Page 11
1 Quick Start Contents Step 1 Check Hardware................................................................................................................ 1-2 Step 2 Connect the System .......................................................................................................... 1-3 Step 3 Install ESP ......................................................................................................................... 1-4 Step 4 Select Model...................................................................................................................... 1-5 Step 5 Autoconnect....................................................................................................................... 1-6 Step 6 Position the Reader ........................................................................................................... 1-7 Step 7 Configure the Reader ....................................................................................................... 1-8 Step 8 Save Configuration in ESP ................................................................................................ 1-9
This section is designed to get your MS-2 CCD Reader up and running quickly using ESP (Easy Setup Program). Following these steps will allow you to get a sense of the reader’s capabilities and to test symbol decode performance. Detailed setup information for installing the reader into your application can be found in the subsequent sections.
MS-2 CCD Reader User’s Manual
1-1
Page 12
Check Hardware
Step 1, Check Hardware Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.
USB Hardware Item Description 1 MS-2 CCD Reader 2 IC-3USB Interface Kit
Part Number FIS-0002-000XG 98-000051-01
USB Hardware Required
RS-232 Hardware Item Description 1 MS-2 CCD Reader 2 IC-332 Adapter 3 IB-131 Interface Box Power Supply (90-264 4 VAC, 24VDC, USA/Euro plug) 5 Object Detector 6 Communication Cable
Part Number FIS-0002-000XG FIS-0001-0035G 99-000018-01 97-100004-15 99-000017-01 61-300026-03 RS-232 Hardware Required
1-2
MS-2 CCD Reader User’s Manual
Page 13
Quick Start
Step 2, Connect the System Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.
Connecting by USB • Connect the reader (1) to the IC-3USB Interface Kit (2). • Connect the IC-3USB Interface Kit (2) to the host computer. The reader is powered by the USB connection.
USB Hardware Configuration
Connecting by RS-232 • Connect the reader (1) to the IB-131/IC-332 interface (2) and (3). • Connect the host cable (6) to the host and to the host port on the IB-131 (3). • Connect the object detector (5) to the IB-131 (3). • Connect the power supply (4) to the IB-131 (3). • Apply power to the reader.
RS-232 Hardware Configuration
MS-2 CCD Reader User’s Manual
1-3
Page 14
Install ESP
Step 3, Install ESP Easy Setup Program (ESP) is Microscan’s proprietary setup and testing application. The purpose of ESP is to provide a quick and easy way to set up and configure Microscan readers. When the MS-2 is connected to a host computer (Windows Vista, XP, or 2000), ESP can be used to configure reader settings and to set up communications between the reader and host.
If installing from the Microscan Tools CD: 1. Insert the Microscan Tools CD in your computer’s CD drive. 2. Select ESP Software from the navigation bar at the left of the screen. 3. Click on ESP Software under the Current Version heading. 4. Click the Run button and follow the prompts in the ESP Setup Wizard. Note: During installation, you may see an Internet Explorer Security Warning that states: “The publisher could not be verified.” If you see this warning, click Run to continue installation.
If downloading from the web: 1. Go to the Download Center at www.microscan.com. 2. Create a new member account or, if you are already a member, enter your user name and password. 3. Navigate to the “Microscan Software” section of the Download Center (near the top of the page). 4. Click on the link showing the latest version of ESP. Extract the ESP installation files to a location of your choice on the host computer. Note where your ESP.exe file is stored on your hard drive. 5. At the end of the installation process, the following icon will appear on your desktop:
6. Click the ESP icon to start the program.
System Requirements for ESP • 166 MHz Pentium processor (recommended) • Windows Vista, XP, or 2000 operating system • Internet Explorer 5.0 or higher • 64 MB minimum RAM • 40 MB minimum disk space • 800 x 600 pixel minimum 256 color display 1-4
MS-2 CCD Reader User’s Manual
Page 15
Quick Start
Step 4, Select Model When you start ESP, the following menu will appear:
1. Click the button showing the MS-2. 2. Click OK. Note: You can also double-click the MS-2 button to make your selection. 3. Click Yes when this dialog appears:
Note: If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar.
MS-2 CCD Reader User’s Manual
1-5
Page 16
Autoconnect
Step 5, Autoconnect • Click Start when the Autoconnect dialog appears.
• If your communications port is not the default COM1, use the dropdown menu to change your port.
• Once you have chosen the correct port, click Start to connect.
When you are connected, you will see the green connection indicator in the status bar at the bottom right of your screen:
• If the connection attempt fails, click the Autoconnect button, select a different communications port, and try again.
Note: If your RS-232 or USB host settings cannot be changed to match the reader’s settings, select Connect from the Connect dropdown menu on ESP’s menu toolbar. When the Connection Settings dialog appears, check the Force Connect box and click the Connect button.
1-6
MS-2 CCD Reader User’s Manual
Page 17
Quick Start
Step 6, Position the Reader • Set up a symbol at the distance you will be using in your application. Refer to the Read Ranges for your MS-2 model (High Density or Low Density) to determine the optimal distance. Note: If you are using an Interleaved 2 of 5 symbol, verify that the number or characters being scanned matches the symbol length enabled for I 2/5 (default is 10 and 6). • Avoid bright light or infrared light from other sources, including other readers. • Pitch the reader or symbol at a minimum of ±15° to avoid specular reflection (the return of direct, non-diffused light). • Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°.
Bar code label
Skew axis Tilt axis
Scanner Pitch axis
MS-2 Scan line
Reader and Symbol Orientation Note: Code 39 is the default symbology enabled. If you are uncertain of your symbology, perform the following steps: 1. Enable all symbologies using ESP. 2. Enable Symbology Identifier at the bottom of ESP’s Symbologies tree control.
3. Decode the symbol and compare the symbology identifier character to the list on page 5-20 to determine your symbology. 4. Disable all other symbologies.
MS-2 CCD Reader User’s Manual
1-7
Page 18
Configure the Reader
Step 7, Configure the Reader To make setup changes to the reader, click the App Mode button.
The following modes are accessible by clicking the buttons in the first row of App Mode icons:
• Click the Autoconnect button to establish communications between ESP and the reader. • Click the Send/Recv button to send or receive commands. • Click the Terminal button to display decoded symbol data, and to send serial commands to the reader using text or macros. • Click the Utilities button to test Read Rate, request or clear Counters, enable or disable the reader or send output pulses in Device Control, determine the Differences from Default in the current settings, add or remove master symbol data in Master Database, and verify or update the reader’s firmware. Click the Configuration button to display the second row of ESP icons.
From here you can make changes in the tree controls that can be accessed by clicking the buttons on the second row of icons in the ESP window.
For further details, see Microscan ESP Help in the dropdown Help menu.
1-8
MS-2 CCD Reader User’s Manual
Page 19
Quick Start
Step 8, Save Configuration in ESP To make changes to a configuration setting:
3. Place your cursor in the selection box, scroll down to the setting you want to change, and click once on the setting.
1. Left-click on the + to expand the desired tree. 2. Double-click on the desired parameter and click once in the selection box to view options.
4. Left-click again on the open screen to complete your selection.
5. Right-click on the open screen and select Save to Reader to implement the command in the reader.
Saving Options • Send, No Save. Changes will be lost when power is re-applied to the reader. • Send and Save. This activates all changes in current memory and saves to the reader for power-on.
MS-2 CCD Reader User’s Manual
1-9
Page 20
Save Configuration in ESP
1-10
MS-2 CCD Reader User’s Manual