Page 151

Symbologies

MicroPDF417 Usage: Definition: Serial Cmd: Default: Options:

Used for labelling small items that need large data capacity. A variant of PDF417, a very efficient and compact stacked symbology that can encode up to 250 alphanumeric characters or 366 numeric characters per symbol. <K485,status,[unused],fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (MicroPDF417) Serial Cmd: Default: Options:

<K485,status,[unused],fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (MicroPDF417) Usage: Definition:

Serial Cmd: Default: Options:

Used to increase data integrity by ensuring that only one symbol length will be accepted. When enabled, the MicroPDF417 symbol must contain the same number of characters as the symbol length setting before it can be considered a good read. The Imager will ignore any symbol not having the specified length. <K485,status,[unused],fixed symbol length status,fixed symbol length> 10 1 to 366

Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.

MS-4 Imager User Manual

6-29

Page 152

Composite

Composite

When set to Enabled or Required, will attempt to decode the composite component of a linear symbol. The linear symbol can be DataBar-14, DataBar Expanded, DataBar Limited, EAN-128, UPC-A, EAN-13, EAN-8, and UPC-E. Usage: Definition: Serial Cmd: Default: Options:

Allows reading by both linear and 2D readers. Combines 2D and linear width modulated symbology on the same symbol where different messages can be read by each reader type. <K453,mode,separator status,separator> Disabled 0 = Disabled 1 = Enabled 2 = Required

Enabled

If set to Enabled, the Imager only decodes the linear component, and it will only output the linear component.

Required

If set to Required, the Imager must decode both the linear and the composite components; otherwise it outputs a No Read.

Separator Status (Composite) Usage: Definition: Serial Cmd: Default: Options:

Allows the user to distinguish between the main and Supplemental symbols. Separates the linear and the composite component. <K453,mode,separator status,separator> Disabled 0 = Disabled

1 = Enabled

Separator Character (Composite) Usage: Definition: Serial Cmd: Default: Options:

As required by the application. Allows the user to change the separator character from a comma to a new character. <K453,mode,separator status,separator> , (comma) Any ASCII character.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K453h,,,3C> For >: <K453h,,,3E> For , : <K453h,,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values. 6-30

MS-4 Imager User Manual

Page 153

Symbologies

Narrow Margins / Symbology Identifier Narrow Margins Usage: Definition:

Serial Cmd: Default: Options:

Used when the leading and trailing edges of the symbols are smaller than the standard margin or other objects encroach into the margins. Allows the imager to read 1D symbols with quiet zones less than 8 times the width of the narrow bar element. “Quiet zone” is the space at the leading and trailing ends of a symbol. Each quiet zone can be as narrow as only five times the width of the narrow bar element when Narrow Margins is enabled. <K450,narrow margins,symbology identifier status> 2D Enhanced 0 = Disabled 1 = Enabled 2 = 2D Enhanced

Note: Do not use Narrow Margins when Large Intercharacter Gap is enabled for Code 39.

Enabled

When Narrow Margins is set to Enabled, the imager uses a 5x margin requirement for standard linear symbols.

2D Enhanced

2D Enhanced enables a special decode algorithm for narrow-margin 2D symbols.

MS-4 Imager User Manual

6-31

Page 154

Narrow Margins / Symbology Identifier

Symbology Identifier Definition:

Serial Cmd: Default: Options:

Symbology Identifier is an ISO/IEC 16022 standard prefix set of characters that identifies the symbol type. When enabled, the imager analyzes and identifies the symbology and adds a three-character identifying prefix to the data: • ] (closed bracket character) indicating the presence of a symbology identifier. • A, C, E, F, G, I, L, Q, Y, b, d, e, p, z • (A = Code 39; C = Code 128; E = UPC/EAN; F = Codabar; G = Code 93; I = I-2/5; L = PDF417 and MicroPDF417; b = BC412; d = Data Matrix; e = GS1 DataBar (RSS) • Modifier Example: ]d indicates a Data Matrix symbol. <K450, narrow margins,symbology identifier status> Disabled 0 = Disabled 1 = Enabled

Explanation of Modifiers for Code 39, Codabar, and I-2/5

• For Code 39, Codabar, and I-2/5, the modifier indicates Check Character and Check Character Output status. • For Code 39 only, Full ASCII must be enabled to see modifiers 4, 5, and 7. Modifier

Check Character

0 1 3 4 5 7

Disabled Enabled Enabled Disabled Enabled Enabled

Check Character Output N/A Enabled Disabled N/A Enabled Disabled

Full ASCII conversion performed (Code 39 only) No No No Yes Yes Yes

Example: ]A5 indicates a Code 39 symbol with Check Character and Check Character Output enabled and Full ASCII conversion performed.

