Page 41

Basic Operations

Illumination System The Mobile Hawk incorporates the MAXlite (multi-axis lighting) illumination system, designed to ensure reliable decoding of the toughest direct part marks. Through an advanced combination of low angle (dark field) and multi-colored dome (bright field) illumination techniques, MAXlite provides even illumination of flat, shiny surfaces, enhancing embossed features, or differentiating features on curved surfaces.

Low Angle (Dark Field) Illumination The low angle illumination zone provides what is called “dark field” illumination, ideal for very low-contrast marks such as laser-embossed or engraved marks. This zone is useful on both specular and non-specular surfaces and emphasizes surface texture. The optimum lighting angle for most marks is 30 degrees, which occurs when the Mobile Hawk is approximately 0.25” away from the target mark. This illumination zone actually directs light inward at an angle, which varies with the actual working distance and provides a good source of low angle illumination from contact (5 degrees) to about 0.5 inch (45 degrees). Beyond this working distance for low angle illumination the illumination zone converts to a general purpose illuminator due to a portion of the illumination passing straight through the prism. This can be useful in providing “bright field” illumination. This zone was designed for reading larger marks such as 1D symbols at longer working distances.

Low Angle Illumination Zone 1 (Contact to 0.5”)

Low Angle Illumination Zone 2 (0.5” and greater)

Mobile Hawk Handheld DPM Imager User Manual

3-7

Page 42

Illumination System

Dome Illumination Dome illumination provides diffused, uniform light. The large, solid angle of illumination supports imaging of shiny flat surfaces or curved surfaces. This zone is useful on specular and non-specular surfaces, ideal for de-emphasizing surface texture and elevation (curves). The dome provides the widest area of coverage at close working distances. It is important to note that for marks that are a large percentage of the diameter of a curved surface, closer distances will provide the best performance. In addition to illuminating marks on curved surfaces, dome illumination also provides diffuse, even bright field illumination, which will provide thorough coverage on a wide variety of direct part marks.

Dome Illumination

Blue Dome vs. Red Dome Illumination The Mobile Hawk features two colors of dome illumination to add another dimension of decode optimization for direct part marks. Using the opposite light spectrum as a part’s surface color will make the part feature appear darker. Using the same light spectrum will make the part feature appear lighter. The example below shows a green part surface with a laser-etched Data Matrix.

Blue Dome Illumination

3-8

Red Dome Illumination

Mobile Hawk Handheld DPM Imager User Manual

Page 43

Basic Operations

Illumination Sequence The Mobile Hawk is configured to provide the broadest reading capabilities “out of the box”. Just point and shoot to read most marks. This is achieved by combining the MAXlite illumination system with Microscan’s advanced X-Mode algorithms. The Mobile Hawk automatically cycles through a default combination of the MAXlite illumination zones each time the user pulls the trigger to decode a mark. The imager will then lock onto the settings used in the last good read and move those to the first step in the next sequence. The Mobile Hawk has four steps defined in this default illumination sequence: 1. Low Angle Illumination with Low Resolution Image Low Angle Illumination

2. Low Angle Illumination with Full Resolution Image

Low Angle Illumination

3. Blue Dome Illumination

Blue Dome Illumination

4. Red Dome Illumination Red Dome Illumination

With ESP Software, the user can change this sequence or define a different sequence. It is possible to have one step to as many as eight steps defined. ESP allows the user to evaluate the best settings. Note: Decode speed can be improved with fewer illumination steps. Note: Hovering over an uploaded image in ESP with your cursor will display the settings used to capture the image. In addition to the general purpose sequence, a special sequence has been defined for dot peen marks. This adds additional X-Mode pre-processing to the sequence steps, allowing you to read some of the most challenging direct part marks with ease. Mobile Hawk Handheld DPM Imager User Manual

3-9

Page 44

Illumination Sequence

3-10

Mobile Hawk Handheld DPM Imager User Manual

Page 45

4 Communications Contents Communications by ESP.............................................................................................................. 4-2 Communications Overview........................................................................................................... 4-3 USB Interface ............................................................................................................................... 4-4 RS-232 Interface .......................................................................................................................... 4-5 Preamble ...................................................................................................................................... 4-7 Postamble..................................................................................................................................... 4-9 Preamble and Postamble by ESP .............................................................................................. 4-11 Keyboard Mapping .................................................................................................................... 4-12 Text Commands ......................................................................................................................... 4-13 Other Communications Settings in ESP..................................................................................... 4-14

This section includes connection parameters and options for communicating with the Mobile Hawk Handheld DPM Imager in various interfaces.

