Page 261
11 Configuration Database Contents Configuration Database Serial Commands ................................................................................ 11-2 Number of Active Indexes .......................................................................................................... 11-3 Configuration Database Status................................................................................................... 11-4 Database Mode ........................................................................................................................ 11-10 Save Current Settings to Configuration Database.................................................................... 11-15 Load Current Settings from Configuration Database................................................................ 11-16 Request Selected Index Settings ............................................................................................. 11-17 Request All Configuration Database Settings .......................................................................... 11-18
This section concerns the various capture settings and processing settings that can be used to fine-tune the MINI Hawk Xi’s performance in your application.
MINI Hawk Xi High Performance Imager User Manual
11-1
Page 262
Configuration Database Serial Commands
Configuration Database Serial Commands Number of Active Indexes Configuration Database Status Save Current Settings to Database Load Current Settings from Database Request Selected Index Settings Request All Database Settings Database Mode
11-2
<K252,number of active database settings,database sort> <K255,index,shutter speed,gain,focal distance, pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> <K255+,index> <K255-,index> <K255?,index> <K255?> <K256,switch mode,frame count/time,image process looping,image dimensions>
MINI Hawk Xi High Performance Imager User Manual
Page 263
Configuration Database
Number of Active Indexes Usage:
Definition:
Serial Cmd: Default: Options:
Useful for applications that require several different complex imager configurations to be applied sequentially. Multiple database indexes allow you to concatenate configuration profiles, and to perform more complex operations than would be possible with only one set of configuration parameters. This feature allows you to set the number of database records (groups of settings) that will be used automatically during the read cycle. If Number of Active Indexes is set to 0, only the current imager settings will be used, not database entry settings. <K252,number of active indexes,database sort> 0 (disabled) 0 to 10
Database Sort Definition: Serial Cmd: Default: Options:
Database Sort moves the database entry that produced a successful decode to the first position in the list of database entries. <K252,number of active indexes,database sort> Disabled 0 = Disabled 1 = Enabled
Number of Active Indexes by ESP Click the arrow on the Active Indexes dropdown menu and select how many database indexes will be used during the read cycle. (0 to 10).
Sort Index Positions on Good Reads moves the database entry that produces the first successful decode to the top of the list.
MINI Hawk Xi High Performance Imager User Manual
11-3
Page 264
Configuration Database Status
Configuration Database Status Index Usage:
Useful for applications that require several different complex imager configurations to be applied sequentially. Multiple database indexes allow you to concatenate configuration profiles, and to perform more complex operations than would be possible with only one set of configuration parameters. Definition: Determines the specific database index that will be used. Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> Options: 1 to 10
Shutter Speed Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> Default: 250 Options: 15 to 12,500
Gain Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> Default: 20 Options: 0 to 33
Focal Distance Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> Default: 400 (4”) Options: 200 to 600
11-4
MINI Hawk Xi High Performance Imager User Manual
Page 265
Configuration Database
Pixel Sub-Sampling Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> Default: Disabled Options: 0 = Disabled 1 = 4:1 2 = 16:1 Important: Pixel Sub-Sampling has no effect when the Image Dimension mode is configured as Region of Interest in the Database Mode command. This is because the Window of Interest camera settings are determined by the software based on the Region of Interest setup. There is no benefit to Pixel Sub-Sampling to increase processing speed when ROI is configured, because the frame size would need to be increased to make Pixel Sub-Sampling possible.
Row Pointer Definition:
The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> Default: 0 Options: High Resolution MINI Hawk Xi: 0 to (1024 – row depth) High Speed MINI Hawk Xi: 0 to (480 – row depth)
Column Pointer Definition:
The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> Default 0 Options: High Resolution MINI Hawk Xi: 0 to (1280 – column width) High Speed MINI Hawk Xi: 0 to (752 – column width)
MINI Hawk Xi High Performance Imager User Manual
11-5
Page 266
Configuration Database Status
Row Depth Definition:
The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer, column pointer,row depth,column width,narrow margins,background color, symbology> Default: High Resolution MINI Hawk Xi: 1024 High Speed MINI Hawk Xi: 480 Options: High Resolution MINI Hawk Xi: 3 to (1024 – row pointer) High Speed MINI Hawk Xi: 3 to (480 – row pointer)
Column Width Definition:
The image dimension settings can be applied as a Window of Interest or a Region of Interest, depending on the image dimension mode selected in the Database Mode command. Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> Default High Resolution MINI Hawk Xi: 1280 High Speed MINI Hawk Xi: 752 Options: High Resolution MINI Hawk Xi: 8 to (1280 – column pointer) High Speed MINI Hawk Xi: 8 to (752 – column pointer)
Narrow Margins Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> Default: Disabled Options: 0 = Disabled 1 = Enabled
11-6
MINI Hawk Xi High Performance Imager User Manual
Page 267
Configuration Database
Background Color Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> Default: Both Options: 0 = White 1 = Black 2 = Both
Symbology Definition:
This field allows the user to configure the database to enable specific symbologies for selected database indexes. Symbology-specific parameters must be configured with the appropriate symbology command. For example, if fixed length Code 128 is required, it must first be set up with the Code 128 command: <K474>. To select a particular symbology, add the number value associated with that symbology. Examples: If Data Matrix and Code 39 are required, the paramater would be: 2 + 16 = 18.
