Page 141

Symbologies

Large Intercharacter Gap (Codabar) Definition:

Serial Cmd: Default: Options:

When disabled, the spaces between characters, or the “inter-character gap”, are ignored during the decode process. Note: If the inter-character space is large enough to be considered a margin, the symbol will not decode, regardless of this parameter’s setting. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (Codabar) Definition:

Serial Cmd: Default: Options:

When disabled, the Imager will accept any Codabar symbol provided it doesn’t exceed the system’s maximum capabilities. When enabled, the Imager will reject any Codabar symbol that doesn’t match the fixed length. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled

Symbol Length (Codabar) Definition: Serial Cmd: Default: Options:

This is the value against which all Codabar symbol lengths will be compared. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> 10 1 to 64

MS-4 Imager User Manual

6-19

Page 142

Codabar

Check Digit Type (Codabar) Definition:

Serial Cmd: Default: Options:

When disabled, the Imager will not perform any character checking calculations on decoded Codabar symbols. When set to Mod 16, the Imager will perform a modulus 16 check character calculation on the symbol. If the symbol does not pass this calculation, it will not be decoded. When set to NW7, The Imager will perform an NW7 modulus 11 check character calculation on the symbol. If the symbol does not pass this calculation, it will not be decoded. When set to Both, the Imager will perform both the Mod 16 and NW7 modulus 11 check character calculations on the symbol. If the symbol does not pass either calculation, it will not be decoded. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Disabled 0 = Disabled 1 = Mod 16 2 = NW7 (Mod 11) 3 = Mod 16 and NW7

Check Digit Output (Codabar) Definition:

Serial Cmd: Default: Options:

6-20

When this field is disabled and a check digit calculation is enabled, the Imager will strip the verified check digit from the symbol data output. This condition must be accounted for if a fixed length is also being used. When enabled, the Imager will output the check character as part of the symbol data. This condition must be accounted for if a fixed length is also being used. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled

MS-4 Imager User Manual

Page 143

Symbologies

UPC / EAN Usage:

Definition:

Serial Cmd: Default: Options:

Used primarily in POS application in the retail industry. It is commonly used with Microscan readers in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length, numeric, continuous symbology. UPC can have two- or five-digit supplemental bar code data following the normal code. The UPC Version A (UPC, A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the Imager will read UPC Version A and UPC Version E only. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled

1 = Enabled

EAN Status Usage: Definition:

Serial Cmd: Default: Options:

EAN is the European version of the UPC symbology and is used in European market applications. Note: UPC must be enabled for EAN to take effect. EAN is a subset of UPC. When enabled, the Imager will read UPC Version A, UPC Version E, EAN 13, and EAN 8. It also appends a leading zero to UPC Version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC Version A symbols is not desired, disable EAN. Note: The extra character identifies the country of origin. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled

MS-4 Imager User Manual

1 = Enabled

6-21

Page 144

UPC / EAN

Supplementals Status (UPC / EAN) Usage: Definition: Serial Cmd: Default: Options:

Reads Supplementals typically used in publications and documentation. A supplemental is a 2 to 5 digit symbol appended to the main symbol. When set to Enabled or Required, the Imager reads supplemental code data that has been appended to the standard UPC or EAN codes. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled 2 = Required

Disabled UPC Supplementals will not be decoded.

Enabled When enabled, the Imager will try to decode a main and a supplemental. However, if a supplemental is not decoded, the main will be sent by itself at the end of the read cycle.

Required When set to Required, both the main and the supplemental symbols must be read or a single No Read condition results. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character. Then the data is displayed as: MAIN * SUPPLEMENTAL. Note: Under no circumstances will the supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Symbols should be set accordingly.

Separator Status (UPC / EAN) Usage: Definition: Serial Cmd: Default: Options:

6-22

Allows users to distinguish between the main and Supplemental symbols. A character can be inserted between the standard UPC or EAN symbology and the supplemental symbology when Supplementals is set to Enabled or Required. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled

1 = Enabled

MS-4 Imager User Manual

Page 145

Symbologies

Separator Character (UPC / EAN)

Note: If Separator Character has been changed to any other character and you wish to redefine the separator as a comma, you will need to use ESP. Usage: Definition: Serial Cmd: Default: Options:

As required by the application. Allows the user to change the separator character from a comma to a new character. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> , (comma) Any ASCII character.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K473h,,,,,3C> For >: <K473h,,,,,3E> For , : <K473h,,,,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values. Note: Whenever Separator Character is defined as a comma (,) sending a <K473,s?> command will return the current settings, including the separator character comma which appears after the separator status comma.

Supplemental Type (UPC / EAN) Usage: Definition: Serial Cmd: Default: Options:

As required by symbology used in application. Allows the user to select 2 character or 5 character supplements, or both. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Both 0 = Both 1 = 2 characters only 2 = 5 characters only

Both

Either 2 character or 5 character supplementals will be considered valid.