Mobile Hawk Handheld DPM Imager User Manual

4-1

Page 46

Communications by ESP

Communications by ESP To make changes to configuration settings in the Communications tree control:

1. Left click on the + to expand the tree.

2. Double click on the parameter and click once in the selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change and click once on the setting.

4-2

4. Left click again on the open screen to complete the selection. 5. Right click on the open screen and select Save to Reader to implement the command in the imager.

Mobile Hawk Handheld DPM Imager User Manual

Page 47

Communications

Communications Overview All Mobile Hawk Handheld DPM Imagers are shipped with a USB cable. You can also add RS-232 capabilities and configure your imager accordingly. Whenever you default the imager, it will return to the default settings of whichever interface you are using. Defaulting the imager does not remove preamble and postamble formatting. Note: You must use USB Connect Mode or RS-232 Connect Mode to connect to ESP. Once the imager is connected to ESP, you can select your communications mode and set other communication parameters.

USB With USB communications, the imager connects directly to the host’s USB port from which it draws its power. Data is displayed by any open Windows-based program that can capture text in USB Keyboard Mode.

RS-232 With RS-232 communications the imager communicates with the host through a communications program such as HyperTerminal. Default settings for establishing RS-232 communications are: Baud = Stop Bits = Data Bits = Parity =

57.6K 2 8 None

Mobile Hawk Handheld DPM Imager User Manual

4-3

Page 48

USB Interface

USB Interface USB Keyboard is the default interface in which data is transferred to a Windows-based text program as keyboard data. See USB Interface for detailed steps on setting up the USB Interface.

USB Keyboard Mode Data is entered as keyboard sequences. You need to read this symbol whenever you are changing from a different interface to USB.

USB Downloader Mode This mode is the standard way of transferring unformatted, unpacketized data to the imager through the USB port.

USB Native Two-Way Mode This mode is used when the user needs error-corrected communication between the Mobile Hawk and the USB port.

USB Virtual COM Mode This mode allows an Mobile Hawk in a USB configuration to function as a virtual serial COM port. This mode requires installation of a USB Virtual COM driver. The USB Virtual COM Port Driver can be found in the Download Center on the Microscan website.

Save Settings 4-4

Mobile Hawk Handheld DPM Imager User Manual

Page 49

Communications

RS-232 Interface Enabling either of these modes will disable USB communications and require you to default the imager or read the “USB Keyboard” symbol to return to USB. See RS-232 Interface for detailed steps on setting up the RS-232 Interface.

RS-232 Default Settings This mode is the standard way of transferring unformatted, unpacketized data through the RS-232 port.

You will need to read this symbol whenever you set up RS-232 communications.

Baud Rate (RS-232) Baud Rate is the rate at which the imager and host transfer data. It only needs to be changed if necessary to match the host setting.

1200

19.2K

2400

38.4K

4800

57.6K (Default)

9600

115.2K

Save Settings Mobile Hawk Handheld DPM Imager User Manual

4-5

Page 50

RS-232 Interface

Parity (RS-232) Parity is an error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd. It only needs to be changed if necessary to match the host setting.

None (Default)

Odd

Even

Stop Bits (RS-232) Stop Bits are added to indicate the end of each character. This setting should only be changed if necessary to match the host setting. 2 Stop Bits (Default)

1 Stop Bit

Data Bits (RS-232) Data Bits are the total number of bits in each character. This setting only needs to be changed if necessary to match the host setting.

8 Data Bits (Default)

7 Data Bits

Save Settings

4-6

Mobile Hawk Handheld DPM Imager User Manual