The text of a manual · part 2 of 10
MS-5000 Multidrop Concentrator User's Manual, pages 11 to 20
Pages 11 to 20 of 94
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-5000
Page 11
Plan Scanning System
Bar-coded ite m flow
(m en u acc es s only )
Power supp ly
MS-5000 Multidro p Concentrator
Power supp ly
Object Detecto r
RS-232/422
Figure 1-1 shows a possible scanning system setup for the MS-4000.
HOST
MS-7000 Scanner
RS-485 J
Power supp ly
Obje ct Detecto r
M ultid rop T runk C a ble
MS-7000 Scanner
J
Power supp ly
Obje ct Detecto r
MS-7000 Scanne r
J
D rop C a ble
J = T-junction box
Figure 1-1 System Diagram; MS-7100 LAN
Option al Monitor Bar-coded item flow
-
(m e nu access o nly)
Power supp ly Object Detecto r
MS-5000 Multidrop Concentrator
Power supp ly
RS-485
AAd Dp P MS-610 Scanner Obje ct Dete ctor
RS-232/422
HO ST J
Power supply
AAd DP p
Figure 1-2 shows a possible scanning system setup for the MS-610. Note: The MS5000 concentrator uses an AC power pack to supply DC voltages.
M ultidrop Trunk C able J
MS-610 Scanner
Obje ct Dete ctor
Power supp ly p AAd DP
MS-610 Scanne r
J
D rop C ab le J = T-junction box
Ad p =
Adapter Junction Box
Figure 1-2 System Diagram; MS-610 LAN
MS-5000 Multidrop Concentrator User’s Manual
1-3
1–Setup and Inst.
Option al Monitor
Page 12
1–Setup and Inst.
Chapter 1
Setup and Installation Basic Rules for Multidrop Layout a. Overall length of main trunk cable (from concentrator to last physical device) in a multidrop network is 4000 feet. b. There can only be one continuous main trunk line. Drops to individual scanners are limited to 10 feet. See “Attach Cabling” on page 1-5 for more information on cabling. c. Modular RJ-11, 6-pin cable to first device (or junction) is crossed (see figure 1-3). d. All other modular RJ-11, 6-pin LAN cables to networked devices are pin-to-pin. e. Last device in network uses a 68 ohm terminal resistor (see Appendix E, “Terminal Resistor,” on page A-9). f. A new device can be added anywhere in system at anytime if new address is assigned.1 g. Addresses do not have to match the physical order in which scanners are connected.
Concentrator
Scanner or Decoder
Modular RJ-11 6-pin cable to 1st device is crossed
“Y” or “T” junction Scanner or Decoder
Subsequent modular RJ-11 6-pin cables are pin-to-pin
68¾ resistor in last junction or device between the receive lines of the last scanner
Scanner or Decoder
Figure 1-3 Multidrop Layout Diagram 1. The MS-5000 is “slow polling.” See “Polling Cycle Timing” on page 2-7.
1-4
MS-5000 Multidrop Concentrator User’s Manual
Page 13
Attach Cabling
The MS-5000 multidrop concentrator has the following four connectors on the rear panel (figure 1-4): • Power (5-pin DIN)
• LAN (modular 6-pin RJ-11)
• Host (25-pin D-subminiature)
• Monitor (9-pin D-subminiature) HOST
POWER
MONITOR
LAN
Figure 1-4 Rear Panel of MS-5000 Multidrop Concentrator
Table 1-1 Cable Distances Under ideal conditions, maximum cable lengths can meet the distances Maximum Cabling shown in table 1-1. However, since Distance cable lengths and sizes are dictated RS-232 Concentrator to Host 50’ (15.2 m) by local conditions such as wire size, RS-422 Concentrator to Host 4000’ (1219 m) shielding, grounding, extraneous signal noise, etc., maximum cable RS-485 Multidrop Trunk 4000’ (1219 m) distances will vary. RS-485 Multidrop Drop
10’ (3 m)
Note: Use shielding around all cables where extraneous noise could lead to errors in transmissions. See Appendix D, “Ground and Shield Considerations,” on page A-7.
MS-5000 Multidrop Concentrator User’s Manual
1-5
1–Setup and Inst.
