Page 91
Chapter 5 Codes
Application Record Separator Status (UCC/EAN-128) Definition: Serial Cmd: Default: Options:
When enabled, a separator character is inserted between application records. <Kt,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enable
Note: Output Format must be set to Application Record before this parameter can take effect.
Application Record Separator Character (UCC/EAN-128) Definition: Serial Cmd: Default: Options:
Allows the user to define an ASCII character as an application record separator. <Kt,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> , (comma) User Defined ASCII character
Note: Output Format must be set to Application Record before this parameter can take effect.
Application Record Brackets (UCC/EAN-128) Definition: Serial Cmd: Default: Options:
When enabled, parentheses ( ) are added to enclose application identifiers. <Kt,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled
Note: Output Format must be set to Application Record before this parameter can take effect.
5–Codes
MS-820 Industrial Bar Code Scanner User’s Manual
5-23
Page 92
UCC/EAN-128
Application Record Padding (UCC/EAN-128) Definition:
Serial Cmd: Default: Options:
Padding is the insertion of zeros to make up the maximum length of a variable application record data field, except for the last field which does not require padding. When enabled, padding is included. When disabled, padding is omitted. Note: Padding is never added to fixed length fields or to the last data field of a label. Enabling or disabling Record Padding will have no effect on these. <Kt,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled
5–Codes
Note: Output Format must be set to Application Record before this parameter can take effect.
5-24
MS-820 Industrial Bar Code Scanner User’s Manual
Page 93
Chapter 5 Codes
Code 93 Definition:
Usage:
Code 93 is a variable length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces. Used occasionally in clinical industry.
Code 93 Status Serial Cmd: Default: Options:
<K!status,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled
Fixed Code Length Status (Code 93) Definition: Serial Cmd: Default: Options:
When enabled the scanner will check the label length against the code length field. If disabled any length would be considered a valid label. <K! status,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled
Fixed Code Length (Code 93) Definition: Usage: Serial Cmd: Default: Options:
Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any code not having the specified length. Fixed Code Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. <K! status,fixed code length status,fixed code length> 10 1 to 128
5–Codes
MS-820 Industrial Bar Code Scanner User’s Manual
5-25
Page 94
AIAG
AIAG Definition:
Usage:
5–Codes
ESP:
AIAG is not a bar code symbology, but rather a standard that enables a user to add information to symbols and to filter data according to userdefined identifiers (up to 12). AIAG is the Automotive Industry Action Group standard and is applicable to all symbologies. If when AIAG is enabled a decoded symbol has an AIAG ID, it will be counted. Otherwise, the symbol will be rejected. Originally created for identifying and sorting automotive parts and processes, AIAG is now used in a wide variety of industries for everything from quality control to data processing. From the Code Type menu, scroll to AIAG.
5-26
MS-820 Industrial Bar Code Scanner User’s Manual
Page 95
Chapter 5 Codes AIAG Status Serial Cmd: Default: Options:
<KZAIAG status, ID1, status1, ID2, status2, ID3, status3, ID4, status4, *ID5a,ID5b,ID5c, status5, ID6, status6, ID7, status7, ID8, status8, ID9, status9, ID9, status10, ID11, status11, ID12, status12> Disabled 0 = Disabled 1 = Enabled
AIAG Identifiers Definition:
AIAG has 12 Identifiers, each of which allows you to enter up to 4 ASCII characters with the exception of ID #5 which allows you enter 3 subidentifiers of 4 characters each.
Serial Cmd:
<KZAIAG status, ID1, status1, ID2, status2, ID3, status3, ID4, status4, *ID5a,ID5b,ID5c, status5, ID6, status6, ID7, status7, ID8, status8, ID9, status9, ID9, status10, ID11, status11, ID12, status12>
ESP:
Each Identifier can be individually changed. 1. Double-click on the individual identifier to bring up the screen shown on the right. 2. Select a character and click anywhere in the Code Type ESP window.