2 Characters Only

Only two character supplementals will be considered valid.

5 Characters Only

Only five character supplementals will be considered valid.

MS-4 Imager User Manual

6-23

Page 146

UPC / EAN

Format UPC-E as UPC-A (UPC / EAN) Definition:

Serial Cmd: Default: Options:

6-24

When disabled, the Imager will output the version E symbols in their encoded 6-character format. When enabled, the Imager will format the symbol as either a 12-character UPC-A symbol or an EAN-13 symbol, depending on the state of the EAN status parameter. This formatting reverses the zero suppression that is used to generate the symbol in the UPC specification. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled

MS-4 Imager User Manual

Page 147

Symbologies

GS1 DataBar (RSS) DataBar Expanded Usage: Definition:

Serial Cmd: Default: Options:

Used to encode primary and supplementary data in retail point-of-sale and other applications. DataBar Expanded is a variable length symbology that can encode supplementary information in addition to the 14-digit EAN item identification number and is capable of encoding up to 74 numeric or 41 alphabetic characters. <K484,status,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled (non-stacked) 2 = Enabled (stacked and non-stacked)

Where appropriate, use 1 (non-stacked) for better performance over 2 (stacked and nonstacked).

Fixed Symbol Length Status (DataBar Expanded) Definition: Serial Cmd: Default: Options:

When enabled, the Imager will check the symbol length against the symbol length field, minus the embedded check digit. If disabled, any length would be considered valid. <K484,status,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (DataBar Expanded) Usage: Definition: Serial Cmd: Default: Options:

Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the Imager will recognize (this does not include start, stop, and check digit characters). The Imager ignores any symbol not having the specified length. <K484,status,fixed symbol length status,fixed symbol length> 14 1 to 74

MS-4 Imager User Manual

6-25

Page 148

GS1 DataBar (RSS)

DataBar Limited Usage: Definition: Serial Cmd: Default: Options:

DataBar Limited is designed to be read by laser and CCD readers. It is not recommended for omnidirectional slot scanners. Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional. <K483,status> Disabled 0 = Disabled 1 = Enabled

DataBar-14 Usage:

Used in the grocery, retail, and prescription drug industries where 14-digit EAN item identification may be needed.

Definition:

DataBar-14 (Reduced Space Symbology) is a fixed symbol length symbology that encodes 14 digits, including a 1-digit indicator. DataBar-14 is 96 modules wide. It can be stacked in two rows, it can read omnidirectionally if printed in full height, or horizontally if height-truncated for small marking. <K482,status> Disabled 0 = Disabled 1 = Enabled (non-stacked) 2 = Enabled (stacked; decode both stacked and non-stacked)

Serial Cmd: Default: Options:

Note: Where appropriate, use 1 (non-stacked) for better performance over 2 (stacked; decode both stacked and non-stacked).

6-26

MS-4 Imager User Manual

Page 149

Symbologies

PDF417 Usage:

Definition:

Serial Cmd: Default: Options:

Used in applications where a large amount of information (over 32 characters) needs to be encoded within a symbol, typically where the symbol is transported from one facility to another. For example, an automobile assembly line might use a single symbol with multiple fields of information that will be read at several stations along the way, without reference to a database. A two-dimensional, multi-row (3 to 90), continuous, variable length symbology that has high data capacity for storing up to 2,700 numeric characters, 1800 printable ASCII characters, or 1100 binary characters per symbol. Each symbol character consists of 4 bars and 4 spaces in a 17-module structure. <K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> Disabled 0 = Disabled

1 = Enabled

Note: Sending <a1> will cause PDF417 data to be prefaced with information consisting of error correction level (ECC Level n), number of rows (n Rows), number of columns (n Columns), number of informative code words (n Info Code Words) and the number of data characters (n Data Characters). This feature can be disabled by re-sending <a1>.

Fixed Symbol Length Status (PDF417) Serial Cmd: Default: Options:

<K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> Disabled 0 = Disabled

1 = Enabled

Fixed Symbol Length (PDF417) Usage: Definition: Serial Cmd: Default: Options:

Used to increase data integrity by ensuring that only one symbol length will be accepted. When enabled, the PDF symbol must contain the same number of characters as the symbol length setting before it can be considered a good read. The Imager will ignore any symbol not having the specified length. <K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> 10 1 to 2710

Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.

MS-4 Imager User Manual

6-27

Page 150

PDF417

Codeword Collection (PDF417) Usage: Definition:

Serial Cmd: Default: Options:

6-28

Multiple Codeword Collection is useful in applications where portions of subsequent images can be read and pieced together so that no opportunity or time is lost to assemble codewords for decoding. When set to Multiple, PDF codewords are collected from multiple images and assembled throughout the read cycle until the read cycle ends or the symbol is fully decoded. It is important to note that when this feature is enabled, only one PDF symbol should be presented to the Imager per read cycle. <K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> Single Image 0 = Single Image