Page 64
Menu Configuration
To enable, press CR, SP, and CR. Press SP to advance to “Large Interchar Gap.”
Large Intercharacter Gap
Allows the scanner to read labels with gaps between bar code characters exceeding three times the narrow element width.
Large Intercharacter Gap is disabled by default. To enable, press CR, SP, and CR. Press SP to advance to Fixed Code Length.
Fixed Code Length
Used to increase data integrity by ensuring that only one label length will be accepted.
Fixed Code Length is disabled by default. To enable, press CR, SP, and CR. Press SP to advance to Code Length 1-31.
Code Length
Allows the user to specify the exact number of characters that the scanner will recognize. Any code not having the prescribed length will be ignored by the scanner. Available only when Fixed Code Length is enabled.
Code Length 1-31 is set to 10 by default. Code Length 1-31 is definable from 1 to 31 characters.
To change the default value, press CR, enter a number from 1 to 31, and press CR.
Press SP to cycle back to Code 39 status, or press M and SP to advance to Codabar.
Codabar
Codabar is disabled by default. Press CR to display the following on the command line:
CODE TYPES - - > CODABAR-> STATUS = DISABLED To enable, press CR, SP, and CR.
Series 4000 Raster Scanner User's Manual 3-31
Page 65
Chapter 3 Configuration
Press SP to advance. to Start & Stop Match.
Start & Stop Match
Requires the Codabar start and stop characters (a, b, c, or d) to match before a valid read can occur.
Start & Stop Match is enabled by default. To disable, press CR, SP, and CR. Press SP to advance to Start & Stop Output.
Start & Stop Output Allows the start and stop characters to be transmitted with bar code data. Start & Stop Output is enabled by default. To disable, press CR, SP, and CR. Press SP to advance to “Large interchar Gap.”
Large Intercharacter Gap
Allows the scanner to read labels with gaps between bar code characters exceeding three times the narrow element width.
Large Intercharacter Gap is disabled by default. To enable, press CR, SP, and CR. Press SP to advance to Fixed Code Length.
Fixed Code Length
Used to increase data integrity by ensuring that only label length will be accepted.
Fixed Code Length is disabled by default. To enable, press CR, SP, and CR. Press SP to advance to Code Length 1-31.
Code Length
Allows the user to specify the exact number of characters that the scanner will recognize. Any code not having the prescribed length will be ignored by the scanner. Available only when Fixed Code Length is enabled.
Code Length 1-31 is set to 10 by default.
3-32 Series 4000 Raster Scanner User's Manual
Page 66
Menu Configuration
Code Length 1-31 is definable from 1 to 31 characters.
To change the default value, press CR, enter a number from 1 to 31, and press CR.
Press SP to cycle back to Codabar status, or press M and SP to advance to | 2 of 5.
Interleaved 2 of 5
Because | 2 of 5 is a continuous code, it is prone to substitution errors. Hence, a code length must be defined and a bar code label containing an even number of digits must be used. It is also recommended that a Modulus 10 check digit be used to ensure the best possible data integrity.
| 2 of 5 is disabled by default. To enable, press CR, SP, and CR. Press SP to advance to Check Digit.
Check Digit | 2 of 5 uses a Modulus 10 check digit. Check Digit is disabled by default. To enable, press CR, SP, and CR. Press SP to advance to Check Digit Output.
Check Digit Output
When enabled, the check digit character is sent along with the label data. When disabled, label data will be sent without the check digit.
Check Digit Output is disabled by default. To enable, press CR, SP, and CR. Press SP to advance to Code Length # 1.
Code Length #1
With | 2 of 5, two code lengths can be defined. When using only one label length in an application, we recommend setting Code Length # 2 to 0 to ensure data integrity. If a check digit is used, it must be included in the code length count.
By default, Code Length # 1 is set to 10 characters. The user may specify a zero or any even code length from 2 to 30.
Series 4000 Raster Scanner User's Manual 3-33
Page 67
Chapter 3 Configuration
To change Code Length # 1, press CR, enter an even number from 2 to 30, and press CR.
(Entering an odd number will result in the next lower number being used.)
