Page 131

Symbologies

Full ASCII Set (Code 39) Usage:

Definition:

Serial Cmd: Default: Options:

Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) The user must know in advance whether or not to use the Full ASCII Set option. Since Full ASCII Set requires two code words to encode one character, it is less efficient. Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign, and percent symbol. When Full ASCII Set is enabled, the Imager can read the full ASCII character set, from 0 to 255. <K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Disabled 0 = Disabled

MS-4 Imager User Manual

1 = Enabled

6-9

Page 132

Code 128 / EAN 128

Code 128 / EAN 128 Usage: Definition: Serial Cmd: Default: Options:

Code 128 is a smaller symbology useful in applications with tight spots and high security needs. A very dense alphanumeric symbology. It encodes all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled

1 = Enabled

Fixed Symbol Length Status (Code 128 / EAN 128) Definition: Serial Cmd: Default: Options:

When enabled, the Imager will check the symbol length against the symbol length field. If disabled, any length will be considered a valid symbol. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled

1 = Enabled

Fixed Symbol Length (Code 128 / EAN 128) Usage: Definition: Serial Cmd: Default: Options:

6-10

Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. This specifies the exact number of characters that the Imager will recognize (this does not include start, stop, and check digit characters). The Imager ignores any symbol not having the specified length. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> 10 1 to 64

MS-4 Imager User Manual

Page 133

Symbologies

EAN 128 Status (Code 128 / EAN 128) Definition:

Serial Cmd: Default: Options:

When this field is disabled, the Imager will not check any Code 128 labels for conformance to EAN requirements, or perform any special formatting. When enabled, the Imager can read symbols with or without a function 1 character in the first position. If a symbol has a function 1 character in the first position, it must conform to EAN format. Symbols that conform to EAN format will also be subject to the special output formatting options available in this command. Note: Code 128 status must be enabled for EAN status to be active. If EAN status is required, the Imager will only decode symbols that have a function 1 character in the first position and that conform to EAN format. All symbols read will be subject to the special output formatting options available in this command. Note: Code 128 status must be enabled for EAN status to be active. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled 2 = Required

Output Format (Code 128 / EAN 128) Definition:

Serial Cmd: Default: Options:

In Standard, the Imager will not apply special EAN output formatting options. In Application, the Imager will apply the special EAN output formatting options to decoded EAN-conforming symbols. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Standard 0 = Standard

1 = Application

Application Record Separator Status (Code 128 / EAN 128) Definition: Serial Cmd: Default: Options:

When enabled, an EAN separator will be inserted into the output between fields whenever an EAN-conforming symbol is decoded and EAN output formatting applies. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled

MS-4 Imager User Manual

1 = Enabled 6-11

Page 134

Code 128 / EAN 128

Application Record Separator Character (Code 128 / EAN 128) Definition: Serial Cmd:

This is an ASCII character that serves as an EAN separator in formatted EAN output. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding>

Default:

,

Options:

Any ASCII character (7 bit).

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K474h,,,,,,,3C> For >: <K474h,,,,,,,3E> For , : <K474h,,,,,,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.

Application Record Brackets (Code 128 / EAN 128) Definition: Serial Cmd: Default: Options:

If an EAN-conforming symbol is decoded and EAN formatting applies, this feature places bracket characters “( )” around the application identifiers in the formatted output. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled

1 = Enabled

Application Record Padding (Code 128 / EAN 128) Definition: Serial Cmd: Default: Options:

6-12

This feature causes the Imager to pad variable-length application fields with leading zeroes. This is not done for the last field of a symbol. <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status, output format,application record separator status,application record separator character,application record brackets,application record padding> Enabled 0 = Disabled

1 = Enabled

MS-4 Imager User Manual

Page 135

Symbologies

BC412 Usage:

Definition:

Serial Cmd: Default: Options:

Widely used in semiconductor manufacturing. Particularly useful where speed, accuracy, and ease of printing are required. BC412 (Binary Code 412), a proprietary IBM symbology since 1988, is an alphanumeric symbol with a set of 35 characters, each encoded by a set of 4 bars in 12 module positions. All bars have a single width; it is the presence (1) or absence (0) of bars in each of the twelve module positions that make BC412 binary. This symbology is also bi-directional and self-clocking, with a start character and a stop character. <K481,status,check digit output,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled

1 = Enabled

Check Digit Output (BC412) Usage: Definition: Serial Cmd: Default: Options:

Check Digit Output, added to the symbol, provides additional security. When enabled, the check digit character is read and compared along with the symbol data. When disabled, symbol data is sent without the check digit. <K481,status,check digit output,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled

1 = Enabled

Fixed Symbol Length Status (BC412) Definition: Serial Cmd: Default: Options:

When enabled, the Imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid. <K481,status,check digit output,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled

1 = Enabled

Fixed Symbol Length (BC412) Definition: Serial Cmd: Default: Options:

When enabled, the check digit character is read and compared along with the symbol data. When disabled, symbol data is sent without the check digit. <K481,status,check digit output,fixed symbol length status,fixed symbol length> 10 1 to 64

MS-4 Imager User Manual

6-13

Page 136

Interleaved 2 of 5

Interleaved 2 of 5 Usage:

Definition:

Serial Cmd: Default: Options:

I-2/5 has been popular because it is the most dense symbology for printing numeric characters less than 10 characters in length; however, Microscan does not recommend this symbology for any new applications because of inherent problems such as truncation. A dense, contimuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check digit is highly recommended). Important: You must set Symbol Length in order to decode I-2/5 symbols, unless Range Mode is enabled. <K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,guard bar status,range mode status> Disabled 0 = Disabled

