Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 12 of 13

Mobile Hawk Handheld DPM Imager User Manual, pages 111 to 120

Pages 111 to 120 of 128

The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan Mobile Hawk 6170

Page 111

Terminal

Terminal Dropdown Menu The terminal dropdown menu allows you to capture and save current text, and it also includes the functions defined for the Terminal Right-Click Menu. • Capture Text... lets you append data in real time to a text file of your choice. While in operation, the text file cannot be opened. You can select Pause to interrupt the capture flow or Stop to end the flow and open the file. • Save Current Text... saves all text in the terminal window to a text file of your choice. • Find Next locates the next instance of the specified data string in the terminal. This function can also be activated by pressing F3. • Find Previous locates the most recently occurring instance of the specified data string in the terminal. • Keyboard Macros brings up the Function Keys dialog, which allows you to create customized macro functions.

Mobile Hawk Handheld DPM Imager User Manual

9-7

Page 112

Terminal Dropdown Menu

9-8

Mobile Hawk Handheld DPM Imager User Manual

Page 113

10 Utilities Contents Device Control.............................................................................................................................10-2 Differences from Default .............................................................................................................10-3 Firmware .....................................................................................................................................10-4 Advanced ....................................................................................................................................10-6

This section explains ESP’s Utilities features. These include Device Control, an interface that lets you perform major operations with one click; Differences from Default, which shows all currently enabled Mobile Hawk settings that are not default settings; Firmware, where you can update your imager’s firmware; and Advanced, which allows you to collect batch files for customized imager configuration and optimization.

Mobile Hawk Handheld DPM Imager User Manual

10-1

Page 114

Device Control

Device Control This feature allows you to clear data stored in the imager’s memory, to default the imager, to deactivate or clear XML rules, to upload or delete stored errors, to reboot the imager, and to delete stored results.

• Clear All Data removes decoded symbol data and commands in the imager’s memory. • Default Reader returns the imager to its default state, without any optimization or configuration. • Deactivate XML Rules turns off, but does not erase, preambles, postambles, and XML commands. • Clear XML Rules removes preambles, postambles, and other XML commands. • Reboot Reader refreshes the imager’s memory and functionality, returning it to the most recent configuration you have saved. • Delete Stored Results erases logged data.

10-2

Mobile Hawk Handheld DPM Imager User Manual

Page 115

Utilities

Differences from Default Clicking the Differences from Default button will cause ESP to check all stored configuration settings and compare them to default settings. All settings that are different from default will appear in the left column (shown below), and descriptions of those settings will appear in the right column. Click this button for a list of ESP configuration settings that are different from default settings.

Click Generate Bar Code to bring up the Bar Code Configuration dialog. Then create symbols containing the configuration commands of your choice.

Send configuration settings to the imager without saving by clicking Send to Reader.

Click Save As to save the report as plain text or a tab-delimited text file.

Send configuration settings to the imager and save in ESP by clicking Send and Save.

• To create a symbol containing any of the command settings in the table, click Generate Barcode. This will bring up the Bar Code Configuration dialog. • To save the Differences from Default report, either as plain text or as a tab-delimited text file, click Save As. • Click Send and Save to send the settings to the imager and save them, or Send to Reader to send the settings without saving them.

Mobile Hawk Handheld DPM Imager User Manual

10-3

Page 116

Firmware

Firmware The Firmware view in ESP Utilities is a simple way to update and verify your imager’s firmware and to update batch files. Choose App Code from the Firmware Update dropdown menu and click Start to install new firmware in the Mobile Hawk.

Use this dropdown menu to locate batch files in the host computer’s file directory. Download the needed files directly to the imager by clicking the Start button.

The Firmware Verification tool sends a direct query to the imager for its Application Code Version, Firmware Version, Boot Code Version, and Radio Version.

Note: To ensure correct operation, cycle power to the imager (turn the imager off and then on) after the firmware update is complete.