Default:
Status1 is Enabled by default. Status 2 through 12 are Disabled.
Options:
1 to 12 status settings; 1 to 12 user-defined identifiers.
Default identifiers for ID1 through ID12 are as follows: ID1
ID2
ID3
ID4
ID5a
ID5b
ID5c
ID6
ID7
ID8
ID9
ID10
ID11
ID12
N
P
Q
V
S
M
G
H
EZ
EB
ED
EC
EL
EX
The following rules apply: 1. Number of Labels <KZnumber> must be set to the number of AIAG symbols required per read cycle. (The number of AIAG IDs enabled has no effect.) 2. Any noread messages will be added to the end of the output with no ID prefix. For example, the following symbols - S123, N456, P678, and Q987 - are scanned in order but the third symbol P678 fails to be decoded. The noread output will appear at the end of the data array, as follows: S123,N456,Q987,NOREAD.
5–Codes
3. Symbol output is not sorted. 4. Allows any number of symbols with same ID if the data field is different.
MS-820 Industrial Bar Code Scanner User’s Manual
5-27
Page 96
Autodiscriminate
Autodiscriminate Although Autodiscriminate is not a configuration command, but it is included here as a convenient tool for enabling most code types. Definition: Usage:
ESP:
Serial Cmd: Default: Options:
Enables all available symbology types except PDF417, and UCC/EAN 128. The user may also individually disable/enable each symbology type. Commonly used for quick setup mode to detect bar code type. This is particularly useful for users who might be unfamiliar with their application’s symbology. Note: It does not alter individual fields such as Start/Stop, Fixed Length, etc. These need to be setup individually. In the Utilities menu, right-click on Autodiscriminate and select Enable. Note: There will be a few seconds delay while the scanner values are retrieved.
<P> Code 39 (only) <P> Enables all codes except noted above. <Q> Enable Code 36 only <R> Enable Codabar only
5–Codes
<S> Enable I 2/5 only Note: If using an I 2/5 label, verify that the number of characters in the label being scanned matches the code length enabled for the I 2/5 code type (default is 10 and 6).
5-28
MS-820 Industrial Bar Code Scanner User’s Manual
Page 97
Scanner Setup
6 Chapter Contents Scanner Type ..........................................................................................6-4 Scan Speed .............................................................................................6-5 Gain Adjustment ......................................................................................6-6 AGC Sampling .........................................................................................6-7 Transition Sample Counter ......................................................................6-9
This section includes AGC and factory settings such as Focus, Gain, Tracking, and Scan Speed. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
MS-820 Industrial Bar Code Scanner User’s Manual
6-1
6–Scanner Setup
Chapter
Page 98
6–Scanner Setup
Scanner Setup by ESP
Click on this button to bring up the Scanner Setup menu.
To change a setting, double-click on the setting and use your curser to scroll through the options.
6-2
MS-820 Industrial Bar Code Scanner User’s Manual
Page 99
Chapter 6 Scanner Setup 6–Scanner Setup
Scanner Setup by Serial Command Command Title comds
Scanner Type (factory) Scan Speed (factory) Gain Transition Counter Scanner Setup Status Request
KP KE KD KH
<KPdensity> <KEscan speed> <KD gain,AGC mode,AGC min,AGC max> <KH transition counter status,transition counter threshold>
Format
KU?
<KU?>
Note: To save Factory Settings changes to NOVRAM, send <Zp>, or if in ESP, select Save to Scanner/Advanced/Send and Save, Including Factory. (See “Save Active Settings including Factory for Power-on” on page -22.)
MS-820 Industrial Bar Code Scanner User’s Manual
6-3
Page 100
6–Scanner Setup
Scanner Setup by Embedded Menu For information on accessing the embedded menus, see “Embedded Menus” on page 19. From the Main menu, scroll down through the options and select the following screen:
6-4
MS-820 Industrial Bar Code Scanner User’s Manual