Page 101

Chapter 6 Scanner Setup

(factory setting) Definition:

This field displays the current factory-set zero focus position.

Usage:

This field is READ ONLY, and is set by a qualified technician during factory setup.

Serial Cmd:

<KPdensity>

Default:

The default depends on the type of scanner.

Options:

0 = Low/Medium Density

1 = High Density

MS-820 Industrial Bar Code Scanner User’s Manual

6-5

6–Scanner Setup

Scanner Type

Page 102

6–Scanner Setup

Scan Speed

Scan Speed (factory setting) Definition:

Allows the user to set the number of scans per second by controlling the spinning mirror motor speed.

Usage:

Typically, to ensure a minimum number of scans, faster scan speeds are used for fast moving labels and/or longer labels with larger bar widths. See “Formulas for Number of Decodes” on page A-27. Note: Scan beams will be moving faster across labels further out in the scan range since the moving beam is being projected from a spinning mirror.

Serial Cmd:

<KEscan speed>

Default:

80 (x 10 scans per second)

Options:

35 to 110 (x 10 scans per second)

6-6

MS-820 Industrial Bar Code Scanner User’s Manual

Page 103

Chapter 6 Scanner Setup

(factory setting) Definition:

Sets a voltage amplitude value for the analog circuitry.

Usage:

Can be useful for fine-tuning gain or when portions of analog signals spike as in the case of specular reflection or extraneous noise. Caution: Changes to Gain are typically done by qualified technicians i.

Serial Cmd:

<KD gain,AGC sampling,AGC min,AGC max>

Default:

Default is 45 (nominal). Gain is optimized at the factory before shipment; the default value may not be 45.

Options:

10 to 255

MS-820 Industrial Bar Code Scanner User’s Manual

6-7

6–Scanner Setup

Gain Adjustment

Page 104

6–Scanner Setup

AGC Sampling

AGC Sampling Definition:

AGC is the acronym for Automatic Gain Control. AGC increases the depth of field by attempting to maintain signal strength at a constant level regardless of the range of the bar code label. AGC Sampling allows you to specify how automatic gain control sampling will be done.

Serial Cmd:

<KD gain,AGC sampling,AGC min,AGC max>

Default:

Continuous

Options:

0 = Disabled

1 = Leading Edge

2 = Continuous

Disabled Definition:

When AGC Sampling is set to Disabled, gain levels can only be manually controlled by the Gain command.

Usage:

Disabled is not recommended, but can be useful in certain applications in which labels do not require a large depth of field.

Leading Edge Definition:

Finds the leading edge of a symbol by looking for a 40 µs quiet zone followed by the number of transitions, stores the highest value of the samples, and adjusts the AGC accordingly at the end of the scan.

Usage:

Leading Edge is rarely used, but in some cases can improve scan rates when labels are skewed and the leading edge of a label is difficult to locate.

Continuous Definition:

Samples AGC throughout the scan at the rate averages the sample values, and adjusts the AGC value at the end of the scan.

Usage:

Continuous is the default and the preferred mode for sampling analog signal amplitude.

6-8

MS-820 Industrial Bar Code Scanner User’s Manual

Page 105

Chapter 6 Scanner Setup

(Read Only) Definition:

Limits the hardware gain available to the software for the usable range.

Serial Cmd:

<KD gain,AGC sampling,AGC min,AGC max>

AGC Maximum (Read Only) Definition:

Limits the hardware gain available to the software for the usable range.

Serial Cmd:

<KD gain,AGC sampling,AGC min,AGC max>

MS-820 Industrial Bar Code Scanner User’s Manual

6-9

6–Scanner Setup

AGC Minimum

Page 106

6–Scanner Setup

Transition Counter

Transition Counter Used for both AGC and label detection routines (see Chapter 8, “Outputs”). Definition:

During the read cycle, the scanner counts the number of bar and space transitions defined in the Transition Counter. If the count matches or exceeds the threshold, the scanner will perform AGC routines. The results of this test are also made known in output messages.See “Bar Code Output,” on page 8-8 and “Bar Code Output,” on page 8-8.