10-4

Mobile Hawk Handheld DPM Imager User Manual

Page 117

Utilities

Imager ID Another way to query the imager for its identifying information is by reading the following symbol:

Imager ID

Save Settings

The host’s text program will output a data string containing the imager’s identifying information in the following format: Serial number

Hardware version

Build number

@.U|.J.X.ap/i42440138none00100911810200016040002422700170001.35-617001-10 006

Boot code version

Mobile Hawk Handheld DPM Imager User Manual

Hardware type

Firmware version

10-5

Page 118

Advanced

Advanced The Advanced tab in Utilities features an archive of all batch files containing imager configuration commands. Each batch file’s extension is .crb, and each file contains the fundamental code for programming the imager. Notice that the names of the batch files correspond with the numbers beneath all the Data Matrix configuration symbols. This tool allows you to use the batch file data to create your own symbols, or to collect only the files that you use frequently to configure the imager for your application.

The Download Collection and Save Collection As... buttons allow you to acquire the entire contents of the batch file archive and save the files in a location of your choice.

Scroll through the list of batch files in the archive and choose the ones you need. Move them to the collection window using the Add arrow. Files can also be transferred by clicking and dragging. The single Remove arrow functions in the same way as the Add arrow, except that it transfers files back to the batch archive. The double Remove arrow allows you to transfer all files simultaneously.

10-6

Mobile Hawk Handheld DPM Imager User Manual

Page 119

Appendices Appendix A General Specifications ..............................................................................................A-2 Appendix B Electrical Specifications ............................................................................................ A-4 Appendix C Default/Reset Procedure........................................................................................... A-7 Appendix D Maintenance ............................................................................................................. A-8 Appendix E Troubleshooting ........................................................................................................ A-9

Mobile Hawk Handheld DPM Imager User Manual

A-1

Page 120

General Specifications

Appendix A, General Specifications Mechanical Height: 7” (180 mm) Width: 2.5” (63 mm) Depth: 4.5” (114 mm) Weight: 7.2 oz. (204 g) (not including cable)

Note: Nominal dimensions shown. Typical tolerances apply.

Detail A

Environmental

Operating temperature: 0° to 50°C (32° to 122°F) Storage temperature: –20° to 65° C (–4° to 150°F) Humidity: 5 to 95% (non-condensing) Shock: Withstands >50 drops of 6’ (1.8 meters) to concrete

MAXlite Illumination

Combination Dome and Low Angle illumination system. Dome: 2-color, 640nm (red) and 470nm (blue) Low Angle: Quadrant 30°, 640nm (red)

Symbologies

Aztec, BC412, Codabar, Code 39, Code 93, Code 128, Data Matrix (ECC 0-200), GS1 DataBar, Interleaved 2 of 5, MicroPDF417, Micro QR Code, PDF417, Pharmacode QR Code, UPC/EAN

Front View

Image Collection Options Sensor: CMOS Sensor Array: 1280 x 1024

Communication Protocols Standard Interface: USB, RS-232

Read Parameters

Rotational Tolerance: ±180° Focal Range: 0 to 2” (0 to 50.8 mm) Focal Point: Optimal at 0.25” (6.3 mm) Field of View: Horiz. 1.59” (40.39 mm) x Vert. 1.27” (32.31 mm) at optimum focus Print Contrast Resolution: 20% minimum contrast Ambient Light Immunity: Sunlight: Up to 9,000 ft. candles, 96,890 lux

Use #2-56 hardware; do not exceed .115” depth. Note: For training accessories only; not for mounting purposes.

Detail A

Indicators

Status Indicators: Vibration motor, audible tones, visual feedback with multi-color LED, blue-line targeting pattern

Image Output Options Format: JPEG, TIFF

Electrical

Power Requirements: 5 VDC (mA) Typical: 408mA Peak: 500mA Idle: 285mA

Side View Mobile Hawk Dimensions

A-2