Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 23

MS-820 Industrial Bar Code Scanner User's Manual: MS-820 Industrial Bar Code Scanner User's Manual, pages 21 to 30

Pages 21 to 30 of 222, from MS-820 Industrial Bar Code Scanner User's Manual

The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-820

Page 21

Chapter 1 Quick Start 1–Quick Start

Step 8, Compare Scanner Settings If you want to compare settings in the current scanner sideby-side with those in ESP without changing the ESP values: 1. Under the pull down Options menu check Show Comparison Column. 2. Right-click anywhere in the configuration window. 3. Select Retrieve as Comparison. After a short pause the scanner’s current settings will be displayed under the Comparison column. Compare those settings with the ESP values which are displayed under the ESP Values column. For example, if you change Background Color to Black, but haven’t yet saved this to the scanner, you will see the dissimilar program and scanner values highlighted in blue.

MS-820 Industrial Bar Code Scanner User’s Manual

1-9

Page 22

1–Quick Start

Step 9, Position Scanner and Symbol Set up a symbol at the scanning distance you will be using in your application.In positioning the scanner and symbols being scanned, consider the following: • Avoid bright light or IR light from other sources, including other scanners. • Pitch or skew label or scanner a minimum of ±15° to avoid specular reflection, the return of direct, non-diffused light. Note: For additional tips on positioning the scanner and bar code labels, see “Position Scanner and Bar Code” on page A-24.

30"

(76

2m

Note: The position of the scanners shown here is simply a suggested one for quick setup. There are variety of ways to mount the scanner. The important thing is to keep the test bar code label and scanner in the same relative position as shown here. If your manual is on a CD, look for a test label on the back of the CD cover.

m)

m) 40 8m mi (55 l la 22" ) be 20 mm l 3 mi 48 ( " l 15 lab 19 ) m mi m el 6 0 l lab (4 10 16" el mi ) l la mm be 305 ( l " 12 m) 4m (25 10" 7.5 mil

) mm mm) 7 mm) mm) 2 2 178 52 7" ( 6" (1 5" (1 4" (10

0"

Figure 1-3 Low Density Ranges

9" m) 9m (22 15 8" ) mi 10 mm l 3 mi 20 ( " l 5 ) 6.7 m ) 7.5 mm m 1 76 7 mi (1 3" ( l 5 mil 5" 2 . 3 ) 0" mm " ) 3 . 5 m ) (82 mm ) 40 m mm " (1 89 ( 2 0 5.5 1 4" (

Figure 1-4 High Density Ranges

Code 39 is the default code type enabled. If you are uncertain as to the symbology type, enable all codes, by clicking the Utilities menu and enabling Autodiscriminate under Code Types.

1-10

MS-820 Industrial Bar Code Scanner User’s Manual

Page 23

Chapter 1 Quick Start

1. Position a label in front of an operational scanner.1 20 mil Code 39 Test Symbol

You can also find test symbols on the back of the Microscan Marketing CD jacket. The 20 mil refers to the width of the narrowest bar (e.g., 7.5 mil = .0075" or .1905 mm).

2. Click the Utilities button. 3. Right-click Read Rate and select Start. 4. Observe rate in terminal window on the right of the Utilities screen. 5. Move your bar code label towards the scanner and away from the scanner until the decode rates drop off in each direction as shown in figure 1-1. This will give you a sense of the depth of field (inner and outer ranges) for your symbol’s density and range. 6. To end test, right-click Read Rate and select the Stop button.

u

De p th of f ield

Note: If the scanner is in the default Continuous Read mode, it will read and beep repeatedly as long as a readable label remains in the read range and the read cycle configuration has not changed.

Figure 1-5 Depth of Field

1. If using an I 2/5 label, verify that the number of characters in the label being scanned matches the code length enabled for the I 2/5 code type (default is 10 and 6). See “Interleaved 2 of 5” on page 5-14. MS-820 Industrial Bar Code Scanner User’s Manual

1-11

1–Quick Start

Step 10, Test Range for Bar Code Label

Page 24

1–Quick Start

Step 11, Make Changes to Configuration and Save To make changes to a configuration setting: 1. Double-click the setting (for example, End of Read Cycle).

2. Place your pointer in the selection box, scroll down to the setting of your choice and left-click on the setting. 3. Left-click again anywhere in the configuration window to complete the selection. 4. Right-click in the configuration window and select Save to Scanner to implement the command in the scanner. You have 3 choices: a. Send, No Save. This initializes all changes in active memory. These changes will be lost if power to the scanner is cycled. b. Send and Save. This will cause the scanner to beep, indicating that the change has been implemented and that all changes have been saved to the scanner’s NOVRAM for power-on, except factory settings.1 c. Advanced/Send and Save, Including Factory. Same as above, except that changes to factory settings will also be saved for power-on. Note: For Multidrop setup, see “Multidrop Communications” on page A-32.

