Page 121
Read Cycle
Minimum Good Reads Definition: Serial Cmd: Default: Options:
This value specifies the number of times a symbol needs to be read to qualify as a good read. <K221,minimum good reads> 1 1 to 255
MS-4 Imager User Manual
5-25
Page 122
Setting Up the Imager for EZ Trax
Setting Up the Imager for EZ Trax If you are using EZ Trax software, it is important to set up the MS-4 correctly before beginning. Click the Read Cycle button to display the Read Cycle tree control.
Set Trigger Mode, <K200>, to External Edge.
Set Capture Mode, <K241>, to Rapid Capture.
Once these Read Cycle parameters are set, you will be ready to connect to EZ Trax. For a description of how to configure EZ Trax using serial commands or ESP, see Configuring EZ Trax Output in Chapter 7, I/O Parameters. For more detailed information about using EZ Trax, refer to the Help menu in EZ Trax software, or the EZ Trax Quick Start Guide, available on the Microscan Tools Drive. 5-26
MS-4 Imager User Manual
Page 123
6 Symbologies Contents Symbologies by ESP.................................................................................................................... 6-2 Symbologies Serial Commands ................................................................................................... 6-3 Data Matrix ................................................................................................................................... 6-4 QR Code ...................................................................................................................................... 6-6 Code 39........................................................................................................................................ 6-7 Code 128 / EAN 128 .................................................................................................................. 6-10 BC412 ........................................................................................................................................ 6-13 Interleaved 2 of 5........................................................................................................................ 6-14 Code 93...................................................................................................................................... 6-17 Codabar...................................................................................................................................... 6-18 UPC / EAN ................................................................................................................................. 6-21 GS1 DataBar (RSS) ................................................................................................................... 6-25 PDF417 ...................................................................................................................................... 6-27 MicroPDF417 ............................................................................................................................. 6-29 Composite .................................................................................................................................. 6-30 Narrow Margins / Symbology Identifier ...................................................................................... 6-31 Background Color....................................................................................................................... 6-33
This section describes the various symbol types that can be read and decoded by the MS-4 Imager. See the following sites for additional information about linear and 2D symbologies: http://www.aimglobal.org/standards/aimpubs.asp http://barcodes.gs1us.org/dnn_bcec/Default.aspx?tabid=82
MS-4 Imager User Manual
6-1
Page 124
Symbologies by ESP
Symbologies by ESP
Click this button to bring up the Symbologies menu.
To change a setting, double-click the setting and use your cursor to scroll through the options.
To open nested options, single-click the +.
6-2
MS-4 Imager User Manual
Page 125
Symbologies
Symbologies Serial Commands Narrow Margins/Symbology ID Background Color Composite Code 39 Codabar Interleaved 2 of 5 UPC/EAN Code 128/EAN 128
Code 93 PDF417 Data Matrix QR Code BC412 DataBar-14 DataBar Limited DataBar Expanded MicroPDF417
MS-4 Imager User Manual
<K450,narrow margin status,symbology identifier status> <K451,background color> <K453,symbology status,separator status,separator> <K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> <K472,status,check digit status,check digit output status,symbol length #1, symbol length #2, guard bar status,range mode status> <K473,UPC status,EAN status,supplemental status,separator status,separator character,supplemental type,format UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> <K475,status,fixed symbol length status,symbol length> <K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> <K479,ECC 200 status, ECC 000 status,ECC 050 status, ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> <K480,status> <K481,status,check digit output,fixed symbol length status,fixed symbol length> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,[unused],fixed symbol length status,fixed symbol length>
6-3
Page 126
Data Matrix
Data Matrix Usage: Definition:
Very useful where information needs to be packed into a small area, and/ or where symbols need to be applied directly to the substrate with laser etching, chemical etching, dot peen, or other methods. Data Matrix is a type of Matrix symbology and has subsets ECC 000 - ECC 200. ECC 200 symbols have an even number of rows and an even number of columns. Most of the symbols are square with sizes from 10x10 to 144x144. Some symbols, however, are rectangular, with sizes from 8x18 to 16x48. All ECC 200 symbols can be recognized by the upper right corner module being light (binary 0) instead of dark.
ECC 200 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 200 Data Matrix symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status, ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Enabled Note: This is the only symbol type enabled by default. 0 = Disabled
1 = Enabled
ECC 000 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 000 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status, ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
ECC 050 Definition: Serial Cmd: Default: Options:
6-4
When enabled, will decode ECC 050 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status, ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
MS-4 Imager User Manual
Page 127
Symbologies
ECC 080 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 080 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status, ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
ECC 100 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 100 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status, ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
ECC 140 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 140 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status, ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
ECC 120 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 120 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status, ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
1 = Enabled
ECC 130 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 130 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status, ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled
MS-4 Imager User Manual
1 = Enabled 6-5
Page 128
QR Code
QR Code Usage: Definition:
Serial Cmd: Default: Options:
6-6
Widely implemented in the automotive industry in Japan and throughout their worldwide supply chain. QR Code is capable of handling numeric, alphanumeric, and byte data as well as kanji and kana characters. Up to 7,366 characters (numeric data) can be encoded using this symbol. Therefore, less space is required to encode the same amount of data in a QR Code symbol than in a conventional symbol, lowering the cost of labelling. Three Position Detection Patterns in the symbol make omnidirectional, ultra-fast reading possible. QR Code has error protection capability. Data can often be restored even if a part of the symbol has become dirty or damaged. <K480,status> Disabled 0 = Disabled
1 = Enabled
MS-4 Imager User Manual
Page 129
Symbologies
Code 39 Usage: Definition: Serial Cmd: Default: Options:
Code 39 is considered the standard for non-retail 1D symbology. An alphanumeric symbology with unique start/stop code patterns, composed of 9 black and white elements per character, of which 3 are wide. <K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Disabled 0 = Disabled
1 = Enabled
Check Digit Status (Code 39) Serial Cmd: Default: Options:
<K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Disabled 0 = Disabled
1 = Enabled
Check Digit Output Status (Code 39) Usage: Definition:
Serial Cmd: Default: Options:
Check Digit Output Status, added to the symbol, provides additional data security. When enabled, the check digit character is read and compared along with the symbol data. When disabled, symbol data is sent without the check digit. Note: With Check Digit Output Status and an External or Serial trigger option enabled, an invalid check digit calculation will cause a No Read message to be transmitted at the end of the read cycle. <K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Disabled 0 = Disabled
MS-4 Imager User Manual
1 = Enabled
6-7
Page 130
Code 39
Large Intercharacter Gap (Code 39) Usage:
Definition: Serial Cmd: Default: Options:
Large Intercharacter Gap is helpful for reading symbols that are printed out of specification. Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled, because a large intercharacter gap (over 3x) could cause a narrow margin (5x) to be interpreted as an intercharacter gap. When enabled, the Imager can read symbols with gaps between symbol characters that exceed three times (3x) the narrow element width. <K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Disabled 0 = Disabled
1 = Enabled
Fixed Symbol Length Status (Code 39) Definition: Serial Cmd: Default: Options:
When enabled, the Imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid. <K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Disabled 0 = Disabled
1 = Enabled
Fixed Symbol Length (Code 39) Usage: Definition: Serial Cmd: Default: Options:
6-8
Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the Imager will recognize (this does not include start and stop and check digit characters). The Imager ignores any symbology that does not match the specified length. <K470,status,check digit status,check digit output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 10 1 to 64
MS-4 Imager User Manual