Press SP to advance to Code Length # 2.
Code Length #2 lf using a second label, the user has the option to again specify a zero or any even code length from 2 to 30. If a second label is not being used, set Code Length # 2 to 0 so that data integrity is ensured.
Code Length # 2 is set to 6 characters by default. To change the setting, press CR, enter the new number, and press CR.
(Entering an odd number will result in the next lower number being used.)
Press SP to cycle back to | 2 of 5 status, or press M and SP to advance to UPC.
UPC
UPC is the standard twelve digit retail code. When enabled, the scanner will read UPC version A and UPC version E only.
UPC is disabled by default. Press CR to display the following on the command line:
CODE TYPES -> UPC -> STATUS = DISABLED
To enable UPC, press CR, SP, and CR. Press SP to advance to EAN.
EAN
When enabled, the scanner will read UPC version A, UPC version E, EAN 13, and EAN 8.
When reading a UPC version A label with the EAN option enabled, a leading zero is appended to the label information and 13 digits are transmitted. If 13 digits are not desired when reading UPC version A labels, the EAN option must be disabled.
3-34 Series 4000 Raster Scanner User’s Manual
Page 68
Menu Configuration
EAN is disabled by default. | NOTE: UPC must also be enabled for EAN to take effect. |
To enable EAN, press CR, SP, and CR. Press SP to advance to Supplementals.
Supplementals
When enabled, the scanner can read supplemental bar code data that has been appended to the standard UPC or EAN codes.
Supplementals is disabled by default. The options are Disabled, Enabled, and Required.
When in Required mode, supplemental data must be found or a noread will result.
NOTE: Narrow Margins must be enabled if the gap size between the standard code and the supplemental code is between 5:1 and 10:1 (in relation to narrow-bar-width).
To change Supplementals press CR and use SP to scroll through the options. At the desired option press CR.
Press SP to advance to Separator.
Separator
When enabled, inserts a character between the standard UPC or EAN code and the supplemental code.
Separator is enabled by default. The default separator character is defined as a comma (,).
To retain the above default settings, press M and SP to advance to the Code 128 prompt.
To disable Separator, press CR, SP, and CR. Then press M and SP to advance to the Code 128 prompt.
To keep Separator enabled but change the separator character from a comma to a new value, press SP to advance to the following command line:
CODE TYPES-> UPC-> SEPARATOR = ,
Series 4000 Raster Scanner User’s Manual 3-35
Page 69
Chapter 3 Configuration
Press CR, enter the new Separator character, and press CR again. The new value ts displayed and will be transmitted as the Separator character between the decoded bar code data and the supplemental data.
Press SP to cycle back to the UPC status, or press M and SP to advance to Code 128.
Code 128
Code 128 is disabled by default. To enable, press CR, SP, and CR. Press SP to advance to Fixed Code Length.
Fixed Code Length
Used to increase data integrity by ensuring that only one label length will be accepted.
Fixed Code Length is disabled by default. To enable, press CR, SP, and CR. Press SP to advance to Code Length 1-31.
Code Length
Allows the user to specify the exact number of characters that the scanner will recognize. Any code not having the prescribed length will be ignored by the scanner. Available only when Fixed Code Length is enabled.
Code Length 1-31 is set to 10 by default. Code Length 1-31 is definable from 1 to 31 characters.
To change the default value, press CR, enter a number from 1 to 31, and press CR.
This is the last selection for Code 128. Press M to return to Code Types menu.
Press M again to return to the Main menu.
3-36 Series 4000 Raster Scanner User's Manual
~ 3
Page 70
Menu Configuration
User Outputs Menu
This menu allows the user to control the external (video or audio) outputs which identify scanning conditions. From the Main menu, press SP to advance to the User Outputs prompt. Press CR to see the following menu (figure 3-12):
(_ CURRENT SETTINGS FOR USER OUTPUTS >
BEEPER = ON GOOD
BEEPER VOLUME = LEVEL 4
FULL SCREENS = ENABLED . RELAY DRIVER = MISMATCH OR NOREAD NEW MASTER PIN = BISABLED
LASER ON/OFF = DISABLED
REVERSE VIDEO = DISABLED
GOOD/BAD POLARITY = POSITIVE
GOOD/BAB PULSE WIDTH = SO ms
COMMAND START CHARACTER = <
ESC = MAIN MENU OR EXIT N = NEXT ITEM M = PREVIOUS MENU SP = NEXT ITEM B = PREVIOUS ITEM CR = THIS ITEM
\ use OUTPUTS--> BEEPER = ON GOOD §j /
Figure 3-12 User Outputs Menu
Figure 3-13 displays the structure of this menu.
