The text of a manual · part 2 of 23
MS-820 Industrial Bar Code Scanner User's Manual: MS-820 Industrial Bar Code Scanner User's Manual, pages 11 to 20
Pages 11 to 20 of 222, from MS-820 Industrial Bar Code Scanner User's Manual
The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-820
Page 11
Safety Labels The following labels are located on the side and back of the MS-820 scanner: 11-000024-01 Safety Label
UL, cUL
11-000031-01 S/N Label
1 1 -0 0 0 0 2 4 -0 1
1201 SW 7th St. Renton, WA 98055 www.microscan.com
CAUTION-LASER LIGHT WHEN OPEN-DO NOT STARE INTO BEAM. PRODUCT CONFORMS TO USA DHHS 21 CFR SUBCHAPTER "J"
C AU TIO N LASER LIGHT DO NOT STARE INTO BEAM.
FIS NO.
LAS ER STRA HLUNG NICH T IN DE N STRAHL BLI CKEN LASE R KLAS SE 2 94nJ @ 38uS
J2
EN 60825-1: 1994 DIN VDE 0837 Teil 1: 1994-07 650 nm LASER DIODE 1.0 MILLIWATT MAX
CLASS II LASER PRODUCT
V O RS ICH T
LASERSTRAHLUNG, WENN ABDECKUNG GEÖFFNET. NICHT IN DEN STRAHL BLICKEN
AVOID EXPOSURE
LISTED UL 1950 4k68
GD/RD SERIAL NUMBER/MODEL NUMBER
CE
CDRH
RDY
PWR 11-000031-01
MADE IN USA
LASER LIGHT IS EMITTED FROM THIS APERTURE on Top
MANUFACTURED tüV on Back
FCC on Bottom
BSMI
MS-820 Industrial Bar Code Scanner User’s Manual xi
Page 12
Warning and Caution Summary This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help For connection to a UL listed direct plug-in power unit marked Class II and rated 10 to 28 VDC at 2.7 watts or greater. European models must use a similarly rated Class I or Class II power supply that is certified to comply with standard for safety EN 60950.
WARNING Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous laser light radiation exposure. WARNING There are no user serviceable parts in the scanner. Opening the scanner voids the Microscan Systems warranty and could expose the user to laser diode power of up to 7 mW. WARNING The laser beam can be harmful to eyesight. Avoid eye contact with the laser beam. Never point the beam at other people, or in a direction where people may be passing.
xii
MS-820 Industrial Bar Code Scanner User’s Manual
Page 13
Quick Start
1 Chapter Contents Step 1 Hardware Required ......................................................................1-2 Step 2 Connect the System .....................................................................1-3 Step 3 Install ESP-MP .............................................................................1-4 Step 4 Select Scanner Model ..................................................................1-5 Step 5 Select the Communications Ports ................................................1-6 Step 6 Connect with Auto Connect ..........................................................1-7 Step 7 Retrieve Settings ..........................................................................1-8 Step 8 Position Scanner and Bar Code Label .........................................1-9 Step 9 Test Range for Bar Code Label..................................................1-10 Step 10 Make Changes to Configuration and Save...............................1-11
This chapter is designed to get your scanner up and running quickly using Microscan’s ESP-MP™ so the user can get a sense of its capabilities and test bar code samples. Detailed setup information for installing the scanner into the actual application can be obtained in the subsequent chapters. In addition to ESP, you can send commands to your scanner by serial commands and through the scanner’s embedded menus.
MS-820 Industrial Bar Code Scanner User’s Manual
1-1
1–Quick Start
Chapter
Page 14
(Refer to figure 1-1.) To get started you will need: • An MS-820 scanner (1). • A host computer (2) with either a terminal communications program or Microscan’s ESP™ which runs under Windows™ operating system, Windows-95 or higher, including Windows NT™. • A null modem configuration cable (3) (Use cable P/N 61-300026-01 if your computer uses a 25-pin serial port connector.)1 • A scanner to IB-131 interface cable (4), P/N 61-000011-01. • An IB-131 interface module (5). • A power supply (6), P/N 97-100004-1005 (120V) or P/N 97-100004-06 (240V). Caution: If using your own power supply, be certain that it is wired correctly and supplies voltage within the +10 to 28 VDC limits. Incorrect wiring or voltage can cause software or equipment failures. Note: An optional object detector (7) is shown here (P/N 99-440001-10). 1
4
2
5 Scanner
3 Host
Network
1–Quick Start
Step 1, Hardware Required
Power
Trigger
7 6
Figure 1-1 Hardware Configuration 1. If using another host cable, make certain it does not have RTS/CTS connected to the host.
