12 Terminal Contents Terminal Window........................................................................................................................ 12-2 Find ............................................................................................................................................ 12-3 Send ........................................................................................................................................... 12-4 Macros........................................................................................................................................ 12-5 Terminal Window Menus............................................................................................................ 12-6

This section describes the Terminal window and macro functions in ESP.

MS-4 Imager User Manual

12-1

Page 292

Terminal Window

Terminal Window To use ESP’s Terminal, click on the Terminal button:

You will see this window: Clear screen

Copy, paste, save

Macros listed on this bar

Type text here to find matching text in the Terminal window.

Terminal screen

Click on Macros arrow to Add Macro, Remove Macro, or Edit Macro.

Type serial commands here.

Click on desired Macro to run.

The Terminal screen allows you to send serial commands to the Imager by using Macros, by copying and pasting, or by typing commands in the Send text field. The Terminal screen also displays symbol data or information from the Imager. You can also right click on the Terminal screen to bring up a menu of further options. 12-2

MS-4 Imager User Manual

Page 293

Terminal

Find The Find function allows you to enter text strings to be searched for in the Terminal window. For example, a series of symbols have been scanned into the Terminal view and you want to determine if a particular symbol whose data begins with “ABC” has been read. 1. Type “ABC” into the Find box.

2. Press Enter. The first instance of “ABC” will be highlighted in the Terminal window. 3. Click the Find button to the right of the text field to locate additional instances of “ABC”.

MS-4 Imager User Manual

12-3

Page 294

Send

Send The Send function allows you to enter serial commands and then send them to the imager. • Type the command into the Send box.

• Press Enter. • Click the Send button to the left of the text field to send .

12-4

MS-4 Imager User Manual

Page 295

Terminal

Macros Macros can be stored in a macro selection bar, edited in a separate window, and executed by clicking on the macro name.

Click on Next Row to see the next row of macros

Click on the first arrow here to see Add Macro or Default Macros. When you default macros, the entire macros set is restored to their original macro commands.

Click on subsequent arrows to edit macros.

When you click on the macro name, the macro is executed in the Terminal window. If this is a command, it is sent to the reader at the same time that it is displayed.

Editing a Macro When you click the arrow next to any macro and select Edit, the following appears:

You can edit an existing macro or type in the Macro Name text field and define it in the Macro Value text field. Click OK.

MS-4 Imager User Manual

12-5

Page 296

Terminal Window Menus

Terminal Window Menus Right-click on the Terminal window to display the following menu: • Copy selected text to clipboard. • Paste from Terminal or other text. • Clear all text in Terminal window. • Select All text in the Terminal window. • Save... brings up a Save As dialog. • Change Font... of text in Terminal; brings up a Font dialog. • Change Echo Font... to change typed text; brings up a Font dialog. • Enable Echo enables Echo text (typed by user). • Change Background Color of Terminal window. • Non-Printable Characters allows you to hide non-printable characters, or to show them in Standard or Enhanced format. • Default Settings returns all the above settings to default. • Keyboard Macros allows you to create new keyboard macro commands that can be sent from function keys (F2, F4, F5, etc.)

Terminal Dropdown Menu

The dropdown Terminal menu has Capture Text, Save Current Text, Send File, Find Next, and Find Previous functions, as well as the same functions defined above. • Capture Text... lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened. You can select Pause to interrupt the capture flow or Stop to end the flow and open the file. • Save Current Text... saves all text in the Terminal window to a text file. • Send File allows you to browse for specific files and send them to the reader. • Find Next searches for a user-defined section of text in the Terminal. • Find Previous operates in the same way as Find Next, but searches backward through Terminal text.

12-6

MS-4 Imager User Manual

Page 297

13 Utilities Contents Serial Utility Commands ............................................................................................................. 13-2 Read Rate .................................................................................................................................. 13-4 Counters ..................................................................................................................................... 13-5 Device Control ............................................................................................................................ 13-7 Master Database ........................................................................................................................ 13-8 Firmware................................................................................................................................... 13-14 Bar Code Configuration ............................................................................................................ 13-17 Default / Reset / Save............................................................................................................... 13-18 Imager Status Requests ........................................................................................................... 13-20 Other Operational Serial Commands ....................................................................................... 13-22

Utility commands are generally commands that are performed during Imager operations to check or determine read rates, or to perform miscellaneous operations on Imager hardware. Serial utility commands are not prefaced with a “K” and a numeric code, nor do they require an initialization command (<A> and <Z>). They can be entered from within any terminal program or from ESP’s Terminal or Utilities windows.

MS-4 Imager User Manual

13-1

Page 298

Serial Utility Commands

Serial Utility Commands Type Read Rate

Counter Request and Clear

Master Database

Part Number / Checksum

Device Control

Default/Reset/Save

Command <C> <Cp> <J> <N> <O> <T> <U> <V> <W> <X> <Y> <G> <Gn> <NEWM> <#> <#a> <#b> <#p> <!> <!a> <!b> <!p> <L1> <L2> <L3> <11> <10> <I> <H> <a1> <A> <Ard> <Arp> <Arc> <Z> <Zc>

13-2

Name Enter Decode Rate Test Enter Percent Rate Test Exit Decode Rate and Percent Rate Test No Read Counter No Read Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Store Next Symbol Read to Database Index 1 Store Next Symbol Read to Database Index n New Master Load Status Display All Firmware Part Numbers Display Application Code Part Number Display Boot Code Part Number Display Profile Module Part Numbers Display All Available Firmware Checksums Display Application Code Code Checksum Display Boot Code Checksum Display Profile Module Checksum Programmable Output 1 Programmable Output 2 Programmable Output 3 Targeting System On Targeting System Off Disable Imager Enable Imager Include PDF Information in Preamble (PDF417) Reset (does not save for power-on) Reset and Recall Microscan Defaults Reset and Recall Power-On Parameters Reset and Recall Customer Default Parameters Save Current Settings for Power-On Save Current Settings as Customer Default Parameters for Power-On MS-4 Imager User Manual

Page 299

Utilities Default/Reset/Save

<Zrd> <Zrc>

Imager Status Request Commands

Other Operational Commands

MS-4 Imager User Manual

<?> <K?> <K??> <K?#> <Knnn?> <Knnn??> <Knnn?#> <uy,path,filename> <dy,path,filename> <op,9> <@CAL> <BCCFG> <VAL>

Recall Microscan Default Parameters and Save for Power-On Recall Customer Default Parameters and Save for Power-On Imager Status Byte All Status Request All Descriptor Status Request All Range Status Request Single Status Request Single Descriptor Status Request Single Range Status Request Y-Modem Upload Transfer Options Y-Modem Download Transfer Options Image Library Request Autocalibrate Enter Bar Code Configuration Static Validation

13-3

Page 300

Read Rate

Read Rate Read Rate by ESP You can access Read Rate from the Utilities menu under the Read Rate tab. To see the number of decodes per second, click the Decodes/sec radio button and click the Start button. To see the percentage of decodes, click the Percent radio button and then the Start button. To end a read rate test, click the Stop button (the Start button becomes a Stop button during an active read rate test.)

Read Rate by Serial Command Enter Decodes / Second Test Sending <C> instructs the Imager to transmit the decodes per second and symbol data (if any). The decode rate can vary dramatically due to the angle and location of the symbol in relation to the field of view. This test is very useful in aligning and positioning the Imager during setup.

Enter Percent Test Sending <Cp> instructs the Imager to transmit the percentage of decodes and any decoded symbol data.

End Read Rate Test

Sending <J> ends both the Percent test and the Decodes/Second test.

13-4