and especially useful in new print verification.

Noread Status Serial Cmd: Default: Options:

<Kkstatus,message> Enabled 0 = Disabled 1 = Enabled

Noread Message Definition:

9–Outputs

Serial Cmd: Default: Options:

Any combination of ASCII characters can be defined as the noread message. <Kkstatus,message> NOREAD 0 to 7 ASCII characters.

Note: Noread Message will only be transmitted if Bar Code Output is set to Match, Mismatch or Good Read. Noread Message can be set to any ASCII characters except NULL <> and , (comma).

MS-850 Raster Scanner User’s Manual

9-5

Page 132

Bad Bar Code Message

Bad Bar Code Message Definition:

Usage:

When enabled, a message is sent to the host when a label is detected but not decoded. See “Transition Counter Threshold” on page 6-8. The Bad Bar Code output is tied to the transition counter. If during a read cycle no symbol is decoded and the required setting for the Transition Sample Threshold is met, a Bad Bar Code message will be sent to the host. See “Output Message Flow” on page 9-4. Useful in verifying the presence of a bar code label that has not been decoded.

Bad Bar Code Status Serial Cmd: Default: Options:

<K’status,message> Disabled 0 = Disabled 1 = Enabled

9–Outputs

Bad Bar Code Message Serial Cmd: Default: Options:

<K’status,message> BADCODE Up to seven ASCII characters (except NUL) The Bad Bar Code output is tied to the transition counter. If during a read cycle no symbol is decoded and the required setting for the Transition Sample Threshold is met, a Bad Bar Code message will be sent to the host.

9-6

MS-850 Raster Scanner User’s Manual

Page 133

Chapter 9 Outputs

No Bar Code Message Definition:

Usage:

When enabled, sends a message to the host whenever an object is detected but no bar code label is detected. See “Transition Counter Threshold” on page 6-8. The No Bar Code output is tied to the transition counter. If during a read cycle no symbol is decoded and the required setting for the Transition Sample Threshold is NOT met, a No Bar Code message will be sent to the host. See “Output Message Flow” on page 9-4. Useful in determining if an object has an attached bar code label.

No Bar Code Status Serial Cmd: Default: Options:

<KNstatus,message> Disabled 0 = Disabled 1 = Enabled

No Bar Code Message <KNstatus,message> NOLABLE Up to seven ASCII characters (except NUL)

MS-850 Raster Scanner User’s Manual

9–Outputs

Serial Cmd: Default: Options:

9-7

Page 134

Bar Code Output

Bar Code Output Note: Bar Code Output relates to data and should not to be confused with Outputs 1, 2, and 3 listed in the Outputs Parameters which describe output states and functions.

Bar Code Output Status Definition:

9–Outputs

Usage: Serial Cmd: Default: Options:

Defines the conditions under which decoded bar code labels are transmitted to the host. Useful when the host needs bar code data only under certain conditions. <Kloutput status,when to output> Good Read 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read

Note: Bar Code Output Status if set to Match or Mismatch will not take effect unless Matchcode Type is enabled and a master label is loaded into memory.

Disabled Definition: Usage:

When set to Disabled, the scanner will not transmit any data that is generated during a read cycle (bar codes, noreads, etc.). It is useful when an application only needs to use the discrete outputs and can allow the scanner to do the decision-making. When Disabled, the host does not need the bar code data and the communication lines are used only for setup and status checks.

Match Definition:

Usage:

9-8

When set to Match, the scanner transmits bar code data whenever a bar code matches a master label. However, if Matchcode Type is Disabled, it transmits on any good read. Note: A noread can still be transmitted if Enabled. Match is used in an application that requires specific bar code information and needs to sort, route or verify based on matching the specific bar code data.

MS-850 Raster Scanner User’s Manual

Page 135

Chapter 9 Outputs Mismatch Definition:

Usage:

With Mismatch enabled, the scanner transmits bar code data whenever the bar code data information does NOT match the master label. Note: A noread can still be transmitted if enabled. Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container.

Good Read Definition:

Usage:

With Good Read enabled, the scanner transmits bar code data on any good read regardless of Matchcode Type setting. Note: A noread can still be transmitted if enabled. Good Read is used when an application requires all bar code data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified.