If I 2/5, BC412, and DataBar Limited (RSS Limited) are required, the parameter would be: 128 + 2048 + 16384 = 18560. Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row pointer,column pointer,row depth,column width,narrow margins,background color,symbology> Default: Disabled
Disabled When Symbology is disabled, the database uses the current Symbology setup to determine active symbologies.
Any Symbology (Add 1) All symbologies except Pharmacode are enabled while this database index is being used.
Data Matrix (Add 2) If enabled, Data Matrix will be active for this database index. Important: The ECC level must be configured using the Data Matrix command <K479>. If no ECC level has been configured, the imager will not decode Data Matrix symbols.
QR Code (Add 4) If enabled, QR Code will be active for this database index.
Code 128 (Add 8) If enabled, Code 128 will be active for this database index. MINI Hawk Xi High Performance Imager User Manual
11-7
Page 268
Configuration Database Status
Code 39 (Add 16) If enabled, Code 39 will be active for this database index.
Codabar (Add 32) If enabled, Codabar will be active for this database index.
Code 93 (Add 64) If enabled, Code 93 will be active for this database index.
Interleaved 2 of 5 (Add 128) If enabled, Interleaved 2 of 5 will be active for this database index.
UPC/EAN (Add 256) If enabled, UPC/EAN will be active for this database index.
PDF417 (Add 512) If enabled, PDF417 will be active for this database index.
MicroPDF417 (Add 1024) If enabled, MicroPDF417 will be active for this database index.
BC412 (Add 2048) If enabled, BC412 will be active for this database index.
Pharmacode (Add 4096) If enabled, Pharmacode will be active for this database index.
DataBar-14 (RSS-14) (Add 8192) If enabled, DataBar-14 will be active for this database index. Important: If the stacked and non-stacked operation is required, the DataBar-14 command must be configured as follows: <K482,2>. If the DataBar-14 status parameter in the <K482> command is set to either DISABLED or ENABLED, the imager will only read non-stacked DataBar-14 symbols.
DataBar Limited (RSS Limited) (Add 16384) If enabled, DataBar Limited will be active for this database index.
DataBar Expanded (RSS Expanded) (Add 32768) If enabled, DataBar Expanded will be active for this database index. Important: If the stacked and non-stacked operation is required, the DataBar Expanded command must be configured as follows: <K484,2>. If the DataBar Expanded status parameter in the <K484> command is set to either DISABLED or ENABLED, the imager will only read non-stacked DataBar Expanded symbols.
11-8
MINI Hawk Xi High Performance Imager User Manual
Page 269
Configuration Database
Micro QR Code (Add 65536) If enabled, Micro QR Code will be active for this database index.
Aztec Code (Add 131072) If enabled, Aztec Code will be active for this database index.
Postal Symbologies (Add 262144) If enabled, Postal Symbologies will be active for this database index.
MINI Hawk Xi High Performance Imager User Manual
11-9
Page 270
Database Mode
Database Mode Switch Mode Definition:
Selects the event that causes the imager to load the next database entry to current, active settings. When Frame Count/Time expires and Image Process Looping is enabled, the next database entry with modifications to camera settings will be used. Note: The image capture event always occurs when the first database entry is used. Note: The Switch Mode setting has no effect on Rapid Capture Mode, which always operates in Number of Image Frames mode with a frame count of 1. Serial Cmd: <K256,switch mode,frame count/time,image process looping,image dimensions> Default: 1 Options: 0 = Time 1 = Number of Image Frames
Time When Switch Mode is set to Time, the imager will load the next database entry to current, active settings after a predefined time interval. The timer will start upon use of a database entry. If the timer expires during an image capture event, the timer will not start again until that database entry has been incremented and the new database entry has been loaded to current, active settings.
Number of Image Frames When Switch Mode is set to Number of Image Frames, the database entry is incremented after the predetermined number of image capture events has occurred.
Frame Count/Time Definition:
Indicates the Number of Image Frames that must be captured or the amount of Time that must transpire before the imager will load the next database index entry. Serial Cmd: <K256,switch mode,frame count/time,image process looping,image dimensions> Default: 1 (frames/ms) Options: 1 to 65535
11-10
MINI Hawk Xi High Performance Imager User Manual