Menu Configuration

Mismatch or Noread

A pulse is sent to pin 2 of the trigger connector (J2) when a label's data does not match that of the master label, or the label is not decoded before the end of the read cycle.

Good Match

A pulse is sent to pin 2 of the trigger connector when a label's data matches that of the master label.

Mismatch

A pulse is sent to pin 2 of the trigger connector when a label's data does not match that of the master label.

Noread

A pulse is sent to pin 2 of the trigger connector when no data is decoded before the end of the read cycle.

To change Relay Driver, press CR and use SP to scroll through the options. At the desired option, press CR.

Press SP to advance to New Master Pin.

New Master Pin

When enabled, allows the user to externally toggle pin 25 to momentarily bring it to ground (pin 7). This clears any existing master label information from memory and records the next good read as the new master label information.

New Master Pin is disabled by default. To enable, press CR, SP, and CR. Press SP to advance to Laser On/Off.

Laser On/Off

When enabled, the laser is ON only during the read cycle, provided the scanner is enabled for a Serial or External trigger (see “Triggering Mode” under “Operations Menu”).

NOTE: Laser On/Off should not be confused with the <H> and <I> operational commands (chapter 4).

Series 4000 Raster Scanner User’s Manual 3-41

Page 75 read from a scan by OCR; it may hold reading errors

Chapter 3 Configuration

When Laser On/Off is disabled, the laser will operate continuously. Laser On/Off is disabled by default. To enable, press CR, SP, and CR.

Press SP to advance to Reverse Video.

Reverse Video

When enabled, the scanner will read bar code labels with white bars. Reverse Video is disabled by default.

To enable, press CR, SP, and CR.

Press SP to advance to Good/Bad Polarity.

Good/Bad Polarity

Allows the user to choose between positive and negative output signals for pins 6 (good read) and 8 (noread) on the host connector and pin 2 on the trigger connector.

Positive is enabled by default.

To change to Negative, press CR, SP, and CR. Press SP to advance to Good/Bad Pulse Width.

Good/Bad Pulse Width

Allows the user to set the duration of the good read/no read output signals at host port pins 6 and 8 on the host connector and pin 2 on the trigger connector by entering any number from 0 to 255. (Divide the number entered on the command line by 100 to obtain the time in seconds.)

Good/Bad Pulse Width default setting is 50 ms (.05 seconds). (The displayed value is 5 on the command line.)

To change Good/Bad Pulse Width, press CR and enter the new value (0 to 255). This number is derived by multiplying the required number of seconds times 100.

Press CR to enable. Press SP to advance to Command Start Character.

3-42 Series 4000 Raster Scanner User’s Manual

Page 76 read from a scan by OCR; it may hold reading errors

Menu Configuration

Command Start Character

Allows the user to define a new ASCII start character in a serial command.

The default character for Command Start Character is <.

To change Command Start Character, press CR, enter any ASCII character, and press CR again.

Press M to return to the Main menu. Press SP to advance to Raster Setup Menu.

Series 4000 Raster Scanner User’s Manual 3-43

Page 77 read from a scan by OCR; it may hold reading errors

Chapter 3 Configuration

Raster Setup Menu

From the Main menu, scroll to Raster Setup and press CR. Figure 3-14 shows the menu for Raster Setup:

( - CURRENT SETTINGS FOR RASTER SETUP \

STATUS = ENABLED TOP OFFSET IN DEGREES = oO BOTTOM OFFSET IN DEGREES = 45 SWEEPS PER SECOND = 14

ESC = MAIN MENU OR EXIT N = NEXT ITEM M = PREVIOUS MENU SP = NEXT ITEM B = PREVIOUS ITEM CR = THIS ITEM

\ erSTER SETUP--> STATUS = ENABLED yy,

Figure 3-14 Raster Setup Menu

- Figure 3-15 shows the structure of this menu:

NOTE Bold text represents Raster Setup default settings. | I T i Status Top Offset Bottom Offset Sweeps Per in Degrees In Degrees Second Enabled 7 0 i 45 14 - Disabled User Definable User Definable User Definable