When to Output Bar Code Data Serial Cmd: Default: Options:

This command allows the user to choose when bar code data can be sent to the host. <Kloutput status,when to output> As Soon As Possible 0 = As Soon As Possible 1 = End of Read Cycle

9–Outputs

Definition:

As Soon As Possible Definition:

Usage:

Enabling As Soon As Possible causes bar code data to be sent to the host immediately after a bar code has been successfully decoded. Note: More than one decode might in fact be required to qualify as a good decode, depending on how Decodes Before Output is set. As Soon As Possible is useful in applications in which bar code data needs to be moved quickly to the host, typically when the host is making decisions based on bar code data.

MS-850 Raster Scanner User’s Manual

9-9

Page 136

Bar Code Output End of Read Cycle Definition:

Enabling End of Read Cycle means that bar code data does not get sent to the host until the read cycle ends with a timeout or new trigger. End of read cycle

Start of read cycle Read cycle Duration Host activates trigger

This is when host expects output

Figure 9-2 Read Cycle End of Read Cycle is useful in timing-based systems in which the host is not ready to accept data at the time it is decoded.

9–Outputs

Usage:

9-10

MS-850 Raster Scanner User’s Manual

Page 137

Chapter 9 Outputs

Laser Control Laser On/Off Status Definition:

When enabled, the laser is ON only during the read cycle. When disabled, the laser operates continuously.

Click on this button to bring up the Outputs menu.

Usage: Serial Cmd: Default: Options:

Laser On/Off extends the life of the laser. It is useful where there are significant time gaps between symbols. It also provides visual confirmation of a read cycle duration and minimizes laser exposure to people. <KC laser on/off status> Disabled 0 = Disabled, 1 = Enabled

MS-850 Raster Scanner User’s Manual

9-11

9–Outputs

To change a setting, double-click on the setting and use your curser to scroll through the options.

Page 138

Serial Verification

Serial Verification Allows the user to verify configuration command status.

Serial Command Echo Status Definition: Function:

9–Outputs

Usage:

Serial Cmd: Default: Options:

When enabled, a configuration command received from the host is echoed back to the host with the resultant settings. If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change. This command is useful in removing any doubt about the scanner’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <Kd1, START> is entered, the scanner will echo back <Kd1, SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore it is rejected and the existing “SOM” message is echoed back and remains the preamble message. <KSserial command echo status,serial command beep status,control/hex output> Disabled 0 = Disabled 1 = Enabled

Serial Command Beep Status Definition: Function:

Usage: Serial Cmd: Default: Options:

9-12

Causes the scanner to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the scanner beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response. Used to audibly verify the acceptance and validity of a command. <KSserial command echo status,serial command beep status,control/hex output> Disabled 0 = Disabled 1 = Enabled

MS-850 Raster Scanner User’s Manual

Page 139

Chapter 9 Outputs

Control/Hex Output Definition:

Usage: Serial Cmd: Default: Options:

Determines the response to an Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as the two characters: ^M. When set to Hex, the output is the hex character. Useful for viewing settings with binary characters when using serial command on a terminal. <KSserial command echo status,serial command beep status,control/ hex output> Control 0 = Control 1 = Hex

9–Outputs

MS-850 Raster Scanner User’s Manual

9-13

Page 140

Beeper Status

Beeper Status Definition:

A beep is emitted either after each good read of a bar code label or after each noread. Note: Beeper will also sound if any of the following occur: • the scanner is defaulted • a send/save command from ESP or an Exit command from any embedded menu

Usage:

• a <Z>, <Zp>, <Zd>, or <KS,1> command is sent Can be used as an audible verification that either a good read or a noread has occurred.

Status

9–Outputs

Serial Cmd: Default: Options:

<Kustatus,volume> On Good 0 = Disabled 1 = On Good 2 = On Noread

Volume Serial Cmd: Default: Options:

9-14

<Kstatus,volume> Level 4 0 = Off 1 = Level 1 2 = Level 2 3 = Level 3 4 = Level 4 5 = Level 5

MS-850 Raster Scanner User’s Manual