Page 19

Read Ranges Table 1-4 MS-520 Read Ranges and Scan Widths*

Maximum Scan Width

Narrow-Bar-Width

Read Range

.0047” (.119 mm)

1.75–3” (45–76 mm)

3” (76 mm)

.0075” (.191 mm)

1–4” (25–102 mm)

4” (102 mm)

.0075” (.191 mm)

2–5” (51–127 mm)

4.75” (121 mm)

.010” (.254 mm)

1.5–6” (38–152 mm)

6” (152 mm)

.015” (.381 mm)

1–7” (25–178 mm)

7.5” (191 mm)

.020” (.508 mm)

1–9” (25–229 mm)

9.25” (235 mm)

.030” (.762 mm)

4–10” (102–254 mm)

9.5” (241 mm)

.040” (1.02 mm)

4–10” (102–254 mm)

9.5” (241 mm)

.050” (1.27 mm)

5–10” (127–254 mm)

9.75” (248 mm)

Visible Laser UHD Range Standard Range

UHD Range Standard Range

.0047” (.119 mm)

1.75–3” (45–76 mm)

3” (76 mm)

.0075” (.191 mm)

1.25–3” (32–76 mm)

3.5” (89 mm)

.0075” (.191 mm)

2–4.5” (51–114 mm)

3.5” (89 mm)

.010” (.254 mm)

1.5–5” (38–127 mm)

4.75” (1.21 mm)

.015” (.381 mm)

1–6” (25–152 mm)

6” (152 mm)

.020” (.508 mm)

1–7” (25–178 mm)

7” (178 mm)

.030” (.762 mm)

4–9” (102–229 mm)

8.5” (216 mm)

.040” (1.02 mm)

4–9” (102–229 mm)

8.5” (216 mm)

.050” (1.27 mm)

5–9” (127–229 mm)

8.5” (216 mm)

* Performance may vary slightly for raster units.

To achieve optimum performance with your application, 1. Configure the decoder for read rate mode. 1 b. Temporarily position the scan head. c. Map out a label placement area by manually moving your label in and out and back and forth while observing read rates on the screen. Read rates will vary due to differences in label quality, positioning, etc.

1. See the decoder user’s manual for read rate test information. MS-520 Scan Head User’s Manual

2-7

2–Setup

Infrared Laser

Page 20

Chapter 2

Setup

Calculating the Number of Scans To ensure reliable scanning, it is recommended that a minimum of five scans be applied to each label.

2–Setup

The number of scans that a given label will receive can be calculated by formulas for both ladder and picket fence label orientations if the inputs listed below are known. • Scan Rate (SR) is the number of scans per second that a given scan head is capable of Label length emitting. • Scan Width (SW) is the width Label across the scan beam, at a height given distance from the scan head, in which a label can be Quiet zones read. • Label Speed (LS) is the disFigure 2-6 Label Dimensions tance per second that a label moves as it travels through the scan lines. • Label Length (LL) (for picket fence formula only) is the length of the longest printed label to be read plus the length of the quiet zones (figure 2-6). • Label Height (LH) (for ladder formula only) is a measurement of the height of individual bars (figure 2-6). .

Note: Label length and label height are always measured as shown in figure 2-6, regardless of label orientation.

2-8

MS-520 Scan Head User’s Manual

Page 21

Calculating the Number of Scans Use the formula 1 suitable for your application to predict the number of scans each label will receive.

Ladder Calculation

(

LH x SR LS

)

– 3 = number of complete scans

Example 1:

LH = 1 inch

2–Setup

LS = 10 inches per second SR = 330 scans per second

(

1 x 330 10

)

– 3 = 30 complete scans

Picket Fence Calculation

(

(SW – LL) x SR

LS Example 2:

)

– 3 = number of complete scans

LL = 1 inch (including quiet zones) SW = 2 inches LS = 10 inches per second SR = 330 scans per second

(

(2 – 1) x 330 10

)

– 3 = 30 complete scans

Note: If the number of complete scans calculates out to less than the minimum required for your application, assign the desired value to the number of complete scans and solve for any other parameter that can possibly be changed, such as label length, scan width, or label speed.

1. The -3 component (in both formulas) is added to allow for the first and last scans, and an AGC scan. MS-520 Scan Head User’s Manual

2-9

Page 22

Chapter 2

Setup

Comparing Label Orientation Calculations When evaluating ladder versus picket fence orientations (figure 2-7), label height, label length, and scan width are critical parameters. Note that in both previous examples, a 1 inch square label yields the same number of complete scans (30).