Figure 3-15 Raster Setup Menu Structure

3-44 Series 4000 Raster Scanner User’s Manual

Page 78 read from a scan by OCR; it may hold reading errors

Menu Configuration

Table 3-2 Raster Settings

Minimum |Maximum Raster Sweeps | Sweeps Top Offset Arc per per - 0° Second Second MS-4280 1° | 135 Raster 5 Scanner 5 1 78 10° 1 45 15° 1 35 20° 1 29 25° 1 23 30° 1 21 Bottom Offset 35° 1 19 = 45 40° 1 17 45° 1 14

Figure 3-16 Raster Sweep Arc

Raster Setup is configured with the defaults as shown in figure 3-14 and 3-15. Both top and bottom offsets as well as raster sweeps per second are adjustable by menu command.

For additional information on raster setup, see “Raster Height and Raster Arc” and “Calculating Number of Scans” in chapter 2.

Raster Setup is disabled by default. To enable, press CR, SP, and CR. Press SP to advance to Top Offset In Degrees.

Top Offset in Degrees

Top Offset is adjustable from 0 degrees to a maximum of 45 degrees in one-degree increments.

The default value for Top Offset in Degrees is 0 degrees.

To change Top Offset in Degrees, press CR, enter any number from 0 to 45, and press CR again.

Series 4000 Raster Scanner User's Manual 3-45

Page 79 read from a scan by OCR; it may hold reading errors

Chapter 3 Configuration

Press SP to advance to Bottom Offset In Degrees.

NOTE: Top Offset must always be less than the bottom offset or the resulting arc will be 0.

Bottom Offset in Degrees

Bottom Offset is adjustable from 0 degrees to a maximum of 45 degrees in one-degree increments.

The default value for Bottom Offset in Degrees is 45.

To change Bottom Offset in Degrees, press CR, enter any number from 0 to 45, and press CR again.

Press SP to advance to Sweeps Per Second.

Sweeps Per Second

Allows the user to control the raster motor speed.

A “sweep” is defined as a single pass, up or down, describing the raster image.

Table 3-2 shows minimum and maximum possible sweep speeds at selected raster arcs. The minimum possible speed at any arc is always one sweep per second. Maximum sweep speeds are the maximums to which the scanner defaults even if higher speeds are entered by the user.

To maximize the number of scans a label will receive, it is recommended that as few as possible sweeps per second be selected. However, to ensure that the minimum required scan lines cross the bar code label, it is essential that at least two full sweeps occur during the time it takes for the label to pass through the readable scan width area.

For example, if the label is readable in the read range for only 1/10th of a second, then the number of sweeps per second should be at least 20. If readable for only 1 second, then sweeps per second (SPS) should be at least 2. (To see a formula for calculating sweeps per second, see “Calculating Number of Scans” in chapter 2.)

The default value for Sweeps Per Second is 14.

To change Sweeps Per Second, press CR, enter any number from 0 to 135, and press CR again.

3-46 Series 4000 Raster Scanner User’s Manual

Page 80 read from a scan by OCR; it may hold reading errors

Menu Configuration

This concludes the items in the Menu Configuration program. Press M to return to the Main menu.

Saving Menu Changes Press ESC (Escape key) to see the following on the command line:

EXIT OR MAIN MENU [E, M}

Press M to return to the Main menu, or press E to exit the Menu Contfig-uration program. If E is pressed, the following question will appear:

Do you want to save changes for power up? [Y = yes N = no)

Press N to exit without saving changes to non-volatile RAM, or press Y to retain the current settings for power up. If Y is selected, a second beep will indicate the save has been carried out.

Series 4000 Raster Scanner User’s Manual 3-47

Page 81 read from a scan by OCR; it may hold reading errors

Chapter 3 Configuration

Serial Configuration

All of the configuration changes to the scanner that can be made in the menu can also be accomplished by command strings from the host.

Serial command strings (also called “K" commands) are entered from an ASCII terminal. As with menu configuration commands, serial configuration commands relate to the initial scanner setup.

For an alphabetical listing of serial configuration commands, see table 3- 5, “Summary of Serial Configuration “K” Commands,” at the end of this section. Trigger Filter Timing Value command, listed immediately prior to “Communications” in this section, is not an option in the menu configuration program.