2 Attach Cabling
Page 14
1–Setup and Inst.
Chapter 1
Setup and Installation
Power Connector The power connector uses a 5-pin DIN receptacle with the following pin assignments: If you are supplying the required DC voltages, a mating power connector (Switchcraft #05BL5M or Microscan 20-600099-01) is required. Table 1-2 Pin
Connection
1
DC Ground
2
Chassis Ground
3
+5 VDC .35A
4
-12 VDC .30A
5
+12 VDC .30A
3
1 5
2
4
Figure 1-5 Power Connector
Caution: Switching power supplies for Microscan equipment with a switching noise of 75 mV or greater with +5 VDC, or of 30 mV or greater with ±12 VDC is not recommended due to excessive ripple characteristics.Power Connector Pin Assignments.
1-6
MS-5000 Multidrop Concentrator User’s Manual
Page 15
Attach Cabling
Table 1-2 LAN Connector Pin Assignments
Pin
1
6
Signal
1
Ground
2
Receive Data (–)
3
Receive Data (+)
4
Transmit Data (–)
5
Transmit Data (+)
Figure 1-6 LAN Connector
The LAN 6-pin, RJ-11 modular connector is used for RS-485 multidrop communications. See pin assignments in table 1-2. Modular, 4-wire cables (preferably shielded) with 6-pin connectors are typical, but any round or flat data cable (minimum wire size: 24
AWG and minimum of four wires) can be used. An additional ground wire (figure 1-7) may be needed if the device chassis cannot be reliably earth-grounded. See Appendix D, “Ground and Shield Considerations,” on page A-7. See “Plan Scanning System” on page 1-2 for basic wiring patterns used in a multidrop system. Note: The last Microscan device in the multidrop network must be terminated correctly (see Appendix E, “Terminal Resistor,” on page A-9). In the first multidrop trunk cable 500 0 LA N (J7) 1st Ca ble 2nd and S ubse quent between the concentrator and Conn ector Conn ections Cable Connections the first logical device,1 transmit G nd 1 X and reception lines are crossed TXD TXD RXD- 2 (see figure 1-7). In subsequent TXD + TXD + RXD+ 3 trunk cable connections they are RXD4 RXDTXD NOT crossed but as shown in RXD+ RXD+ TXD + 5 figure 1-7. 6 An optional ground wire is shown in both cables. The shield shown in figure 1-7, if Figure 1-7 Multidrop LAN Wiring used, is connected to earth ground at the concentrator. (See also Appendix D, “Ground and Shield Considerations,” on page A-7.)
1. This applies to standard single concentrator networks and multiple concentrator networks. MS-5000 Multidrop Concentrator User’s Manual
1-7
1–Setup and Inst.
LAN Connector
Page 16
1–Setup and Inst.
Chapter 1
Setup and Installation
Host Connector The host connector allows the concentrator to be connected to a host or other communications device such as a PLC (programmable logic controller), a monitor, a PC, a relay, a diverter, an alarm, etc. via a 25-pin D-subminiature socket. The host is connected as a DTE (data terminal equipment) device with 25-pin D-subminiature connectors. Table 1-3 on page 1-9 shows pin assignments.
DB-25 DTE to DB-25 DTE Connection
Host
Decoder Transmit 2
2 Transmit
Receive 3
3 Receive
Signal Grnd 7
7 Signal Grnd
DB-25 DTE to DE-9 DCE Connection
Decoder
Host
Transmit 2
2 Transmit
Receive 3
3 Receive
Signal Grnd 7
5 Signal Grnd
Figure 1-8 DTE and DCE Host Connections
Pin 13
Pin 25
Pin 1
Pin 14
Figure 1-9 Host Connector (on concentrator
1-8
MS-5000 Multidrop Concentrator User’s Manual
Page 17
Attach Cabling Pin 1 2 3 4 5 6 7 8 9 10 11 12 13
Signal Chassis Ground Transmit Data Receive Data Request To Send Clear To Send Profile Card Signal Ground Profile Card +5 VDC Reserved Default Configuration Profile Card Receive Data B+
Pin 14 15 16 17 18 19 20 21 22 23 24 25
Signal Transmit Data A– Reserved Receive Data A– Reserved Reserved Transmit Data B+ Data Terminal Ready +12 VDC Profile Card Input Signal Ground –12 VDC +12 VDC Profile Card
Caution: Do not use a host cable with more wires connected than are required for the application. The host connector of the concentrator has many outputs that could cause damage or interfere with normal operation if connected and improperly used. Note: There must be ±12V present before the concentrator will transmit data to the host. However, the concentrator will receive commands without the presence of either voltage.
