Menu Configuration

Serial Data

The scanner accepts an ASCII character from the host or controlling device as a trigger to start a read cycle.

Serial Data & Edge

The scanner accepts either an external trigger or a serial ASCII] command to start a read cycle.

Press CR at the desired setting. Press SP to advance to End Of Read Cycle.

End of Read Cycle

Allows the user to choose what event will end the read cycle. The read cycle is the time during which the scanner will receive and process label data. When the Triggering Mode option is set in an External or Serial mode of operation, the trigger event initiates the read cycle.

NOTE: When operating in Continuous Read or Continuous Read 1 Output, the scanner is always in the read cycle.

Timeout is enabled by default. Options are Timeout, New Trigger, and Timeout & New Trigger. To change End of Read Cycle, press CR to see,

OPERATIONS -> END OF READ CYCLE = TIMEOUT -> TIMEQUT

Press SP to scroil through the options.

Timeout

Can end the read cycle after a specified period of time, and if no label has been read, causes a noread message, if enabled, to be transmitted.

With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout ends the read cycle.

With External Level enabled, the read cycle does not end until the falling edge trigger occurs, and the next read cycle does not begin until the next rising edge trigger.

With Continuous Read 1 Output enabled, a timeout initiates a new read cycle and allows the same label to be read again.

Series 4000 Raster Scanner User’s Manual 3-21

Page 55 read from a scan by OCR; it may hold reading errors

a

Chapter 3 Configuration

New Trigger

Ends the read cycle at the occurrence of a new trigger event, and if no label has been read, causes a noread message, if enabled, to be transmitted at the occurrence of the new trigger event.

With either External Edge, Serial Data, or Serial Data & Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle.

With External Level enabled, a falling edge trigger ends a read cycle. However, the next read cycle does not begin until the occurrence of the next rising edge trigger.

Timeout & New Trigger

Ends the read cycle after a specified period of time or at the occurrence of new trigger event, and if no label has been read, causes a noread message, if enabled, to be transmitted.

With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout, or an edge or serial trigger, whichever comes first, ends the read cycle. An edge or serial trigger also initiates a new read cycle.

With External Level enabled, the read cycle does not end until the occurrence of a falling edge, and the next read cycle does not begin until the next rising edge trigger.

Press CR to enable the desired option. Press SP to advance to Timeout in 10 ms incs.

Timeout Allows the user to define the duration of the timeout period. The default value is 100 (which is equal to one second). To change the timeout period, at the prompt,

OPERATIONS -> TIMEOUT in 10 ms incs = 100

Press CR. Enter a number from 0 to 65535. This number is derived by multiplying the required number of seconds times 100.

Press CR to enable. Press SP to advance to Serial Trigger Character.

3-22 Series 4000 Raster Scanner User’s Manual

Page 56 read from a scan by OCR; it may hold reading errors

Menu Configuration

Serial Trigger Character

Allows the user to define a single ASCII character as the host serial trigger character that initiates the read cycle. The serial trigger is considered an online host command and requires the same command format as all host commands (that is, to be entered within the < > brackets).

The default character is an ASCII GS (1DH), displayed on the terminal screen as <SOH>. The prompt displayed on the command line is 4].

NOTE: When selecting a trigger character, ensure that the selected character is not a NUL (00H) and is not used for other host commands or online protocol characters. For example, if an upper case D is assigned as a serial trigger character, a <D> command will no longer launch the menu program. (See chapter 4, “Operational Commands,” for a list of operational commands used by the scanner and appendix B for a list of ASCII characters.)

To change the serial trigger character, press CR, enter the new trigger character, and press CR to enable.

Press SP to advance to External Trigger Polarity.

External Trigger Polarity

Allows the user to determine whether a positive or negative transition will initiate the read cycle. When using a Microscan-supplied object detector, use the default (Positive) trigger polarity.

External Trigger Polarity is Positive by default. To change the selection to Negative, press CR, SP, and CR again. Press SP to advance to Noread Message.

Noread Message (user defined)

Allows the user to define any combination of ASCII characters (except a NUL) up to seven characters as the noread message.

The noread message, if enabled and if no bar code label has been decoded, will be transmitted to the host at a timeout or the end of a read cycle.

The default message is NOREAD.

To change Noread Message, press CR, enter the new message (up to seven characters), and press CR to enable.

Press SP to advance to Noread Message (enable/disable).

Series 4000 Raster Scanner User’s Manual 3-23

Page 57 read from a scan by OCR; it may hold reading errors

Chapter 3 Configuration

Noread Message (enable/disable) Allows the user to enable or disable the noread message. Noread Message is enabled by default. To disable Noread Message, press CR, SP, and CR. Press SP to advance to Bar Code Output.