Serial Command Format

The format for a serial configuration command is,

<KparameterdataA, dataB...etc.>

For example, the following command enables UPC: <Ks1>.

When using serial configuration commands, note the following conven-tions:

e “K" is the symbol used to represent a configuration change. e “Parameter” is a single alphabetical character.

e Parameters and data are “case sensitive;” that is, characters must be entered as upper or lower case, as specified.

e Data fields must be separated by commas but no spaces.

e If there is no change in a given field, then commas can be entered alone, or with the existing data (for example, <Ka,,,0> or <Ka4,1,0,0>).

e Ail fields before the one being modified must be included. For example, in Host Port, to change data bits to eight without changing any other field, enter either: <Ka,,,1> or <Ka4,1,0,1>. However, fields which come after the modified field can be left out. The effect is that all other settings remain as they were before the command was sent.

When commas are used alone without field data, the existing field remains unchanged. This is helpful when a command change has several data options in the format.

(See examples on following pages.)

3-48 Series 4000 Raster Scanner User's Manual

Page 82 read from a scan by OCR; it may hold reading errors

Serial Configuration

Implementing Serial Commands

To ensure that a serial command will take effect, one of the following serial operational commands must be added after the “K” command or, in the case of concatenated commands, after the last “K" command.

¢ <A> Reset, to initialize changes made, but to not save changes for power-up e <Z> Reset and save for power-up

For example, to enable Narrow Margins and reset without saving changes for power-up, send: <Ko1><A>.

To enable Narrow Margins and reset, saving the changes to non-volatile RAM, send: <Ko1><Z>.

Concatenating Serial Commands

Commands can also be concatenated (added together). For example, the following command, <Kc1><KA24><Ko1><A> enables LRC, sets the Host Protocol Response Timeout to 24 ms, enables Narrow Margins and resets the data buffers (without saving the changes for power-up).

A maximum of 64 characters can be concatenated in a single string or data block. Additional data blocks of 64 or less characters can be sent provided there is at least a 10 ms pause between blocks.

NOTE: Data in excess of 64 characters will reset the buffer, causing the first 64 characters of the string to be lost and indicator #1 to illuminate red 2 seconds after the end of each read cycle, until the scanner’s memory is reset.

Resetting the Parameters to Default Values

Assigning a Multidrop address to a scanner or making changes to communications parameters such as Baud Rate, Parity, Stop Bits, LRC, etc. without corresponding changes in linked device(s) can result in the loss of menu access. If this should occur, default the scanner.

(See “Defaulting the Scanner” in chapter 2, “Setup and Installation.)

Trigger Filter Timing Value

Format: <KF?

Returns current trigger filter timing value in milliseconds. Call your Microscan representative for additional information. (Not available in the menu configuration program.)

Series 4000 Raster Scanner User's Manual 3-49

Page 83 read from a scan by OCR; it may hold reading errors

Chapter 3 Configuration

Communications.

NOTE: Changes made in the scanner to communications parameters such as baud rate, parity, stop bits, LRC, etc., must be matched in the other device(s) or communications will be lost. If this occurs, default the scanner as described in chapter 2.

Protocol

If selecting one of the options from 0 to 4 (Point-to-Point, Point-to-Point with RTS/CTS, Point-to-Point with XON/XOFF, Point-to-Point with XON/ XOFF and RTS/CTS, or Polling Mode D), use this format:

Format: <KfdataA> Data A (protocol options):

0 = Point-to-Point Example: 1 = Point-to-Point with RTS/CTS To change the Protocol to 2 = Point-to-Point with XON/XOFF

Polling Mode D, send: <Kf4>. 3 _ Boint-to-Point with XON/KOFF and RTS/CTS 4 = Polling Mode D 5 = Multidrop (requires address) 6 = User Defined 7 = User Defined Multidrop lf selecting Multidrop (5), you must define an address and add it to the format (data B).

Format: <KfdataA,dataB> Data A (protocol option 5): Example: Data B (address):

To change the Protocol to Multidrop with an Any number from address of 33, send: <Kf5,33>. 1 to 50.

3-50 Series 4000 Raster Scanner User's Manual