Series 4000 Raster Scanner User's Manual 3-37
Page 71
Chapter 3 Configuration
3-38
| NOTE Bold text represents User Outputs default settings. | I I T } Beeper Beeper Full Relay Driver New Master Pin Volume Screens On Good Level 4 ' Enabled - Mismatch or Disabled On Noread Level 5 Disabled Noread Enabled Disabled Level 4 Y Good Match Level 2 ; Level 3 r Mismatch, Noread | ] | T | Laser Reverse Good/Bad Good/Bad Command Start On/Off Video Polarity Pulse Width Character L Disabled L Disabled L Positive L 50 ms L < Enabled Enabled Negative User Definable User Definable
Figure 3-13 User Outputs Menu Structure
Beeper
A beep is emitted either after each good read of a bar code label, after each noread, or not at all, according to the setting.
On Good is enabled by default. The options are On Good, On Noread, or Disabled.
To change Beeper status, press CR. Press SP to scroll through the options, then CR at the desired option.
Press SP to advance to Beeper Volume.
NOTE: The beeper interrupts operations for approximately 100 ms. In high speed Multidrop operations it is advisable to disable the beeper for good reads since the time delay can cause labels to be missed.
Series 4000 Raster Scanner User’s Manual
Page 72
Menu Configuration
Beeper Volume
Level 4 is enabled by default. The options are Level 1 through Level 5.
To change Beeper Volume, at the volume prompt press CR and use SP to scroll through the levels. At the desired level, press CR.
The new volume level will be displayed in the command line and on the updated menu next to Beeper Volume.
Press SP to advance to Full Screens.
Full Screens
Allows the option of displaying either the full menu screen or just the command line.
Full Screens is enabled by default.
When Full Screens is disabled, the monitor will only display the command line.
To disable, press CR, SP, and CR. Press SP to advance to Relay Driver.
Relay Driver
Allows the user to determine the conditions under which a Relay Driver pulse of 5V is output.
Mismatch Or Noread is enabled by default.
The options are Mismatch Or Noread, Good Match, Mismatch, and Noread.
Relay Driver output pulse will work in all modes, but match and mismatch operations require that:
1. Match Code option be enabled, and
2. a master label be downloaded into memory.
A master label can be downloaded into memory with either a <G> or <)XXXX)> command, as shown in chapter 4, “Operational Commands.”
Series 4000 Raster Scanner User’s Manual 3-39
Page 73
Chapter 3 Configuration
Table 3-1, “Relay Driver Options/Outputs” shows the effects of each of the four Relay Driver options under various scanning conditions.
| NOTE: This table is only valid if Match Code is enabled. |
Table 3-1 Relay Driver Options/Outputs
Output Counter incremented o Option by one? “ rs 2 enabled ~|32]3 under Scanning Result 5 . a a ° -, a] Bl8igiS/Slols _ &(/oi%|]Silo SIS|/E;S|a/o] 8 2|S|5/8/2/8\8 * Matches the master label Viv Mismatch ¢ Does not match the master label | ¥ v Vv * Label not decoded ¥ viv V e Matches the master label viv Viv woot . ¢ Does not match the master label | ¥ ¥ e Label not decoded v Vv * Matches the master label viv Mismatch | Does not match the master label | ¥ ¥ viv * Label not decoded v v * Matches the master label! Viv Noread | Does not match the master label | ¥ ¥ * Label not decoded v viv ¥
A. Pin 2 of trigger connector. B. Pin 6 of host connector. C. Pin 8 of host conncecor.
3-40 . Series 4000 Raster Scanner User's Manual