1 = Enabled

Check Digit Status (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:

This option is not typically used, but it can be enabled for additional security in applications where the host requires redundant check digit verification. An error correcting routine in which the check digit character is added. <K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,guard bar status,range mode status> Disabled 0 = Disabled

1 = Enabled

Check Digit Output Status (Interleaved 2 of 5) Definition: Serial Cmd: Default: Options:

6-14

When enabled, a check digit character is sent along with the symbol data for added data security. <K472,status,check digit status,check digit output status,symbol length #1,symbol length #2,guard bar status,range mode status> Disabled 0 = Disabled

1 = Enabled

MS-4 Imager User Manual

Page 137

Symbologies

Symbol Length #1 (Interleaved 2 of 5) Useful in applications where I 2/5 symbols of a specific length are required. The Symbol Length # 1 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. Serial Cmd: <K472,status,check digit status,check digit output,symbol length #1,symbol length #2,guard bar status,range mode status> Default: 10 Options: 0 to 64, even only. Important: If Range Mode is disabled, the length of the symbol must match either Symbol Length # 1 or Symbol Length # 2 to be considered a valid symbol. If Range Mode is enabled, Symbol Length # 1 and Symbol Length # 2 form a range into which the length of the symbol must fall to be considered valid. Usage: Definition:

Symbol Length #2 (Interleaved 2 of 5) Useful in applications where I 2/5 symbols of a specific length are required. The Symbol Length # 2 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. Serial Cmd: <K472,status,check digit status,check digit output,symbol length #1,symbol length #2,guard bar status,range mode status> Default: 6 Options: 0 to 64, even only. Important: If Range Mode is disabled, the length of the symbol must match either Symbol Length # 2 or Symbol Length # 1 to be considered a valid symbol. If Range Mode is enabled, Symbol Length # 2 and Symbol Length # 1 form a range into which the length of the symbol must fall to be considered valid. Usage: Definition:

MS-4 Imager User Manual

6-15

Page 138

Interleaved 2 of 5

Guard Bar Status (Interleaved 2 of 5) Note: Whenever Guard Bar is enabled, the presence of guard bars (also called “bearer bars”) is required for decoding to take place. Usage: Definition: Serial Cmd: Default: Options:

Useful when I-2/5 multisymbols are enabled to prevent false data output. This typically occurs with highly tilted or skewed symbols. A guard bar is a heavy bar, at least twice the width of the wide bar, surrounding the printed I-2/5 symbol and helping to prevent false reads. <K472,status,check digit status,check digit output,symbol length #1,symbol length #2,guard bar status,range mode status> Disabled 0 = Disabled

1 = Enabled

Range Mode Status (Interleaved 2 of 5) Usage: Definition:

Serial Cmd: Default: Options:

6-16

Useful in applications where I 2/5 symbols of a specific length are required. When Range Mode is disabled, the Imager checks the value of the symbol length against the values set in Symbol Length # 1 and Symbol Length # 2. If the symbol length does not match either of the preset values, then it is rejected as invalid. When Range Mode is enabled, Symbol Length # 1 and Symbol Length # 2 are combined to form a range of valid symbol lengths. Any symbol length that does not fall into this range is rejected as an invalid symbol. Either of the preset symbol length values in the Symbol Length # 1 and Symbol Length # 2 fields can form the start or end of the range. <K472,status,check digit status,check digit output,symbol length #1,symbol length #2,guard bar status,range mode status> Disabled 0 = Disabled

1 = Enabled

MS-4 Imager User Manual

Page 139

Symbologies

Code 93 Usage: Definition: Serial Cmd: Default: Options:

Sometimes used in clinical applications. Code 93 is a variable-length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces. <K475,status,fixed symbol length status,symbol length> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (Code 93) Definition:

Serial Cmd: Default: Options:

When disabled, the Imager will accept any Code 93 symbol provided is doesn’t exceed the system’s maximum capabilities. When enabled, the Imager will reject any Code 93 symbol that doesn’t match the fixed symbol length. <K475,status,fixed symbol length status,symbol length> Disabled 0 = Disabled 1 = Enabled

Symbol Length (Code 93) Definition: Serial Cmd: Default: Options:

This is the symbol length value against which all Code 93 symbols will be compared. <K475,status,fixed symbol length status,symbol length> 10 1 to 64

MS-4 Imager User Manual

6-17

Page 140

Codabar

Codabar Usage: Definition: Serial Cmd: Default: Options:

Used in photo-finishing and library applications. Previously used in medical applications, but not typically used in newer medical applications. Codabar is a 16-bit character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled

Start / Stop Match (Codabar) Definition:

Serial Cmd: Default: Options:

When disabled, the Imager will decode Codabar symbols whether or not the start and stop characters are the same. When enabled, the Imager will not decode Codabar symbols unless the start and stop characters are the same. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Enabled 0 = Disabled 1 = Enabled

Start / Stop Output (Codabar) Definition:

Serial Cmd: Default: Options:

6-18

When disabled, the start and stop characters will not be present in the data output of the decoded symbol. When enabled, the start and stop characters will be present in the data output of the decoded symbol. Note: Because the start and stop characters are included as part of the data, the characters must be included as part of the length in a fixed length mode of operation. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Enabled 0 = Disabled 1 = Enabled