For the Microscan MS-5000

Page 1 read from a scan by OCR; it may hold reading errors

MICROSCAN.

MS-5000 Multidrop Concentrator User's Manual

P/N 83-005000 REV G

Page 2

Copyright © 2000 by Microscan Systems, Inc., 1201 S.W. 7th Street, Renton, Washington, U.S.A. 98055 (425) 226-5700 FAX: (425) 226-8682 ISO 9001/Certification No. US96/0465 All rights reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Microscan manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Microscan. Throughout this manual, trademarked names might be used. Rather than put a trademark (™) symbol in every occurrence of a trademarked name, we state herein that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement.

Warranty Information Microscan Systems, Inc. warrants products manufactured by it to be free from defects in material or workmanship under normal use and service for a period of one year from date of shipment. This warranty is specifically limited to the replacement or repair of any such warrantable defects, without charge, when the complete product is returned to Microscan Systems, Inc., freight prepaid, at the address shown above. Contact the factory at the address above for a Return Material Authorization (RMA) number before returning the product. Microscan Systems, Inc. shall be the sole judge of the warrantability of alleged product defects. Products that are returned for warranty examination and that are found to be non-warrantable are chargeable and are returned freight collect. A copy of a purchase order with the amount of the charge must be received by Microscan, either by mail or by FAX, before any equipment is returned. Warrantable products are repaired or replaced at no charge and returned freight prepaid. THIS EXPRESS WARRANTY EXCLUDES ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PURPOSE. MICROSCAN SYSTEMS, INC., SHALL NOT BE LIABLE FOR WARRANTY IN ANY AMOUNT EXCEEDING THE PURCHASE PRICE OF THE GOODS. MICROSCAN SYSTEMS, INC., SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER IN CONTRACT, TORT, OR OTHERWISE. The buyer acknowledges that he/she is not relying on the seller's skill or judgment to select or furnish goods suitable for any particular purpose and that there are no warranties that extend beyond the description on the face hereof. This warranty extends only to the original purchaser, and shall not apply to any products or parts that have been subject to misuse, neglect, accident, or abnormal conditions or operations. Claims for damage in transit are directed to the freight carrier upon receipt.

Disclaimer The information and specifications described in this manual are subject to change without notice. For the latest version of this manual, see the Download page on our web site at www.microscan.com. For technical assistance, email helpdesk@microscan.com ii

MS-5000 Multidrop Concentrator User’s Manual

Page 3

Table of Contents List of Illustrations ................................................................................... v List of Tables...........................................................................................vi About the MS-5000 Concentrator ..........................................................vii About this Manual ..................................................................................vii Keystroke Entries...................................................................................vii Warning and Caution Summary............................................................ viii Approvals .............................................................................................. viii Safety Labels ........................................................................................ viii

Chapter 1

Setup and Installation

Step 1 - Plan Scanning System 1-2 Step 2 - Attach Cabling ....................................................................... 1-5 Step 3 - Configure Concentrator 1-10 Step 4 - Position Scanning Devices................................................... 1-11 Step 5 - Install Concentrator ............................................................. 1-12

Chapter 2

Multidrop Communications

Standard Single Concentrator Network ............................................... 2-2 Multidrop Addresses .................................................................... 2-2 Data to the Host ........................................................................... 2-2 Select Commands from the Host ................................................. 2-4 Polling Cycle Timing .................................................................... 2-7 Multiple Concentrator Network............................................................. 2-8 Multiple Poll Sequence ................................................................ 2-9 Multiple Select Sequence .......................................................... 2-10

Chapter 3

Menu Configuration

Using the Menu Configuration Program............................................... 3-2 Communications Menu ........................................................................ 3-5 Host Protocol Menu ............................................................................. 3-9 Polled Device Status Menu................................................................ 3-15 Time Keeping Menu........................................................................... 3-15 Exiting and Saving Menu Changes.................................................... 3-17

Chapter 4

Serial Commands

Summary of Serial Commands ............................................................ 4-2 Configuration Commands .................................................................... 4-3 Host Port .............................................................................................. 4-4 LAN Port .............................................................................................. 4-5 Auxiliary Port........................................................................................ 4-6 Host Protocol Commands .................................................................... 4-6 Time Keeping Commands ................................................................. 4-11 Operational Commands ..................................................................... 4-12 MS-5000 Multidrop Concentrator User’s Manual iii

Page 4

Chapter 5

Profile Card Configuration

Summary of Profile Card Modes .......................................................... 5-2 Operating Instructions .......................................................................... 5-3 Mode and Data Switch Settings ........................................................... 5-4 Binary Calculations............................................................................... 5-9

Appendices Appendix A, MS-5000 Specifications .............................................. A-2 Appendix B, Quick Reference Tables ............................................. A-3 Appendix C, Defaulting the MS-5000 .............................................. A-6 Appendix D, Ground and Shield Considerations ............................ A-7 Appendix E, Terminal Resistor ....................................................... A-9 Appendix F, Interface Standards ................................................... A-10 Appendix G, Glossary of Terms ..................................................... A-11

