2 Using ESP Contents EZ Mode........................................................................................................................................2-2 Application Mode...........................................................................................................................2-3 Menu Toolbar ................................................................................................................................2-4 Autoconnect ................................................................................................................................2-12 View ............................................................................................................................................2-14 Navigating in ESP .......................................................................................................................2-15 Send/Receive Options ................................................................................................................2-16
This section is designed to help you understand the basic structure and elements of ESP (Easy Setup Program). When you open ESP, unless otherwise specified in the ESP Preferences dialog accessible from the Options heading on the menu toolbar, you will enter EZ Mode for initial setup. From there, you can enter Application Mode (App Mode) and access three configuration menus (Communications, Read Cycle, and Symbologies), a Terminal interface, and a Utilities interface. ESP can be used to configure the MS-2 CCD Reader in three main ways: • Tree Controls: Each configuration menu contains a list of all option settings that pertain to that specific element of reader operation. For example, the Communications menu shows a Host Port Connections option, and then a list of the sub-options Baud Rate, Parity, Stop Bits, and Data Bits. Each of these sub-options is configurable by using dropdown menus. • Graphic User Interfaces: Reader settings can be configured using such point-and-click tools as radio buttons, zoom in/zoom out sliders, spin boxes, check boxes, and drag-and-drop functions. • Terminal: ESP’s Terminal allows you to send serial configuration and utility commands directly to the reader by typing them in the provided text field. Information about using ESP in specific applications is provided in subsequent sections. For ESP system requirements, see System Requirements for ESP in Chapter 1, Quick Start.
MS-2 CCD Reader User’s Manual
2-1
Page 22
EZ Mode
EZ Mode EZ Mode offers instructions on positioning the reader in relation to a test symbol, and also features an Autodiscriminate function that automatically enables all symbologies.
Enter App Mode to access configuration trees and other setup features.
If you are unsure what type of symbology you are using, click Autodiscriminate to enable all symbologies.
2-2
MS-2 CCD Reader User’s Manual
Page 23
Using ESP
Application Mode From EZ Mode, you can click on the App Mode button to access specific configuration menus, Utilities tools, Camera setup, Output Format options, and a Terminal window where serial commands can be entered.
Note: The App Mode and EZ Mode buttons appear in the same position to allow easy switching between these primary modes. Click this icon to return to EZ Mode.
Menu toolbar.
Click here to open the Terminal or Utilities views.
Click on icons in this row to access configuration trees like the one shown below.
Click the Configuration icon to return to full App Mode view from Terminal or Utilities.
Note: See the corresponding sections in this manual for specific information on any of the views or modes mentioned above.
MS-2 CCD Reader User’s Manual
2-3
Page 24
Menu Toolbar
Menu Toolbar File > New Whenever New is selected, the default configuration of ESP is loaded.
Open/Save When Save or Save As is selected, the ESP configuration is saved to the host computer’s hard drive and available whenever the same file is selected under Open. Important: When you save menu changes to your hard drive, these changes are not saved to your reader. The illustration below shows how settings can be saved and received between ESP and the reader, and ESP and the host hard drive.
(Save to Reader) (Receive Reader Settings)
Import/Export Import converts the ASCII settings from a text file to ESP configuration settings. Export converts the active ESP configuration settings to an ASCII text file.
2-4
MS-2 CCD Reader User’s Manual
Page 25
Using ESP
Model In the Model menu you can select any of the models supported by ESP. When you choose a different model, the connection to your present model will be terminated.
To connect to another model, select New Model, choose a new model from the pop-up menu that appears, and click OK. Note: When you save an ESP file, you are saving the settings of all the models defined in that file.
MS-2 CCD Reader User’s Manual
2-5
Page 26
Menu Toolbar
Options The Options menu allows you to save memos and set up ESP Preferences. Note: Preferences will be saved and loaded into ESP whenever ESP is opened next, whether or not you save the ESP file.
Preferences > General Tab
The Toolbar Style options allow you to determine how ESP will display the mode options in the two rows at the top of the screen.
Reload Last File At startup, reloads the last file saved to the host computer’s hard drive.
Show Model Prompt At startup, shows the model menu displaying all supported readers.
Show Connect Prompt At startup, displays the Would you like to connect to the MS-2? prompt.
Receive After Connect At startup, loads the reader’s settings into ESP. (This is not recommended if you want to preserve your ESP settings for future use.)
Skip EZ Mode At startup, skips EZ Mode and opens directly in App Mode.
2-6
MS-2 CCD Reader User’s Manual
Page 27
Using ESP
Preferences > Terminal Tab
Show Non-Printable Characters When Show Non-Printable Characters is enabled, characters such as “CRLF” will be displayed in the Terminal window. When Enhanced Format is checked, the characters are displayed with more detailed formatting.
Change Keyboard Macros Clicking the Change Keyboard Macros button brings up the Function Keys dialog. In this dialog you can select the desired function key and then enter your macro keystrokes in the associated key map. For example, to make Ctrl-F2 the keystroke to send a trigger character, select F2, then in the Ctrl row, enter <trigger character> and click OK. Then whenever the Ctrl-F2 keystroke is pressed, the trigger character will start the read cycle. Note: The F1 key is reserved for opening ESP Help and the F3 key is reserved for the Find Next function.
Change Font Allows you to modify the font used for decode data received from the reader on the Terminal screen.
Change Echo Font Allows you to modify the font used for command characters typed into the Terminal view.
Enable Echo Allows you to enter command characters in Terminal.
Display Incoming Data Even When Not in Focus When Display Incoming Data Even When Not in Focus is enabled, data from the reader will continue to appear in the Terminal even when ESP is not the top window. MS-2 CCD Reader User’s Manual
2-7
Page 28
Menu Toolbar
Preferences > Bar Code Options Tab
The Bar Code Options dialog allows you to set the size of user-created symbols.
Sizing Information Sets the bar width or module width (in mils, or thousandths of an inch) of user-created symbols. Example: A bar width of 14 is 0.014 inches.
Caption Allows you to define and position a human-readable caption for the symbol you create.
2-8
MS-2 CCD Reader User’s Manual
Page 29
Using ESP
Preferences > Advanced Tab
Send XON with Autoconnect Sends an XON (Begin Transmission) command to the reader before starting the Autoconnect routine.
Ask to Save ESP File when Quitting When enabled, prompts the user to save a .esp file when ending a session.
The .esp file will be saved in the location of your choice.
MS-2 CCD Reader User’s Manual
2-9
Page 30
Menu Toolbar
Preferences > Advanced Tab (cont.) Connect to Readers via TCP/IP When enabled, shows a TCP/IP option on the Select Protocol dialog. Note: This option should only be selected if you intend to connect using an Ethernet adapter.
Use Default Storage Location When enabled, automatically stores data in ESP’s Application Data folder.
2-10
MS-2 CCD Reader User’s Manual