Bar Code Output

Allows the user to choose whether or not to send label data (or noreads) to the host.

Bar Code Output is enabled by default.

When disabled, a label is decoded and the read cycle transpires as usual, but neither label data nor the noread message is transmitted to the host. All scanner counters are updated, and the number of good reads or noreads can be obtained via operational commands.

To disable, press CR, SP, and CR. Press SP to advance to When To Output.

When to Output (bar code label)

Allows the user to choose when bar code data is sent to the host. As Soon As Possible is enabled by default. Options are As Soon As Possible and End Of Read Cycle.

As Soon As Possible

Causes bar code data (good reads) to be transmitted immediately upon a good decode.

End of Read Cycle Causes bar code data output to be delayed until the end of the read cycle. To change When to Output to End of Read Cycle, press CR, SP, and CR. Press SP to advance to # of Reads Before a Good Decode.

3-24 Series 4000 Raster Scanner User's Manual

Page 58 read from a scan by OCR; it may hold reading errors

Menu Configuration

Number of Reads Before a Good Decode

Allows the user to select the number of good reads (from 71 to 31) required per label before a good decode output.

# of Reads Before a Good Decode is set to 1 by default.

NOTE: Be sure that the value set is within the determined scan rate for the scanning setup so that the scanner is capable of scanning a label the required number of times.

To change, press CR, enter a number from 1 to 31, and press CR. Press SP to advance to Match Code.

Match Code

Identical to <E> Enter Match Code Option in chapter 4.

When in a triggered mode, allows the user to enter a master label into the scanner’s memory to be compared with subsequently scanned labels.

Match Code is disabled by default. With Match Code enabled, a master label can be entered in three ways:

1. Toggling pin 25 to ground (pin 7) enables the next good read to be the master label

2. Sending serial command <G> enables the next good read to be the master label

3. Sending serial command <)XXXX)> (Master data label entered in place of the Xs.)

Figure 3-9 shows the sequence of operation (and reference) for setting up and entering master labels. See also “New Master Pin” and table 3-1, “Relay Driver Options/Outputs,” later in this section under “User Outputs.”

NOTE: If Match Code is enabled with Continuous Read, the scanner defaults to Continuous 1 Output mode, and the label data must change before the scanner will output data again, unless a timeout, if enabled, occurs.

NOTE: Enabling Match Code when Number of Labels is set to any number greater than one, will cause Number of Labels to default back to one.

To enable Match Code, press CR, SP, and CR. Press SP to advance to Number Of Labels.

Series 4000 Raster Scanner User's Manual 3-25

Page 59 read from a scan by OCR; it may hold reading errors

a

Chapter 3 Configuration

Match Code Enable New Master Pin (by menu or serial (by menu or serial command <Kn1> or <E>) command <Kz1>)

Toggle pin 25 to GND (pin 7) on host connector to enter next label scanned as Master Label

Serial Command <G> to enter next label scanned as Master Label

Read in Master Label

Compare

Master Label with subsequent labels

Serial Command | <)XXXX)> to download data as Master Label

See Relay Driver in the User Outputs menu for possible outputs

Figure 3-9 Match Code Logic Diagram

Number of Labels

Sometimes referred to as “multiple labels,” this option allows the user to select the number of labels from one to six that the scanner can read during one read cycle. The multiple labels can be a mix of any enabled bar code symbologies and more than one label can be decoded per scan line. The following restrictions apply to this command:

1. Each label, to be read, must be different.

2. The maximum number of characters in any one label is 31.

3. The maximum number of characters in a single scan line is 62. The default number for Number of Labels is One. Options are One, Two, Three, Four, Five, and Six.

To change Number of Labels, press CR, scroll to the new option, and press CR.

3-26 Series 4000 Raster Scanner User’s Manual

Page 60 read from a scan by OCR; it may hold reading errors

Menu Configuration

Press SP to advance to Field Separator.

NOTE: Enabling Match Code or Continuous Read 1 Output when Number of Labels is set to any number greater than one, will cause Number of Labels to default back to one.

Field Separator Inserts a separator character between each label. The default character for Field Separator is a comma (,).

Any ASCII character may be used, except a NUL.

To change the separator character, press CR, enter the new character, and press CR.

Press M to return to the Main menu.

