Page 301
Utilities
Counters Counter commands can be a numeric value from 00000 to 65535. After reaching the maximum numeric limit of 65535, an error message will be displayed and the counter will automatically roll over and start counting again at 00000. To obtain the cumulative total of counts after the rollover has occurred, add 65536 per each rollover (the Imager does not keep track of the number of rollovers) to the current count. Note: All counter values will be lost if power is recycled to the Imager, or if the Imager receives a Reset or Save command.
Counters by ESP You can access Counters from ESP’s Utilities menu. Click the Request button to display the appropriate count or Clear to set the counter to zero.
MS-4 Imager User Manual
13-5
Page 302
Counters by Serial Command No Read Counter Sending <N> displays the total number of No Reads that have occurred since the last reset.
No Read Counter Reset Sending <O> sets the No Read Counter to 00000.
Trigger Counter Sending <T> displays the total number of triggers since the last reset.
Trigger Counter Reset Sending <U> sets the trigger counter to 00000.
Good Read / Match Counter (or Good Read Counter) Sending <V> displays the total number of good reads matching the master symbol, or, if Master Symbol is not enabled, the number of good reads since the last reset. This counter is always enabled, but will only work as a match count when Master Symbol is enabled. If Master Symbol is not enabled, this counter records the number of good reads. This count can be requested at any time.
Good Read / Match Counter Reset Sending <W> sets the Match Counter to 00000.
Mismatch Counter Sending <X> displays the number of decoded symbols since the last reset that do not match the master symbol.
Mismatch Counter Reset Sending <Y> sets the Mismatch Counter to zero.
13-6
MS-4 Imager User Manual
Page 303
Utilities
Device Control Device Control by ESP
Device Control by Serial Command Output 1 Pulse Sending <L1> activates the link between Output 1 (+) and Output 1 (-) of the host connector (regardless of Master Symbol or Output 1 status).
Output 2 Pulse Sending <L2> activates the link between Output 2 (+) and Output 2 (-) of the host connector (regardless of Master Symbol or Output 2 status).
Output 3 Pulse Sending <L3> activates the link between Output 3 (+) and Output 3 (-) of the host connector (regardless of Master Symbol or Output 3 status).
Disable Imager Sending <I> will turn the Imager OFF, end the current read cycle, and will not allow the Imager to enter another read cycle until turned ON. This feature is useful during extended periods of time when no symbols are being decoded, or the Imager is being configured. Disabling the Imager will not affect any commands that have already been downloaded.
Enable Imager Sending <H> will turn the Imager ON and allow it to enter read cycles.
Enable PDF Information Sending <a1> will cause PDF417 data to be prefaced with information consisting of error correction level (ECC level n), number of rows (n rows), number of columns (n columns), number of informative code words (n info code words), and the number of data characters (n data bits). Send <a1> again to disable PDF Information. MS-4 Imager User Manual
13-7
Page 304
Master Database
Master Database Important: The Master Database is used for all Matchcode modes except Sequential and Wild Card, both of which use Master Database Index # 1.
Master Database Overview Usage: Definition:
Used where more than one master symbol is required, as in a Multisymbol setup, for matching and other Matchcode operations. Allows the user to define up to 10 master symbols as the master symbol database, which can be entered by keyboard, scanned in, displayed, or deleted by serial or ESP commands.
1. Click the Master Database tab. 2. Enable Matchcode Type. 3. Set the Master Symbol Database Size. 4. Select the database index in which you want to enter the master symbol. 5. Do one of the following to enter master symbol data: a. Double-click the index row to type data directly into the index. b. Click the Read Symbol into Selected Index to enter the next decoded symbol. Set Master Symbol Database Size here.
Double-click a row to enter data into popup dialog box.
13-8
Loads the next symbol decoded into the selected index.
Loads the Imager’s saved master symbols into ESP.
Saves the displayed database to the Imager.
MS-4 Imager User Manual
Page 305
Utilities
Master Symbol Database Size Definition: Serial Cmd: Default: Options:
Number of Master Symbols allows you to select 1 to 10 master symbols for the master symbol database. <K231,master symbol database size> Note: You must follow this command with a save command <A> or <Z>. 1 1 to 10
Set Master Symbol Database Size here.