2–Setup

However, when label height or label length are changed, the resulting number of scans differs dramatically. For example, if both label height and label length are decreased to 0.5 inch for both examples (figure 2-7), the ladder orientation obtains 13 complete scans compared with 46 scans in the picket fence orientation. If label height and label length are both increased to 1.5 inches, the ladder rate goes up to 46 complete scans, compared to 13 complete scans in picket fence. Varying scan widths and label speeds will also alter the number of scans.

Direction of Label Travel

Ladder Orientation

Picket Fence Orientation

Figure 2-7 Label Orientations

2-10

MS-520 Scan Head User’s Manual

Page 23

Chapter

3

Installation

Chapter Contents

This chapter provides instructions for mounting the MS-520 scan head, interfacing with a decoder, and initial operation. Before permanently mounting the scan head, you should have read chapter 2, “Setup” and be confident that the scan head's mounting position and orientation will allow it to read the application's labels at the maximum read rate and with the desired number of scans.

MS-520 Scan Head User’s Manual

3-1

3–Installation

Mounting the Scan Head .......................................................... 3-2 Cabling ..................................................................................... 3-3 Operational Tips ....................................................................... 3-4

Page 24

Chapter 3

Installation

Mounting the Scan Head The MS-520 scan head can be mounted directly to a mounting surface of your choice, or indirectly, via a mounting plate and a universal stand. (See “Optional Equipment ” on page A-5.) To permanently mount the scan head: 1. Position the scan head in a dry place, devoid of sunlight, bright lights, or light from other sources. 2. Before mounting, ensure sufficient clearance at the rear of the scan head to allow for the 8-pin, RJ-45 connector and cable. 3. If not using the mounting plate, use the measurements provided in figure 1-1 to locate centers of mounting holes and drill four 5/32 inch (4 mm) holes. If using the mounting plate and a universal stand (see Appendix B, “Optional Equipment ”), use the four perimeter holes for mounting the plate and mount scan head directly to the four inner holes on the plate.

3–Installation

4. Secure scan head with four 6-32 screws . 2.25" (57.15 mm) 1.40" (35.56 mm)

.43" (10.92 mm) .32" (8.128 mm)

2.50" (63.5 mm)

1.50" (38.10 mm)

2.25" (57.15 mm)

6-32 threads (4 places)

Figure 3-1 MS-520 Bottom Mounting Holes (full size)

Caution: Do not allow the mounting screws to penetrate into the scan head case more than .175 inch (4.4 mm) or damage to the scan head may result.

3-2

MS-520 Scan Head User’s Manual

Page 25

Cabling

Cabling The standard cable supplied with a MS-520 scan head is 6 feet (1.83 cm) in length, wired with an 8-pin RJ-45 modular plug at each end.

1

1

8

8

Scan Head

+12 VDC in -12 VDC in Ground +5 VDC in Scan Sync out Scan Head Disable in Video (-) out Video (+) out

Bare wire Decoder

3–Installation

1 2 3 4 5 6 7 9

Figure 3-2 Scan Head/Decoder Interface Cable P/N: 61-130001-XX

Cables are also available in lengths from 1 to 15 feet, and are represented by a cable part number. For example, if 01 is substituted for XX in part number (PN) 61-130001-XX in figure 1-2, then the cable length would equal 1 foot (30.5 cm). To prevent voltage loss, cables between the decoder and scan head should not exceed 15 feet (5.9 m) unless wire sizes exceed the minimum 26 AWG, or power supply voltages at the scan head are verified to be within 8 percent.

MS-520 Scan Head User’s Manual

3-3

Page 26

Chapter 3

Installation

Operational Tips Do: • Check the label for readability in the visible (670 nm) or infrared (780 nm) range. If there is any question about the readability of the label, contact your Microscan representative. • Check inputs (label speed, length, height, etc.) to ensure the minimum number of scans per label required for your application. • As much as possible, avoid excessive tilt, pitch, and skew of the bar code label. • Test scan head readability with a label that is known to be good and log the results. • Clean the laser window on a regular basis with a clean, dry Q-tip or cotton cloth, without using excessive force.

3–Installation

Do Not: • Aim the scan head into sunlight, photo detectors, or other light-emitting sources. • Obstruct the laser window with mounting hardware or other objects. • Connect chassis of scan heads, decoders, and host to different ground potentials. • Operate the scan head in excessive temperature environments (see appendix A, “Scan Head Specifications”). • Connect or disconnect scan head/decoder interface cable while decoder power is ON.

3-4

MS-520 Scan Head User’s Manual

Page 27

Appendices

Contents Appendix A, Scan Head Specifications ............................................A-2 Appendix B, Optional Equipment .....................................................A-5 Appendix C, Glossary of Terms .......................................................A-7

Appendices

MS-520 Scan Head User’s Manual

A-1