Page 211

MS-3 Laser E.book Page 19 Monday, August 30, 2004 11:09 AM

Chapter Appendices EOT STX ETX ACK NAK

^D ^B ^C ^F ^U

04 02 03 06 15

Reset Start of Text End of Text Acknowledge Negative Acknowledge

XON XOFF

^Q ^S

11 13

Begin Transmission Stop Transmission

MS-3 Laser Scanner User’s Manual

A-19

Page 212

MS-3 Laser E.book Page 20 Monday, August 30, 2004 11:09 AM

Defaulting/Saving/Resetting

Appendix G, Defaulting/Saving/Resetting Understanding and controlling your reader’s active, saved, and default settings is critical to the operation of your reader. Table A-12 Software Reset/Save/Recall Commands <A> <Ard> <Arp> <Arc> <Z> <Zc> <Zrd> <Zrc>

Reset (does not save for power-on) Reset and recall Microscan defaults Reset and recall power-on parameters Reset and recall customer default parameters Save current settings for power-on Save current settings as customer default parameters Recall Microscan default parameters and save for power-on Recall customer default parameters and save for power-on

Power-on Parameters Power-on parameters (saved by the <Z> command) are saved to NOVRAM and recalled and loaded into current parameters when power is cycled or the <Arp> command is issued.

Customer Default Parameters Customer default parameters (saved by <Zc> command) are the same set of parameters as power-on but are saved in a different, isolated section of NOVRAM. This can allow a user to essentially create a backup set of parameters that can be recalled in the event that the current parameters or power-on parameters have been changed and no longer desired. It is important to note that a hardware default does not affect these parameters. For example, a user that inadvertently changed communication settings in power-on parameters in such a way that they either don't know the settings or don't have the capability to communicate at those settings. By using the hardware default to default the power-on settings to the known Microscan default, the user can then recall their previously customer saved settings with the <Arc> or <Zrc> commands.

Default on Power-On You can also use the EZ button to default the reader to customer defaults and save for power-on by holding down the EZ button while applying power to the reader, provided that this feature is enabled in “Default on Power-On” on page 5-31. This is the same as the <Zrc> command.

A-20

MS-3 Laser Scanner User’s Manual

Page 213

MS-3 Laser E.book Page 21 Monday, August 30, 2004 11:09 AM

Chapter Appendices

Microscan Default Parameters Microscan defaults parameters are contained in the firmware that cannot be changed.

Software Defaults Microscan default parameters can be recalled (loaded into current settings) with <Ard> command or recalled and saved for power-on with the <Zrd> command.

Hardware Default If a software default reset is not possible, it may be necessary to reset the reader by shorting (connecting) specific pins. This procedure has the same effect as the <Zrd> software command. Important: For this reset to occur, this command must be executed within 60 seconds after a power-on or a reset. 1. Apply power to the reader. 2. If using an IB-131, locate pins 7 and 11 on the host connector (see Table A-1 on page A-4). Caution: Be certain that the correct pins are located. Connecting the wrong pins could cause serious damage to the unit. 3. Momentarily connect these wires (or pins) and listen for a series of short beeps. 4. Within 3 seconds, connect them again. A longer beep should be heard. If not, repeat the process.

Default/Reset Definitions Defaults are original or saved customer settings that can be recalled, either by software reset or hardware reset (“Hardware Default” on page A-21). Also when in multidrop, defaulting might be required if the scanner has been assigned a polling address and you wish to access the scanner’s menu. Defaulting the scanner by <Zrd> resets the configuration parameters to Microscan default values. Defaulting might be necessary if you have make temporary changes, communications between the reader and another device are lost or interrupted, or you are using incompatible equipment (for example, a terminal that is set at 38.4 K baud communicating with a reader that is set at 115.2 K baud).1 Resets (“A” commands) affect only the current settings (active memory) and are not saved for power on or recall. Active Memory is where the reader’s active settings are stored during use. These are not available on power-on unless saved by a “Z” command.

Hardware Default Access to the configuration menus of a scanner that is in a polled mode can be forced 1. There are no menu options or host commands for resetting the configuration program. MS-3 Laser Scanner User’s Manual

A-21

Page 214

MS-3 Laser E.book Page 22 Monday, August 30, 2004 11:09 AM

Defaulting/Saving/Resetting by sending a <D> command from an auxiliary terminal via the auxiliary RS-232 port, when enabled. Caution: Be certain that you short the correct pins. Shorting the wrong pins can cause serious damage to the unit.