List of Illustrations Figure 1-1 System Diagram; MS-7100 LAN ..................................................... 1-3 Figure 1-2 System Diagram; MS-610 LAN ....................................................... 1-3 Figure 1-3 Multidrop Layout Diagram ............................................................... 1-4 Figure 1-4 Rear Panel of MS-5000 Multidrop Concentrator ............................. 1-5 Figure 1-5 Power Connector ............................................................................ 1-6 Figure 1-6 LAN Connector ................................................................................ 1-7 Figure 1-7 Multidrop LAN Wiring ....................................................................... 1-7 Figure 1-8 DTE and DCE Host Connections ................................................... 1-8 Figure 1-9 Host Connector (on concentrator .................................................... 1-8 Figure 1-10 Monitor Connector (on concentrator) ............................................. 1-9 Figure 1-11 MS-5000 Bottom Mounting Diagram (not full size) ...................... 1-12 Figure 1-12 MS-5000 (without housing) Mounting Diagram (not full size) ...... 1-13 Figure 2-1 Typical Multidrop Network ............................................................... 2-2 Figure 2-2 Polling Sequence ............................................................................ 2-3 Figure 2-3 Select Sequence ............................................................................. 2-4 Figure 2-4 Polling Cycle Durations for 25 Active Decoders ............................. 2-7 Figure 2-5 Multiple Concentrator Network ........................................................ 2-8 Figure 2-6 Concentrator to Decoder Polling Sequence .................................... 2-9 Figure 2-7 Concentrator to Concentrator Polling Sequence ............................. 2-9 Figure 2-8 Concentrator to Concentrator Select Sequence ............................ 2-10 Figure 2-9 Concentrator to Decoder Select Sequence ................................... 2-10 Figure 2-10 Concentrator to Lower Level Concentrator Select Sequence ..... 2-11 Figure 2-11 Special Multidrop Network ........................................................... 2-11 Figure 3-1 Main Menu ...................................................................................... 3-2 Figure 3-2 Communications Menu Structure .................................................... 3-5 iv

MS-5000 Multidrop Concentrator User’s Manual

Page 5

Figure 3-3 Host Protocol Menu Structure ......................................................... 3-9 Figure 3-4 Time Keeping Menu Structure ....................................................... 3-15 Figure 5-1 Profile Card Connection .................................................................. 5-3 Figure A-1 MS-5000 Dimensions ......................................................................A-2 Figure A-2 Profile Card Default Setting .............................................................A-6 Figure A-3 Host Connector Default Pins (on back of concentrator) ..................A-6 Figure A-4 Network Grounding Diagram ...........................................................A-8 Figure A-5 DIP Switch (in last MS-2000/MS-3000) ...........................................A-9

List of Tables Table 1-1 Cable Distances .............................................................................. 1-5 Table 1-2 Power Connector Pin Assignments ................................................. 1-6 Table 1-3 LAN Connector Pin Assignments .................................................... 1-7 Table 1-4 Host Connector Pin Assignments .................................................... 1-9 Table 1-5 Auxiliary Monitor Pin Assignments .................................................. 1-9 Table 1-6 Protocol Commands ...................................................................... 3-12 Table 4-1 Summary of Serial Configuration Commands ................................. 4-2 Table 4-2 Summary of MS-5000 Operational Commands .............................. 4-2 Table 4-3 Protocol Commands ........................................................................ 4-7 Table 5-1 Profile Card Mode Descriptions for the MS-5000 ............................ 5-2 Table 5-2 Calculating Binary Conversion ...................................................... 5-10 Table A-1 ASCII Table with Control Characters ..............................................A-3 Table A-2 Serial Configuration Commands for the MS-5000 ...........................A-4 Table A-3 Operational Commands for the MS-5000 ........................................A-4 Table A-4 Multidrop Address Characters .........................................................A-5

About the MS-5000 Concentrator The MS-5000 multidrop concentrator networks up to 50 devices (decoders, scanners, etc.) and sends the data (throughput speeds up to 38.4 K bits per second) to serial output to the host. The MS-5000 collects data from individual decoders, stores that data in battery-protected memory on a FIFO (“first in, first out”) basis, and sends it to the host upon request. The MS-5000 also enables the host to transmit commands to individual decoders and other devices in a multidrop-configured network.

MS-5000 Multidrop Concentrator User’s Manual v

Page 6

About this Manual This manual provides complete information on setting up, installing, and configuring the MS-5000 concentrator. Chapter 1 provides overall step-by-step instructions for setting up and installing the MS-5000 concentrator with specific “go to” references to other chapters and appendices. Chapter 2 describes various poll and select sequences with multidrop communications. Chapter 3 provides instructions for configuring the MS-5000 concentrator by menu. Chapter 4 provides instructions for configuring the MS-5000 concentrator by serial command. Chapter 5 provides instructions for configuring the MS-5000 concentrator by use of a Microscan profile card. For specifications, see appendix A. The appendices also include reference tables, as well as other useful information relating to bar coding and the MS-5000 concentrator.