Series 4000 Raster Scanner User’s Manual 3-27

Page 61 read from a scan by OCR; it may hold reading errors

Chapter 3 Configuration

Code Types Menu

From the Main menu, press SP to advance to the Code Types prompt. Press CR to see the Code Types menu (figure 3-10):

( - CURRENT SETTINGS FOR CODE TYPES \

CODE 339 ! CODABAR | I120F 5 | UPC | CODE 128 | | 1 | | CODE TYPE | ENABLED | DISABLED | DISABLED | DISABLED | DISABLED | FIXED LENGTH | DISABLED | DISABLED | N/A | N/A | DISABLED | CODE LENGTH #1 | 10 | 10 | 10 | N/A | 10 | CODE LENGTH #2 | N/A | NA | 6 | NA | N/A | CHECK DIGIT | DISABLED | N/A | DISABLED | N/A | N/A | C/D OUTPUT | DISABLED | N/A | DISABLED | N/A | NAA | INTERCHAR GAP | DISABLED | DISABLED | N/A | NA | NA | S/S MATCH | N/A | ENABLED | N/A | NAA 1 N/A | $/S OUTPUT | N/A | ENABLED | N/A | NA | NA | EAN | N/A | N/A | N/R ] DISABLED | N/A | SUPPLEMENTALS [| N/A | N/A | N/A { DISABLED | WN/A | NARROW MARGINS | DISABLED | DISABLED | DISABLED | DISABLED | DISABLED |

ESC = MAIN MENU OR EXIT N = NEXT ITEM

M = PREVIOUS MENU SP = NEXT ITEM

B = PREVIOUS ITEM CR = THIS ITEM

\ cone TYPES- - > NARROW MARGINS = DISABLED /

Figure 3-10 Code Types Menu

This menu allows the user to choose among the various bar code types and define their parameters.

The first command line for the Code Types menu is: CODE TYPES - - > NARROW MARGINS = DISABLED

Press SP from the Narrow Margins prompt to scroll through the five bar code types.

The Code Types menu is arranged in table format. Pressing CR at any of the code types will display its current status. From this point use SP to scroll through the available options (listed in the first column) for that code type. Options can be defined for any bar code type whether or not the bar code itself is enabled at the time.

Press M to resume scrolling through the code type options. See figure 3-11 for menu structure.

NOTE: Options listed in the command line do not necessarily appear in the same order as those posted in the first column of the menu.

3-28 Series 4000 Raster Scanner User’s Manual

Page 62 read from a scan by OCR; it may hold reading errors

“2

Menu Configuration

Code Types NOTE Bold text represents ) default settings. Narrow Margins Disabled Enabled ] I i | Code 39 Codabar 1! 2o0f5 UPC Code 128 F Status ~ Status - Status - Status - Status Enabled t Disabled Disabled Disabled Disabled Disabled Enabled Enabled Enabled Enabled - Check Digit - Start & Stop - Check - EAN - Fixed Code b Disabled Match Digit Disabled Length Enabled L Enabled Disabled Enabled Disabled Disabled naple Enabled - Check Digit Start & Stop - Check Digit ~ Supplementals, Code Length Output Output Output Disabled 10 Disabled Enabled Disabled Enabled User Enabled Disabled Enabled Required Definable - Large Large - Code Length #1 [ - Separator interchar Gap interchar Gap 10 Enabled Disabled Disabied User Disabled Enabled Enabled Definable + Fixed Code ~ Fixed Code - Code Length #2. & Separator Length Length 6 ; Disabled Disabled | User User Enabled Enabled Definable Definable, Code Length ~ Code Length 10 10 User User Definable Definable

Figure 3-11 Code Types Menu Structure

Series 4000 Raster Scanner User's Manual

3-29

Page 63 read from a scan by OCR; it may hold reading errors

Chapter 3 Configuration

Narrow Margins

Allows the scanner to read bar codes with quiet zones less than 10 times the narrow-bar-width. Quiet zone is a term used to describe the minimum space at the leading and trailing ends of a label. Each quiet zone can be as small as five times the narrow bar element when Narrow Margins is enabled.

Narrow Margins is disabled by default. To enable, press CR, SP, and CR. - Press SP to advance to Code 39.

Code 39 Code 39 is enabled by default. Press CR to display the following on the command line: CODE TYPES, > CODE 39 ~-> STATUS = ENABLED

To disable, press CR, SP, and CR. Press SP to advance to the first Code 39 item, Check Digit.

Check Digit

Code 39 is self-checking and does not normally require a check digit. However, for additional data integrity, a Modulus 43 check digit can be added to the bar code message.

Check Digit is disabled by default.

With Check Digit and an External or Serial trigger option enabled, an invalid check digit calculation will cause a noread message to be transmitted at the end of the read cycle.

To enable, press CR, SP, and CR. Press SP to advance to Check Digit Output.

Check Digit Output

When enabled, the check digit character is sent along with the label data. When disabled, label data will be sent without the check digit.

Check Digit Output is disabled by default.

In Disabled mode, a good read will output the label data but not the check digit character.

3-30 Series 4000 Raster Scanner User's Manual