The text of a manual · part 2 of 13
Mobile Hawk Handheld DPM Imager User Manual, pages 11 to 20
Pages 11 to 20 of 128
The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan Mobile Hawk 6170
Page 11
Quick Start
USB Interface Note: The USB interface draws its power from the host.
USB Configuration Item 1 2
Description Mobile Hawk Handheld DPM Imager USB Cable
Part Number FIS-6170-0002G Included
Installation Steps for USB 1. Connect the USB cable to the host. 2. Open any program in your host computer that can receive keyboard text, such as Notepad. 3. Read the Reset to USB Factory Defaults symbol below:
Reset to USB Factory Defaults 4. Read the Save Settings symbol.
USB Configuration
Save Settings Test Symbol
(ABCDEFGHIJKLMNOP)
Mobile Hawk Handheld DPM Imager User Manual
1-3
Page 12
RS-232 Interface
RS-232 Interface Note: Unlike USB, the RS-232 interface does not draw its power from the host computer.
RS-232 Configuration Item 1 3
Description Mobile Hawk Handheld DPM Imager RS-232 Interface Kit (USA) RS-232 Interface Kit (Europe) RS-232 Interface Kit (UK)
Part Number FIS-6170-0002G 98-000074-04 98-000074-05 98-000074-06
Installation Steps for RS-232 1. Power-off the host. 2. Connect the 8-pin mini-DIN on the cable to the Mobile Hawk. 3. Connect the 9-pin D-sub connector to the host computer’s serial port. 4. Connect the cable to the power supply. 5. Plug in the power supply and power-on the host. 6. Start up a terminal program (such as ESP’s Terminal view or HyperTerminal) and set to 57.6K baud, 8 data bits, none parity, and 2 stop bits. 7. Read the Reset to RS-232 Factory Defaults symbol below.
RS-232 Configuration
Reset to RS-232 Factory Defaults 8. Read the Save Settings symbol. Save Settings Test Symbol
(ABCDEFGHIJKLMNOP)
1-4
Mobile Hawk Handheld DPM Imager User Manual
Page 13
Quick Start
Install ESP ESP Software can be found on the Microscan Tools Drive that is packaged with the Mobile Hawk. 1. Follow the prompts to install ESP from the Tools Drive. 2. Click on the ESP icon to run the program.
Note: ESP can also be installed from the Download Center at www.microscan.com.
ESP System Requirements
• 233 MHz Pentium PC • Windows 8, 7, Vista, or XP operating system (32-bit or 64-bit) • Internet Explorer 6.0 or higher • 128 MB RAM or greater • 160 MB free disk space • 800 x 600 256 color display (1024 x 768 32-bit color recommended) Important: The imager must be in one of the modes below to communicate with ESP. Read the symbol below that corresponds with your communication interface, and then read the Save Settings symbol.
USB
USB Connect Mode
RS-232
RS-232 Connect Mode
Save Settings
Mobile Hawk Handheld DPM Imager User Manual
1-5
Page 14
Select Model
Select Model When you start ESP, the following menu will appear:
If you need to select another model later, click Switch Model at the top of the screen.
1. Click the Mobile Hawk button and then click OK. If you do not want to make this selection every time you start ESP, uncheck “Show this dialog at startup”. 2. Select the default reader name (Mobile Hawk-1), or type a name of your choice in the Description text field and click OK. 3. Click Yes when this dialog appears:
1-6
Mobile Hawk Handheld DPM Imager User Manual
Page 15
Quick Start
Select Interface and Connect to Imager USB (Standard) • In the Select Protocol dialog box, select the communications protocol you are using and click Next.
From the default USB settings, click the Switch Mode button to connect to the reader in USB HID Mode.
• Print the USB Connect Mode symbol (also shown in the Install ESP step) and decode it with the imager to ensure that you are in the correct communications mode. Keep the printed symbol in a convenient place for future use. • Click Next when you are finished. The USB Select Device dialog will then reappear:
Reader ID number should match the serial number on the base of the imager.
• You will see a “Reader ID” number in the USB Select Device field. Click Connect. • When you are connected successfully, the CONNECTED message will appear in a green box in the status bar at the bottom right of the screen.
You are now ready to configure your imager using ESP. Subsequent sections provide more detailed information about ESP’s configuration options.
Mobile Hawk Handheld DPM Imager User Manual
1-7
Page 16
Select Protocol and Connect to Imager
RS-232 Option • Select RS-232 and click the Show Connect Symbol button.
• Print the RS-232 Connect Mode symbol (also shown in the Install ESP step) and decode it to ensure that you are in the correct communications mode. Keep the printed symbol in a convenient place for future use. • Click Next to return to the RS-232 dialog. • Configure RS-232 settings and COM port and click Connect.
• When you are connected successfully, the CONNECTED message will appear in a green box in the status bar at the bottom right of the screen.
If the connection attempt fails, enable a different communications port, check your port connections, and try again. You are now ready to configure your imager using ESP. Subsequent sections provide more detailed information about ESP’s configuration options.
