Page 151
MS-3 Laser E.book Page 3 Monday, August 30, 2004 11:09 AM
Chapter 8 Diagnostics
Diagnostic Messages Overview Usage:
These messages serve as a flag to service a scanner or as an early warning that potential problems could arise. They are particularly useful in factories that run 24/7 and can’t afford down time.
Definition:
Warning messages that relate to the environment and condition of the scanner can be defined and set to activate specific outputs. Note: When enabled, the error condition will override all other operational modes configured for the output. When enabled, laser current and NOVRAM warning messages will be transmitted to the host or any active port whenever the pre-defined conditions are met.
MS-3 Laser Scanner User’s Manual
8-3
Page 152
MS-3 Laser E.book Page 4 Monday, August 30, 2004 11:09 AM
Counts
Counts (These commands are READ ONLY.) Sending <K406?> returns a four fields of data, as follows: <K406, power-on,resets,power-on saves,customer default saves>
Power-on Count Usage:
Useful for detecting unwanted resets caused by power supply problems or ESD transients.
Definition
Returns the number of times the scanner has been re-powered.
Serial Cmd:
Send <K406?> Returns < (read only)
Read Only Ranges:
0 to 65,535 powerups, 0 to 65,535 resets.
Resets Usage:
Useful for detecting unwanted resets caused by power supply problems or ESD transients.
Definition
Returns Resets for all the “warm” resets, including <A>, <Ard>, <Arp> and <Arc>.
Serial Cmd:
Send <K406?> Returns <K406, power-on,resets,power-on saves,custom default saves>
Read Only Ranges:
0 to 65,535 powerups, 0 to 65,535 resets.
8-4
MS-3 Laser Scanner User’s Manual
Page 153
MS-3 Laser E.book Page 5 Monday, August 30, 2004 11:09 AM
Chapter 8 Diagnostics
Power-on Saves Usage:
Useful for detecting unwanted resets caused by power supply problems or ESD transients.
Definition
Returns the number of times the scanner saves for the power-on resets, including <Z>, <Zc>, <Zrd>.
Serial Cmd:
Send <K406?> Returns <K406, power-on,resets,power-on saves,custom default saves>
Read Only Ranges:
0 to 65,535 powerups, 0 to 65,535 resets.
Customer Default Saves Usage:
Useful for detecting unwanted resets caused by power supply problems or ESD transients.
Definition
Returns the number of customer default saves: <Zrd>.
Serial Cmd:
Send <K406?> Returns <K406, power-on,resets,power-on saves,custom default saves>
Read Only Ranges:
0 to 65,535 powerups, 0 to 65,535 resets.
MS-3 Laser Scanner User’s Manual
8-5
Page 154
MS-3 Laser E.book Page 6 Monday, August 30, 2004 11:09 AM
Hours Since Last Reset
Hours Since Last Reset (This command is READ ONLY.) Usage:
Useful as a troubleshooting tool that can help pinpoint the cause of a reset.
Definition:
Records the number of hours and minutes of operation since the last system reset.
Serial Cmd:
Send <K407?> Returns <K407hours,minutes>
Read Only Ranges:
0 to 23 hours, 0 to 59 minutes.
8-6
MS-3 Laser Scanner User’s Manual
Page 155
MS-3 Laser E.book Page 7 Monday, August 30, 2004 11:09 AM
Chapter 8 Diagnostics
Laser High When enabled, a message is transmitted whenever the laser current exceeds a factorycalibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected.
Laser High Status Usage:
Alerts the user to impending laser failure. (Contact Service.)
Definition:
Enables the Laser High message.
Serial Cmd:
<K411,laser high status,laser high message,laser low status,laser low message>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Laser High Message Definition:
Defines the Laser High message.
Serial Cmd:
<K411,laser high status,laser high message,laser low status,laser low message>
Default:
HIGH-LASER
Options:
Any 1 to 10 character ASCII string except NUL, <, or >.