1. Consult your model specific user’s manual for a list of factory settings.

1-12

MS-820 Industrial Bar Code Scanner User’s Manual

Page 25

Chapter

Communications

2 Host Port Parameters ..............................................................................2-4 Auxiliary Port............................................................................................2-5

This section tells how to setup communications parameters with the host and an auxiliary terminal. In addition, the options for auxiliary port connections are fully explored. With Microscan’s ESP-MP™ (Easy Setup Program) configuration changes can be made in the ESP-MP menus, then sent and saved to your scanner. The user can also send serial commands to the scanner via the ESP’s Terminal window. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

MS-820 Industrial Bar Code Scanner User’s Manual

2-1

2–Communications

Chapter Contents

Page 26

2–Communications

Communications by ESP

Click this button to bring up the Communications menu.

To change a setting, double-click the setting and use your curser to scroll through the options.

Communications by Serial Command Command Title Host Port Parameters Auxiliary Port Parameters Comm. Status Request

2-2 cmds Format Ka <Kabaud,parity,stop bits,data bits> <Kyaux port mode,baud,parity,stop bits,data Ky bits,daisy chain status,daisy chain ID> KT? <KT?>

MS-820 Industrial Bar Code Scanner User’s Manual

Page 27

Chapter 2 Communications

Communications by Embedded Menu In addition to ESP-MP, Microscan’s scanners have an embedded menu that can be accessed from the terminal window within ESP or a separate terminal program. See for instructions on using the embedded menus. For older, slower computers, the embedded menus might be a quicker method of communicating with your scanner. Send a <D> command from your terminal to bring up the main menu:

2–Communications

Press the return key (CR) to see the communications menu:

For information on accessing the embedded menus, see “Embedded Menus” on page 19.

MS-820 Industrial Bar Code Scanner User’s Manual

2-3

Page 28

Host Port Parameters

Host Port Parameters

2–Communications

Baud Rate, Host Port Definition:

The rate at which the scanner and host transfer data back and forth.

Usage:

Can be used to transfer data faster or to match host port settings.

Serial Cmd:

<Kabaud rate,parity,stop bits,data bits>

Default:

9600

Options:

0 = 600 1 = 1200 2 = 2400

3 = 4800 4 = 9600 5 = 19.2 K

6 = 38.4 K 7 = 57.6 K 8 = 300 K

Parity, Host Port Definition:

An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd.

Usage:

Only changed if necessary to match host setting.

Serial Cmd:

<Kabaud rate,parity,stop bits,data bits>

Default:

Even

Options:

0 = None

1 = Even

2 = Odd

Stop Bits, Host Port Definition:

One or two bits added to the end of each character to indicate the end of the character.

Usage:

Only changed if necessary to match host setting.

Serial Cmd:

<Kabaud rate,parity,stop bits,data bits>

Default:

One

Options:

0 = One

1 = Two

Data Bits, Host Port Definition:

One or two bits added to the end of each character to indicate the end of the character.

Usage:

Only changed if necessary to match host setting.

Serial Cmd:

<Kabaud rate,parity,stop bits,data bits>

Default:

One

Options:

0 = One

2-4

1 = Two

MS-820 Industrial Bar Code Scanner User’s Manual

Page 29

Chapter 2 Communications

RS422 Status Enables RS422. When RS422 is enabled, RS232 is enabled.

Usage:

Only changed if necessary to match host setting.

Serial Cmd:

<Kb status>

Default:

Disabled

Options:

0 = Disabled

2–Communications

Definition:

1 = Enabled

MS-820 Industrial Bar Code Scanner User’s Manual

2-5

Page 30

Auxiliary Port

Auxiliary Port

2–Communications

As with the host port parameters, the auxiliary terminal’s settings (baud rate, parity, stop bits, and data bits) must be identical with those of the auxiliary device. Definition:

An auxiliary port connects the scanner to a remote display or to other scanners that can display or transfer data.

Usage:

These commands set the communication parameters with the auxiliary port which can be used to configure menus, send data to the host, display data transmissions originating from the host of the scanner, and relay data from other scanners set in tandem (daisy chained).

Serial Cmd:

<Kyaux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Auxiliary Port Modes Definition:

Determines the flow of data between the auxiliary port device(s), the scanner, and the host.

Serial Cmd:

<Kyaux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

Disabled

Options:

0 = Disabled 1 = Transparent 2 = Half duplex 3 = Full duplex 4 = Daisy chain

2-6

MS-820 Industrial Bar Code Scanner User’s Manual