Monitor Connector The monitor connector links the concentrator to an auxiliary monitor via a 9-pin D-subminiature socket and cable. Table 1-4 shows auxiliary terminal pin assignments. Communication at this connector is RS-232 only. Table 1-4 Auxiliary Monitor Pin Assignments
Figure 1-10 Monitor Connector (on concentrator)
Pin
Signal
2 3 5
Receive Data (in) Transmit Data (out) Signal Ground
1. The default communications mode does not support pin 4 (RTS). If RTS is not required by the host, pin 4 should not be wired, as the results will be unpredictable. MS-5000 Multidrop Concentrator User’s Manual
1-9
1–Setup and Inst.
Table 1-3 Host Connector Pin Assignments1
Page 18
Chapter 1
Setup and Installation
1–Setup and Inst.
3 Configure Concentrator
Typical multidrop configuration is a two-step process: decoders, scanners, and other devices) are configured first, then the MS-5000 concentrator. The MS-5000 concentrator will communicate with lower level devices such as decoders, scanners, etc. only if those devices have been configured in Multidrop. Consult your scanner or decoder user's manual for its configuration instructions. In general, configuration settings between two devices will be made in the lower level device. For example, communications between a decoder and concentrator are made in the decoder, but communications between a concentrator and host are made in the concentrator. Communications, host protocol, and device status settings are stored in non-volatile memory and are configured from a host or auxiliary terminal either by menu selection (Chapter 3,), serial command (Chapter 4, “Serial Commands”), or profile card command (Chapter 5, “Profile Card Configuration”). Chapter 3, “Menu Configuration,” explains the configuration settings. To establish communication, the host’s or auxiliary terminal’s communication settings must match your concentrator’s settings (see Chapter , “Menu Configuration”). Also check that the code type enabled in the scanner or decoder matches the label in use. Communicating with an ASCII Terminal The MS-5000 concentrator communicates in full duplex, terminal mode with no handshake. It also recognizes carriage returns and line feeds. The host or ASCII terminal must match default settings of 9600 Baud Rate, Seven Data Bits, Even Parity, and One Stop Bit before any communication can occur. To use a PC or Macintosh computer as an ASCII terminal, a communications program (Procomm, Crosstalk, Kermit, etc.) set to the above defaults is required. See “Host Connector” on page 1-8 for connections and your computer manual for communication’s port pinouts.
1-10
MS-5000 Multidrop Concentrator User’s Manual
Page 19
Position Scanning Devices
Position the scanning devices and decoders (if used) relative to the labels you will be scanning in your application. Consult your scanning devices user’s manual for important setup procedures.
MS-5000 Multidrop Concentrator User’s Manual
1-11
1–Setup and Inst.
4 Position Scanning Devices
Page 20
Chapter 1
Setup and Installation
1–Setup and Inst.
5 Install Concentrator
Mount the concentrator temporarily using the four rubber pads, or permanently, as follows: a. Position the concentrator in a dry place. b. Before mounting, ensure that there is sufficient clearance at the rear of the concentrator for the connectors and cables. c. Use the measurements provided in figure 1-11 to locate centers of mounting holes and drill four 5/32 inch (4 mm) holes. d. Secure concentrator with four 6-32 screws. Caution: The mounting screws should not penetrate into the concentrator case more than 0.12 in. (3 mm) or damage to the unit could result. 0.5"(12.7)
5.6" (142.24) Front
1.85" (46.99)
6.2" (157.48)
2.5" (63.5)
6/32 threads (6.35m m ) 4 places
R e ar m easurem ents in inches (and m illim eters)
Figure 1-11 MS-5000 Bottom Mounting Diagram (not full size)
1-12
MS-5000 Multidrop Concentrator User’s Manual