MS-3 Laser Scanner User’s Manual
8-7
Page 156
MS-3 Laser E.book Page 8 Monday, August 30, 2004 11:09 AM
Laser Low
Laser Low When enabled, a message is transmitted whenever the laser current falls below a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected.
Laser Low Status Usage:
Alerts the user to impending laser failure. (Contact Service.)
Definition:
Enables the Laser Low message.
Serial Cmd:
<K411,laser high status,laser high message,laser low status,laser low message>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
Laser Low Message Definition:
Defines the Laser Low message.
Serial Cmd:
<K411,laser high status,laser high message,laser low status,laser low message>
Default:
LOW-LASER
Options:
Any 1 to 10 character ASCII string except NUL, <, or >.
8-8
MS-3 Laser Scanner User’s Manual
Page 157
MS-3 Laser E.book Page 9 Monday, August 30, 2004 11:09 AM
Chapter 8 Diagnostics
Service Message Definition:
The service timer is reset on power-on, thus the timer only records the time that has elapsed since the last reset. The message is sent every time the timer expires.
Service Message Status Definition:
When enabled, a message is sent whenever the system detects that a user-set service time has expired.
Serial Cmd:
<K409,status,service message,threshold,resolution>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Service Message Serial Cmd:
<K409,status,service message,threshold,resolution>
Default:
SERVICE
Options:
Any 1 to 10 ASCII characters except NULL < , or >.
Threshold Definition:
Sets the number of hours or minutes that will transpire before the Service message is output.
Serial Cmd:
<K409,status,service message,threshold,resolution>
Default:
300 (5 minutes)
Options:
1 to 65,535
Resolution Definition:
Records time in seconds or minutes.
Serial Cmd:
<K409,status,service message,threshold,resolution>
Default:
Seconds
Options:
0 = Seconds
1 = Minutes
MS-3 Laser Scanner User’s Manual
8-9
Page 158
MS-3 Laser E.book Page 10 Monday, August 30, 2004 11:09 AM
Service Message
8-10
MS-3 Laser Scanner User’s Manual
Page 159
MS-3 Laser E.book Page 1 Monday, August 30, 2004 11:09 AM
Chapter
Calibration
9 Chapter Contents Calibration ...................................................................................................9-2 Auto Frame..................................................................................................9-6
The purpose of calibration is to optimize certain scanner settings to obtain the highest read rates in one or several label positions as required by the user’s application. This section includes the overall steps in calibration and specific steps for calibration by ESP, serial command, and embedded menus. For most applications, calibration is the only optical setup required. This section also includes an explanation of Auto Frame commands, the routine for constraining the width of the scan beam.
MS-3 Laser Scanner User’s Manual
9-1
Page 160
MS-3 Laser E.book Page 2 Monday, August 30, 2004 11:09 AM
Calibration
Calibration When a Calibrate command is sent, all symbologies are enabled except PDF4171 and Pharmacode.2 The scanner looks for readable bar code symbols, and records the highest read rates it encounters while stepping through various settings for motor speed, laser power, fixed gain, and AGC level. If the The software evaluates the results and selects the best combination.
Setting up for Calibration Position your bar code symbol at the distance used in your application and confirm that it is at a distance within the specifications for that symbol size (see “Position Symbol and Scanner” on page 1-4).
Calibration Methods There are three ways to start calibration: • ESP Calibration menu (page 9-3). • Serial command <@CAL> (page 9-3). • From the embedded calibration menu <@> (page 9-4).
1. Calibration does not function with PDF417 symbols. However, you can substitute a Code 128 symbol with the same mil size as your PDF417. When you do this, enable Code 128 and after calibration, switch back to PDF417. 2. Note: If using an I 2 of 5 label, verify that the number of characters in the label being scanned matches the code length enabled for the I 2 of 5 code type (default is 10 and 6). See “Interleaved 2 of 5” on page 5-13.
9-2