1-8
Mobile Hawk Handheld DPM Imager User Manual
Page 17
2 Using ESP EZ Mode ....................................................................................................................................... 2-2 Application Mode .......................................................................................................................... 2-4 Tree Controls................................................................................................................................ 2-5 Menu Toolbar ............................................................................................................................... 2-6 Send/Receive ............................................................................................................................ 2-16
This section is designed to help you understand the structure and application of ESP. When you open ESP, unless otherwise specified in the ESP Preferences dialog accessible from the Options heading on the menu toolbar, you will enter EZ Mode for initial setup. From there, you can enter Application Mode (App Mode) and access several configuration menus (Communications, Read Cycle, Symbologies, I/O Parameters, a Terminal interface, and a Utilities interface). ESP can be used to configure the Mobile Hawk Handheld Imager in the following ways: • Tree Controls: Each configuration menu contains a list of all option settings that pertain to that specific element of imager operation. For example, the Communications menu shows a Communications Mode command, and then the options RS-232 Serial, USB Keyboard, and USB Native (HID), all of which are accessible from a dropdown menu. • Graphic User Interfaces: Settings can be configured using such point-and-click tools as radio buttons, tabs, spin boxes, check boxes, and drag-and-drop functions. • Terminal: ESP’s Terminal interface allows you to send configuration and utility commands directly to the imager by typing them in the provided text field.
Mobile Hawk Handheld DPM Imager User Manual
2-1
Page 18
EZ Mode
EZ Mode The EZ Mode screen is the first thing you will see when you start ESP. EZ Mode will help you get your imager up and running quickly, and will acquaint you with the ESP interface. The purpose of Dot Peen Enhanced in Illumination Quick Setup is to optimize settings for typical dot peen marks. Dot Peen Enhanced causes the imager to run a two step illumination sequence (Low Angle and then Red Dome) and matches the morphological operator (Grow Dark and Grow Light) to the expected dot peen response. The size of the morphological operator is selectable (Small, Medium, or Large). These settings can also be controlled by programming symbols (see Dot Peen Enhanced Illumination Settings).
Click Start to upload the most recent image acquired before releasing the trigger. When an image is captured, it is displayed here. Click Save Image to save it to a location of your choice. Good read images show a green border around the symbol. If you hover your cursor over the symbol, you will see the illumination, gain, and resolution settings that were used in capturing the image. Symbol data is displayed in the area under the Save Image button.
2-2
Mobile Hawk Handheld DPM Imager User Manual
Page 19
Using ESP
Image Quality The video view in EZ Mode (and also on the Video tab in I/O Parameters) allows you to capture images from the Mobile Hawk for further analysis. If Upload Images is checked and you click the Start button, image captures will be uploaded automatically for every good read. Images will also be uploaded for every no read, upon release of the imager’s trigger. You can right-click on a captured image to bring up the menu shown below. If you select Store higher quality images, you will see a dropdown menu with JPEG 60% quality (small size), JPEG 80% quality (full size), JPEG 100% quality (full size) and TIFF (full size). The imager’s illumination setup can be restored by clicking the Default box in the EZ Mode view. Refer to the Basic Operations section for more information about the Mobile Hawk’s illumination capabilities. Note: If you have difficulty viewing TIFF images with Windows Photo Viewer, it is recommended that you use Paint or viewer software that is optimized for TIFF files. Note: TIFF images are large files and take significantly longer to download than JPEG images. Right-click on the image capture to bring up this menu.
Note: Image size will vary depending on user settings for Region of Interest, and whether or not Low Resolution Image is checked in the Illumination dialog in ESP. Image Save Mode Small Size (Displayed) Small Size Small Size Small Size Full Size Full Size Full Size Full Size
Region of Interest 1280 x 1024 1280 x 1024 800 x 600 800 x 600 1280 x 1024 1280 x 1024 800 x 600 800 x 600
Mobile Hawk Handheld DPM Imager User Manual
Low Resolution No Yes No Yes No Yes No Yes
Final Image Size 320 x 256 320 x 256 400 x 296 400 x 296 1280 x 1024 640 x 512 800 x 600 400 x 296 (JPEG); 400 x 300 (TIFF)
2-3
Page 20
Application Mode
Application Mode Application Mode gives you access to a robust configuration environment, including tree controls that let you make precise changes to operation parameters, and graphic interfaces that make configuring your imager easy and intuitive. Click here to return to EZ Mode.
Click on this icon to return to this view from Utilities or Terminal.
Menu toolbar
Click these buttons to Send and Receive commands or switch reader models.
Click here to open Terminal.
Click here for Batch Files and Firmware.
Click these tabs to access configuration tree controls.
Assign Preamble and Postamble characters using the simple interface shown above.
Note: For specific information on any of the icons shown above in the operations bar or configuration bar, see corresponding sections.
2-4
Mobile Hawk Handheld DPM Imager User Manual