1-2
MS-820 Industrial Bar Code Scanner User’s Manual
Page 15
Chapter 1 Quick Start
1. Connect the scanner to the IB-131 interface box, using the supplied cable with kit P/N 98-000014-01. If making up your own cable, make certain that you connect transmit pins to receive pins. 2. Connect IB-131 Host to Computer.1 (Refer to table A-3 and table A-8 for pin connections) 3. Use the host connector on the side of the IB-131 (figure 1-2) to connect with your host computer.
1
25
Figure 1-2 Side View of IB-131 showing Host 25-pin Connection Note: When wiring the IB-131 host connector to a 25-pin host connector (typical desktop computer connection), cross pins 2 and 3. When wiring the IB-131 host connector to a 9-pin host connector (typical portable computer connection), do NOT cross pins 2 and 3. (See figure 1-2.) 4. Connect power supply as shown in Step 1, “Hardware Required.” 5. Power up the scanner.
1. If using your own null modem RS232 host cable, be certain that the host’s TxD connects to the scanner’s RxD and the scanner’s TxD connects to the host’s RxD. MS-820 Industrial Bar Code Scanner User’s Manual
1-3
1–Quick Start
Step 2, Connect the System
Page 16
1–Quick Start
Step 3, Install ESP-MP1 (ESP-MP is short for Easy Setup Program–Multi-Platform.) 1. Insert your Microscan CD into your computer’s CD drive. 2. Launch Setup.exe under ESP_Software\Multi_Platform and follow the prompts.2 If downloading from the web: a. Go to http://www.microscan.com/esp b. Enter your user name and password. c. Select ESP-MP and download to your computer hard drive. d. Extract ESP-MP WinZip files to a directory of your choice. 3. Note where your ESP.exe file is stored on your hard drive. At the end of the install process, you should see the following icon on your desktop:
4. Click the ESP-MP icon to start the program.
1. You can also access the scanner through its embedded menus. See Appendix G, “Embedded Menus.” 2. Contact your sales representative
1-4
MS-820 Industrial Bar Code Scanner User’s Manual
Page 17
Chapter 1 Quick Start 1–Quick Start
Step 4, Select Scanner Model When you start the program, the following dialog box will appear:
Note: If you need to select another model later, you can find it under Model Select in the menu bar. 1. In the model dialog box, select your model. 2. Select the default name, MS-820-1 or type in a new name of your choice. 3. Click Yes when the following dialog on the right appears.
MS-820 Industrial Bar Code Scanner User’s Manual
1-5
Page 18
1–Quick Start
Step 5, Select the Communications Ports 1. Select your communications port under COM Port.
COM1 is typically used for laptops. COM1 and COM2 are typically for desktop computers. 2. Click the Start button.
1-6
MS-820 Industrial Bar Code Scanner User’s Manual
Page 19
Chapter 1 Quick Start
After clicking the Start button in the Connecting to... dialog, allow time for the auto connect routine to test all of the combinations. You will see a blue progress bar fill across the Connecting to... dialog. When connected, the CONNECTED message will appear in a green box in the status bar on the bottom right of the dialog.
Tip: If you do not see either the CONNECTED or DISCONNECTED message at the bottom of your dialog, try expanding the ESP window horizontally. Tip: If connection fails, enable a different Com port and try again.
MS-820 Industrial Bar Code Scanner User’s Manual
1-7
1–Quick Start
Step 6, Connect with Auto Connect
Page 20
1–Quick Start
Step 7, Retrieve Scanner Settings Unless you have unchecked the default Upload After Autoconnect under Options, the communications values of the scanner will be loaded automatically and displayed under Scanner Values. If Upload After Autoconnect is not checked, the scanner values will not be loaded and ESP communications values will remain displayed under the heading, ESP Values. Tip: Before doing Retrieve Scanner Settings, you may want to preserve your current ESP settings to your computer as an ESP file by selecting Save or Save As in the File menu. At any time you can retrieve ALL scanner values by: 1. Right-clicking anywhere in the configuration window, and 2. Selecting Retrieve Scanner Settings. You can also retrieve settings by clicking on the Send/ Receive button.
This is useful if you want to: • Copy (upload) the scanner’s settings and save them as a computer file for later retrieval. • Ensure that whenever you save ESP settings to the scanner you are not saving any unwanted changes that you or someone else had made previously in ESP. By first doing Retrieve Scanner Settings, you eliminate that possibility.
1-8
MS-820 Industrial Bar Code Scanner User’s Manual