Explanation of Modifiers for Other Symbologies • For Code 128, a 1 indicates EAN 128; otherwise the modifier is 0. • For all other symbologies, the modifier is 0.

6-32

MS-4 Imager User Manual

Page 155

Symbologies

Background Color Usage: Definition: Serial Cmd: Default: Options:

Symbol backgrounds are often White, or other very light colors. If the background is darker than the symbol, Black background should be enabled. Allows the user to specify the symbol background used in the application. <K451,background color> Both 0 = White 1 = Black 2 = Both

White When White background is enabled, the bars of linear symbols and the elements of 2D symbols are recognized as dark on a light background.

Black When Black background is enabled, the bars of linear symbols and the elements of 2D symbols are recognized as light on a dark background.

Both When Both is enabled, the imager will attempt to decode for white background first, and if there is no decode, will then attempt to decode for black background.

MS-4 Imager User Manual

6-33

Page 156

Background Color

6-34

MS-4 Imager User Manual

Page 157

7 I/O Parameters Contents I/O Parameters by ESP ................................................................................................................ 7-2 I/O Parameters Serial Commands ............................................................................................... 7-3 Symbol Data Output ..................................................................................................................... 7-4 No Read Message........................................................................................................................ 7-6 Bad Symbol Message .................................................................................................................. 7-8 No Symbol Message .................................................................................................................... 7-8 1D / Stacked Symbology Qualification ......................................................................................... 7-9 2D Symbology Qualification ....................................................................................................... 7-10 Read Duration Output ................................................................................................................ 7-16 Output Indicators ........................................................................................................................ 7-17 Beeper........................................................................................................................................ 7-21 LED Configuration ...................................................................................................................... 7-22 Serial Verification ....................................................................................................................... 7-23 EZ Button ................................................................................................................................... 7-25 EZ Button Modes........................................................................................................................ 7-27 Configurable Output 1 ................................................................................................................ 7-29 Trend Analysis Output 1............................................................................................................. 7-32 ISO/IEC 16022 Symbol Quality Output 1 ................................................................................... 7-35 Diagnostic Output 1.................................................................................................................... 7-38 Configurable Output 2 ................................................................................................................ 7-39 Trend Analysis Output 2............................................................................................................. 7-39 ISO/IEC 16022 Symbol Quality Output 2 ................................................................................... 7-39 Diagnostic Output 2.................................................................................................................... 7-39 Configurable Output 3 ................................................................................................................ 7-40 Trend Analysis Output 3............................................................................................................. 7-40 ISO/IEC 16022 Symbol Quality Output 3 ................................................................................... 7-40 Diagnostic Output 3.................................................................................................................... 7-40 Power-On/Reset Counts ............................................................................................................ 7-41 Time Since Reset ....................................................................................................................... 7-42 Service Message........................................................................................................................ 7-43 Frame Information ...................................................................................................................... 7-44 Image Output.............................................................................................................................. 7-45 Database Identifier Output ......................................................................................................... 7-48 Quality Output ............................................................................................................................ 7-49 Configuring EZ Trax Output ....................................................................................................... 7-50

This section includes instructions on setting up conditions for changing input/output electrical transitions for control of the Imager’s internal and external devices. A discrete I/O (in/out) signal is an electrical transition from one voltage level to another so that digital switching can occur. MS-4 Imager User Manual

7-1

Page 158

I/O Parameters by ESP

I/O Parameters by ESP

Click this button to bring up the I/O menu.

To change a setting, double-click the setting and use your cursor to scroll through the options.