Procedure: Important: You must complete the default within one minute after power-on. 1. Locate and mark the default pins or wires connecting to default pins. If using an IB-131 Interface, use pins 11 and 7 (figure A-2) on the HOST 25-pin connector. Results will be more consistent if you attach a push button switch. Pin 11

Pin 7

Figure A-2 Host Connector, 25-pin (on side of IB-131 box) 2. Turn power to the scanner ON. You should see the LED illuminators flash OFF and turn back ON, indicating a successful reset. 3. Momentarily short the default pins. Listen for a series of quick beeps, then short the default pins again. 4. You should hear a longer beep. If not, repeat the process.

A-22

MS-3 Laser Scanner User’s Manual

Page 215

MS-3 Laser E.book Page 23 Monday, August 30, 2004 11:09 AM

Chapter Appendices

Appendix H, PDF Symbology If you have a special model of the MS-3 that has PDF capability (FIS 0003-017 to 0003032), you will be able to access the PDF menu commands in ESP and send serial commands described here. Usage:

PDF is used in applications where a large amount of information (over 32 characters) needs to be encoded within a symbol, typically where the symbol is transported from one facility to another. For example, an automobile assembly line might use a single symbol with multiple fields of information that will be read at several stations along the way, without reference to a database.

Definition:

It is a two-dimensional, multi-row (3 to 90), continuous, variable length symbology that has high data capacity for storing up to 2700 numeric characters, 1800 printable ASCII characters, or 1100 binary character per symbol. Each symbol character consists of 4 bars and 4 spaces in a 17-module structure.

PDF417 Status Serial Cmd:

<K476,status,unused,fixed symbol length status,fixed symbol length,decode at end of read cycle>

Default:

Enabled

Options:

0 = Disabled

1 = Enabled

Fixed Symbol Length Status (PDF417) Usage:

Used to increase data integrity by ensuring that only one symbol length will be accepted.

Definition:

When enabled, the PDF symbol must contain the same number of characters as the symbol length setting before it can be considered a good decode. The scanner will ignore any symbol not having the specified length.

Serial Cmd:

<K476,status,unused,fixed symbol length status,fixed symbol length,decode at end of read cycle>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Fixed Symbol Length (PDF417) Definition:

Specifies the exact number of characters the scanner will recognize. Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.

MS-3 Laser Scanner User’s Manual

A-23

Page 216

MS-3 Laser E.book Page 24 Monday, August 30, 2004 11:09 AM

PDF Symbology Serial Cmd:

<K476,status,unused,fixed symbol length status,fixed symbol length,decode at end of read cycle>

Default:

10

Options:

1 to 2710

Decode at End of Read Cycle (PDF417) Definition:

When enabled, the decoding of the PDF symbol takes place after the End of Read Cycle requirements have been met. This allows the reader to accumulate information about the current PDF symbol present but not attempt to error correct or translate the information until the end of the read cycle.

Serial Cmd:

<K476,status,unused,fixed symbol length status,fixed symbol length,decode at end of read cycle>

Default:

Disabled

Options:

0 = Disabled

A-24

1 = Enabled

MS-3 Laser Scanner User’s Manual

Page 217

MS-3 Laser E.book Page 25 Monday, August 30, 2004 11:09 AM

Chapter Appendices

Related PDF Utility Commands PDF417 Info Output Command <a1> You can initiate an information output mode by sending the read the <a1> command. PDF-417 symbols read subsequent to this command will have a leading header of information about the decoded symbol. An example of the output for a ECC level 4 test symbol Microscan PDF-417 Test Symbol ECC Level 4 is as follows: ECC Level 4 20 Rows 3 Columns 28 Data Code Words 32 Error Correction Code Words 40 Encoded Data Bytes Microscan PDF-417 Test Symbol ECC Level 4

PDF-417 Code Word Output Command <a2> You can request the output of the PDF symbol’s code words decoded in the last triggered read cycle. There are two forms of data output: 1. The first stream of data output will be the symbol’s code words prior to a successful error correction and data translation. Erasures or missing code words are displayed with a “?” in place of the code word. 2. Following that will be the corrected or restored matrix of the symbol’s code words.