Transition Counter Status Serial Cmd:

<KH transition counter status,transition counter threshold>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Transition Counter Threshold Definition:

Determines the number of bar/space transitions that must be read before a label is considered present and AGC can be resolved.

Usage:

Can be useful in certain application where extraneous objects in the field of view might require a higher threshold.

Serial Cmd:

<KH transition counter status,transition counter threshold>

Default:

14

Options:

1 to 255

6-10

MS-820 Industrial Bar Code Scanner User’s Manual

Page 107

Chapter

Matchcode

7 7–Matchcode

Chapter Contents Overview of Matchcode ...............................................................................7-4 Matchcode Type ..........................................................................................7-5 Master Label Database .............................................................................7-10 New Master Pin .........................................................................................7-15

This section explains the matchcode output functions and the master label database setup. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

MS-820 Industrial Bar Code Scanner User’s Manual

7-1

Page 108

Matchcode by ESP

7–Matchcode

Click this button to bring up the Matchcode menu. To change a setting, double-click the setting and use your curser to scroll through the options.

Matchcode by Serial Command Command Title Master Label Database Size cmds KM

Matchcode Type

Kn

New Master Pin Store next label scanned to database.a Enter data to database Request Master Label information Delete Master Label

Kz G M M? M

Format <KMnumber of master labels> <Kntype,sequential matching,match start position,match length,wild card character, sequence on noread,sequence on mismatch> <Kzstatus> <G> <Mmaster label number,data> <M?> <Mmaster label number,> a. If no number is included, the label will be saved to database number 1.

7-2

MS-820 Industrial Bar Code Scanner User’s Manual

Page 109

Chapter 7 Matchcode

Matchcode by Embedded Menu For information on accessing the embedded menus, see “Embedded Menus” on page A-19. From the Main menu, scroll down through the options and select the following screen:

7–Matchcode

MS-820 Industrial Bar Code Scanner User’s Manual

7-3

Page 110

Overview of Matchcode

7–Matchcode

Overview of Matchcode Definition:

With Matchcode you can store master label data in the scanner’s memory, compare this data against the scanned bar codes, and define how label data and/or discrete signal output will be directed. A master label database can be setup for up to 10 master labels. See “Master Label Database” on page 7-10. Note: Matchcode will function with multiple labels (see “Multilabel” on page 4-14); however if Matchcode Type is set to Sequential or if Triggering Mode is set to Continuous Read 1 Output, Number of Labels will default back to 1 (if set to any number greater than 1).

Usage:

Matchcode is used in applications to sort, route, or verify data based on matching the specific bar code label in a variety of ways as defined in this section. For example, a manufacturer might sort a product based on dates that are embedded in the bar code.

Steps for entering and using master labels 1. Set Triggering Mode to External or Serial (“Trigger Mode” on page 4-4). 2. Chose the method of label comparison that fits your application (“Matchcode Type” on page 7-5). 3. Define the output you want to achieve with your matchcode setup: a. Barcode output (“Bar Code Output” on page 8-8). b. Discrete output (“Output 1” on page 9-4, “Output 2” on page 9-6, and “Output 3” on page 9-6). 3. Select the number of master labels you want to create (“Master Label Database Size” on page 7-10). 4. Decide which of 4 ways you want enter your master label(s): a. Use ESP to type in master label data directly (“Enter Master Label Data” on page 7-11). b. Send a serial command with label data in the form of <Mmaster label#,data>. c. Send a <G> (Scan Next Label as Master Label) command. d. Enable the New Master Pin command (“New Master Pin” on page 7-15) and activate a discrete input to store the in the next label scanned as master label. 5. Enter master label data using the method determined in step 4.

7-4

MS-820 Industrial Bar Code Scanner User’s Manual