To open nested options, single-click the +.

7-2

MS-4 Imager User Manual

Page 159

I/O Parameters

I/O Parameters Serial Commands Power On/Reset Counts

<K406,power-on,resets,power-on saves,power-on flash saves>

Time Since Reset

<K407,hours,minutes>

Service Message

<K409,status,service message,threshold,resolution>

Serial Verification

<K701,serial command echo status,serial command beep status,control/hex output>

Beeper

<K702,status>

Quality Output

<K704,decodes/trigger separator,decodes/trigger status>

Symbol Data Output

<K705,symbol data output status,when to output>

Read Duration Output

<K706,status,separator>

No Read Message

<K714,status,message>

Bad Symbol Message

<K715,[unused],message>

No Symbol Message

<K716,[unused],message>

1D/Stacked Symbology Qualification

<K717,minimum number of bars,minimum number of qualified scan lines,start/stop status>

2D Symbology Qualification

<K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension status,dimension 1,dimension 2,dimension tolerance,orientation status,orientation value>

Frame Information

<K734,output frame number,output coordinates>

LED Configuration

<K737,LED mode,ISO/IEC 16022 grade>

Image Output

<K739,image output mode,communication port,file format,jpeg quality>

Target/Flood LEDs

<K750,green flash LED status,target pattern LED status,green flash duration>

EZ Trax Output

<K757,comm port,image mode,image format,jpeg quality,object info output,grade output>

Database Identifier Output

<K759,status,separator>

EZ Button

<K770,global status,default on power-on,load configuration database,save for power-on>

EZ Button Modes

<K771,single beep,two beeps,three beeps,four beeps> <K780,trend analysis mode,trigger evaluation period,number to output on>

Trend Analysis Output 1 Trend Analysis Output 2

<K781,trend analysis mode,trigger evaluation period,number to output on>

Trend Analysis Output 3

<K782,trend analysis mode,trigger evaluation period,number to output on>

Diagnostic Output 1

<K790,unused 1,servuce unit>

Diagnostic Output 2

<K791,unused 1,servuce unit>

Diagnostic Output 3

<K792,unused 1,servuce unit>

ISO/IEC 16022 Symbol Quality Output 1

<K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold>

ISO/IEC 16022 Symbol Quality Output 2

<K801,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold>

ISO/IEC 16022 Symbol Quality Output 3

<K802,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold>

Configurable Output 1

<K810,output on,output state,pulse width,output mode>

Configurable Output 2

<K811,output on,output state,pulse width,output mode>

Configurable Output 3

<K812,output on,output state,pulse width,output mode>

MS-4 Imager User Manual

7-3

Page 160

Symbol Data Output

Symbol Data Output Symbol Data Output Status Note: Symbol Data Output relates to data and should not be confused with Outputs 1, 2, and 3 listed in the Output Parameters which describe output states and functions. Usage: Definition: Serial Cmd: Default: Options:

Useful when the host needs symbol data only under certain conditions. Defines the conditions under which decoded symbol data is transmitted to the host. <K705,symbol data output status,when to output> Good Read 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read

Note: Symbol Data Output Status, if set to Match or Mismatch, will not take effect unless Matchcode Type is enabled and a master symbol is loaded into memory.

Disabled Usage:

Definition:

It is useful when an application only needs to use the discrete outputs and can allow the Imager to do the decision-making. When Disabled, the host does not need the symbol data and the communication lines are used only for setup and status checks. When set to Disabled, the Imager will not transmit any data that is generated during a read cycle (symbols, No Reads, etc.)

Match Usage: Definition:

Match is used in an application that requires specific symbol information and needs to sort, route, or verify based on matching the specific symbol data. When set to Match, the Imager transmits symbol data whenever a symbol matches a master symbol. However, if Matchcode Type is Disabled, it transmits on any good read.

Note: A No Read can still be transmitted if Enabled.

Mismatch Usage: Definition:

Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container. With Mismatch enabled, the Imager transmits symbol data whenever the symbol data information does NOT match the master symbol.

Note: A No Read can still be transmitted if Enabled. 7-4

MS-4 Imager User Manual