Caution: Since the total number of characters available for the master symbol database is 3000, changes to the Master Symbol Database Size will re-allocate the number of characters available for each master symbol and could cause existing master symbols to be deleted (except master symbol #1, unless it also exceeds the size limitation). The table below specifies the maximum number of characters available to each symbol according the number of master symbols defined, from 1 to 10. Master Symbol Number #1 #2 #3 #4 #5
MS-4 Imager User Manual
Maximum Characters 3000 1500 1000 750 600
Master Symbol Number #6 #7 #8 #9 # 10
Maximum Characters 500 428 375 333 300
13-9
Page 306
Master Database
Enter Master Symbol Data Allows you to enter master symbol data for any enabled master symbol index number (1 to 10), provided the total number of characters does not exceed the maximum allowed. Serial Cmd: <K231,master symbol number,master symbol data> Options: Enter data for 1 to 10 symbols (any combination of ASCII text up to the maximum allowed. For example, to enter data for master symbol 9, after making certain that master symbol database size is enabled for 9 or more symbols, send <K231,9,data>. Important: The ASCII characters <, >, and , can only be entered as hex pairs. See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values. Caution: If no data is entered, the existing data will be deleted. ESP: 1. Open the Utilities menu. 2. Set the number of master symbols you want to create in Master Symbol Database Size. 3. Double-click on each symbol number you want to set up and copy, or type your data in the popup dialog and click OK. Usage:
4. When all your data has been entered, click the Send Database to the Reader button.
13-10
MS-4 Imager User Manual
Page 307
Utilities
Request Master Symbol Data Definition:
Serial Cmd:
Returns master symbol data for any enabled master symbols from 1 to 10. For example, to request master symbol # 5, enter <K231?,5>. The Imager transmits master symbol # 5 data in brackets in the following format: <5/>. If no master symbol data is available, the output will be: <5/>. <K231?,master symbol number> Caution: Be sure to add the ? or you will delete the master symbol. Note: This command returns the number of master symbols if no number is included.
ESP:
1. Click the Utilities button and the Master Database tab. 2. Click the Receive Reader’s Database button.
Request All Master Symbol Data Definition: Serial Cmd:
This command will return master symbol data for all symbols enabled (up to 10). <K231?>
MS-4 Imager User Manual
13-11
Page 308
Read Next Symbol as Master Symbol Definition: Serial Cmd:
ESP:
After you’ve set the size in the database, you can order the Imager to read the next symbol as the master symbol for any given master symbol number. <Gmaster symbol number> To store the next symbol decoded as master symbol # 1, send: <G> or <G1>. To store the next symbol decoded as the master symbol for any other master symbol database number, send: <Gmaster symbol number [1-10]>. For example, <G5> will cause the next symbol read to be entered as master symbol # 5. In the Master Database tab under the Output Format menu, 1. Select the master symbol index number in which you want to store the symbol data. 2. Click the Read Symbol into Selected Index button. Caution: If you’ve selected an index which already has existing data, that data will be copied over by new decoded data when you use this command.
Request New Master Status Usage: Definition: Serial Cmd:
Informs the user when a new master symbol is pending and which position it is in. Returns the position in the master symbol database that will be loaded on the next read. <NEWM> The Imager returns: <NEWM/next master to load> Once a symbol has been read and loaded, the status will be cleared and the response will be <NEWM/0>.
(See also New Master Pin in Chapter 9, Matchcode.)
13-12
MS-4 Imager User Manual
Page 309
Utilities
Delete Master Symbol Data Definition: ESP:
You can directly delete the master symbol data by serial command or by ESP. 1. Click the Utilities button to access the master symbol. 2. Click the Master Database tab and double-click the symbol number you want to delete.
Serial Cmd:
3. Delete text and click OK. <K231,master symbol number,> To delete a master symbol, enter the database number and a comma, but leave the data field empty. For example, to delete master symbol # 5, send the following: <K231,5,>. The command is entered with a blank master symbol data field, which tells the Imager to delete the selected master symbol from the database.
MS-4 Imager User Manual
13-13
Page 310
Firmware
Firmware Firmware by ESP
Firmware Update Application code versions are specific to your Imager. Consult with your sales representative before downloading application code. If needed, an application code will be sent to you in the form of a *.mot file. To download application code: 1. First, be sure that your Imager is connected to the host. 2. Apply power to the Imager. 3. Before updating, you should verify the current firmware. 4. Click in the Firmware Update text box and select the file type you want to download. This will open a file locator box. 5. Navigate to the appropriate file (it will be a *.mot file) and open the file. Caution: Do not interrupt power or disconnect the host cable while download is in progress. Be sure that each download is complete before moving on to the next. Important: When updating firmware, be sure that the application code and boot code versions are mutually compatible.
13-14
MS-4 Imager User Manual