MS-3 Laser Scanner User’s Manual

A-25

Page 218

MS-3 Laser E.book Page 26 Monday, August 30, 2004 11:09 AM

Symbol Configuration

Appendix I, Symbol Configuration You can configure your scanner by presenting Code 128 symbols that the MS-3 scanner responds to as serial commands. Note: Your scanner does not need to be enabled for Code 128 in order to enter symbol configuration.

Entering Symbol Configuration The symbol used to enter configuration is the 7-character code 128 symbol shown below. It is not required that the scanner be configured to read code 128 symbols to read this start symbol or the following configuration symbols. To setup for symbol configuration: 1. Put the scanner in a read cycle mode. 2. Place a special Code 128 configuration start symbol in the scanners field of view. Use this symbol or one that you have created yourself.

If the scanner is able to read the start symbol, it will begin to beep and the performance LEDs will be activated. 3. When the scanner starts to beep, remove the configuration symbol from the scanner’s field of view. The beeping will end and the scanner will be in the configuration mode. During the configuration mode the LEDs will emit a side to side “Knight Rider” pattern to let you know you are currently ready to configure. You can create your own start symbol by encoding the following in Code 128: FNC4 <_CFG>.

Using Configuration Symbols Once in symbol configuration mode, serial command data encoded in Code 128 symbols is read by the scanner as serial input. Configuration symbols must meet the following conditions: 1. The only valid configuration symbols are Code 128. 2. Symbol data may contain more than one command, but individual symbols must be presented one at a time. This is because only the first symbol in a read cycle record will be used as a possible configuration symbol.

A-26

MS-3 Laser Scanner User’s Manual

Page 219

MS-3 Laser E.book Page 27 Monday, August 30, 2004 11:09 AM

Chapter Appendices 3. A symbol that is presented to the scanner must be read 25 times consecutively to be used as a valid symbol. Once this is done the scanner will interpret the symbol data in the same fashion as it interprets serial data. 4. Any valid command may be entered via symbols including operational commands. Because the data is treated like serial input multiple symbols may be used to represent one command as long as the symbols are presented individually and in the correct order. 5. Read rate command may also be used to enter read rate from symbol configuration mode. 6. When in read rate, the scanner will read the symbologies that were enabled prior to entering the configuration mode. However it will read a “<J>” in code 128 regardless of current enable/disable state of code 128. Once the <J> is issued the scanner exit both read rate and symbol configuration. To exit read rate and remain in symbol configuration, you present the start symbol once again. Symbols read in read rate will not configure the scanner. To start a read rate test, scan this symbol:

Exiting Symbol Configuration There are multiple ways of exiting symbol configuration. The first way is to simply read or serially enter the “<J>” command. Other ways include any command that executes a software reset. These commands include the save family as well as the reset family e.g. <Z>, <Zc>, <Zrd>, <Zrc>, <A>, <Arc> and <Ard>. When exiting symbol configuration with the symbol “<J>,” the scanner will beep in response. To end the read rate test and the symbol configuration program, scan this symbol:

This will terminate symbol configuration mode. Changes made in configuration will remain in effect just as would changes made in the menus or by serial commands.

MS-3 Laser Scanner User’s Manual

A-27

Page 220

MS-3 Laser E.book Page 28 Monday, August 30, 2004 11:09 AM

Object Detector

Appendix J, Object Detector In a typical operation, a reader will wait for symbol data only during a triggered read cycle. A read cycle is initiated by a “trigger” and can be in the form of a serial command from the host (internal trigger) or a signal from an object detector (external trigger). When an object detector (also called a sensor, package detector, etc.) is used, it is set up so that its beam will bounce off the approaching object and the resulting pulse will be sent to the reader to begin the read cycle. Typically, a detector is positioned so that it will detect the presence of an object before its symbol can be read. An object detector is mounted in almost any position relative to the object as long as (1) the object passes within range of the detector and (2) direct or reflected light from the detector does not interfere with the reader’s reception. As the item continues to move down the line, its symbol moves into the reader beam and is read by the reader.

Bar coded item

Object detector

Bar coded item

MS-3

Figure A-1 Object Detector

A-28

MS-3 Laser Scanner User’s Manual