Keystroke Entries Keystrokes to be entered from your terminal are highlighted in bold, as in <D>, including a < left angle bracket symbol and followed by a > right angle bracket symbol.

vi

MS-5000 Multidrop Concentrator User’s Manual

Page 7

Warning and Caution Summary Caution: There are no user serviceable parts in the MS-5000 concentrator. Opening the concentrator voids the Microscan Systems warranty. Caution: This equipment generates, uses, and can radiate radio frequency energy, and may cause interference to radio and TV communications. It has been tested and found to comply with the limits for Class A computing devices pursuant to Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area could cause interference, in which case the user, at his or her own expense, must take whatever measures may be required to correct the interference. For connection to a Listed direct plug-in power unit marked Class 2 and rated at 5 VDC @ 300 mA and ±12 VDC @ 40 mA.

Approvals CE Compliant

Safety Labels This certification label is located on the bottom of the MS-5000. 120 1 S .W . 7 th S t.

2

Ren ton, W A 980 55

THIS E Q UIP ME NT H A S B E E N TE S TE D W ITH C LA S S A C O MP UT ING D E V IC E S , A ND HA S B E E N FO UND TO C OM P LY W ITH P A RT 15 O F F CC RUL E S . S E E INS TR UC TION M A NU A L. OP E RA TIO N IN A RE S ID E NT IA L A RE A MA Y C A US E U NA C C E P TA B L E INTE RF E RE NC E TO RA D IO A ND TV RE C E P TION RE QUIRIN G THE OP E RA T OR TO TA K E W HA T E V E R S TE P S A RE NE C E S S A RY TO C OR RE C T THE INT E RF E RE N C E .

U.S . P A TE NT NO.: 4,855,581

R

P OW E R: +12V , - 12 V , + 5V ,

40m A 4 0mA 300m A

LIS T E D UL 19 50 4K 6 8

S E RIA L NU MB E R

11-10001 8-02

F IS N O.

M A D E I N U .S . A .

MA NUF A C TU RE D

CAUTION: The 6-32 mounting screws should not extend more than 0.12 in. (3 mm) into the mountingholes.

1 20 1 S .W . 7 th S t.

R e nto n, W A 9 80 5 5

T HIS E Q U IP M EN T H A S B E E N T ES T ED W IT H C L A S S A C O M PU T ING D E VIC E S, A N D HA S BE E N F O U ND T O C OM P LY W IT H P AR T 1 5 OF F C C R UL ES . S EE INS TR U C TION M A NU A L. OP E RA T IO N IN A R E S ID E NT IAL A RE A M AY C AU SE U N AC C E P TA BL E IN TE R F ER E N C E T O R AD IO AN D T V R EC E P TION R E QU IR IN G T H E OP E R AT OR T O T AK E WH AT E VE R S T EP S A R E N EC E S SA R Y TO C OR R EC T T HE INT E RF E R EN C E .

U .S. P AT E NT N O.: 4 ,8 55 ,5 81

2

P OW E R: + 12 V ,

4 0m A

- 12 V , + 5V ,

4 0 mA 3 00 m A

L I ST ED R

U L 1950 4K 68

S ER IA L NU M BE R

1 1-10 00 1 8-02

MS-5000 Multidrop Concentrator User’s Manual

F IS N O.

M AD E I N U .S . A.

M AN UF A C T U R ED vii

Page 8

viii

MS-5000 Multidrop Concentrator User’s Manual

Page 9

1

Setup and Installation Setup and Installation

Chapter Contents Step 1 - Plan Scanning System 1-2 Step 2 - Attach Cabling ....................................................................... 1-5 Step 3 - Configure Concentrator 1-10 Step 4 - Position Scanning Devices .................................................. 1-11 Step 5 - Install Concentrator ............................................................. 1-12

This chapter outlines the recommended steps for setting up your system and specific instructions for installing and attaching cabling to the MS-5000 multidrop concentrator. You need not follow the precise order of these steps if you are already familiar with Multidrop or have your system in place.

MS-5000 Multidrop Concentrator User’s Manual

1-1

1–Setup and Inst.

Chapter

Page 10

Chapter 1

Setup and Installation

1–Setup and Inst.

1 Plan Scanning System

Careful evaluation of the specific application - including the number, type, and location of scanners (or scan heads and decoders) and object detectors, as required - is a prerequisite to successful bar code scanning. Before installing the concentrator you should sketch out a diagram of your scanning system, showing equipment, connectors, and cable types and cable lengths. You should also evaluate the following: Scanning System. Examine each function of your operation and determine which transaction points need to be automated. Scanning Devices. The MS-5000 multidrop concentrator can be used with scanners or the combination of scan heads and decoders. (Call your Microscan representative for product specifications.) You may also incorporate bar code label printers, label applicators, diverters, alarms, and other devices into the system. Bar Code Symbology. Review your system when choosing a bar code symbol. Consider the information itself (numeric or alphanumeric), message length, how and where labels are applied, host software limitations, conveyor and scan speed, beam width, and scanning device range. Scanning Variables. See your scanning device user’s manual for information on ranges, label speed, etc. Environment. Check all product specifications (temperature, humidity, noise, ambient light, etc.) before installation to be sure your system environment is compatible.

1-2

MS-5000 Multidrop Concentrator User’s Manual