The text of a manual · part 26 of 39
MINI Hawk Xi High Performance Imager User Manual, pages 251 to 260
Pages 251 to 260 of 388
The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan Mini Hawk Xi
Page 251
Camera and IP Setup
Increment Focus Position Definition:
Serial Cmd: Options:
Increments the imager’s focus setting to the next focal distance supported by the imager. Note: Use the Focus Distance Table command <K526> to find the focal distance settings supported by your imager. <K525+> 200 (2”) to 600 (6”)
The following example assumes a focus position setting of 400 (4”), with access to the focus distance values shown in the imager response. Send: <K526?> Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533, 539,545,550,556,561,565,570,574,578,582,586,590,594,597,601> The current focus position would be 410 (4.1”). Send: <K525+> Send: <K525?> Response: <K525,447>
Decrement Focus Position Definition:
Serial Cmd: Options:
Decrements the imager’s focus setting to the next focal distance supported by the imager. Note: Use the Focus Distance Table command <K526> to find the focal distance settings supported by your imager. <K525-> 200 (2”) to 600 (6”)
The following example assumes a focus position setting of 400 (4”), with access to the focus distance values shown in the imager response. Send: <K526?> Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533, 539,545,550,556,561,565,570,574,578,582,586,590,594,597,601> The current focus position would be 410 (4.1”). Send: <K525-> Send: <K525?> Response: <K525,264>
MINI Hawk Xi High Performance Imager User Manual
10-21
Page 252
Illumination Brightness
Illumination Brightness Definition:
Serial Cmd: Default: Options:
This feature allows the user to adjust the brightness of the illumination LEDs. Since the imager has control over the brightness of the illumination, it can provide consistent brightness output between imagers through a factory calibration operation. Each of the brightness settings is calibrated to provide the same level of intensity for each imager. <K536,brightness> High 0 = Off 1 = Low 2 = Medium 3 = High 4 = Constant
Constant When set to Constant, the illumination is the same as the Medium setting. However, the LEDs will always be on during a read cycle and will only be off between read cycles. This cuts down on perceptible LED flashing.
10-22
MINI Hawk Xi High Performance Imager User Manual
Page 253
Camera and IP Setup
Skew Correction Note: Skew Correction does not apply to the High Speed version of the MINI Hawk Xi, which has a global shutter. The MINI Hawk Xi’s CMOS image sensor has a “rolling shutter” mechanism that controls pixel integration row-by-row, unlike a global Full Image Height shutter, which performs light integration of all pixels at once. When a row of pixels has integrated light for the amount of time specified Full Image Width by the user-defined shutter speed, that row will be read out. The rows of the image are exposed individually in rapid sequence. As a symbol moves through the field of view, it is in a different position at each row read-out. This creates distortion, or “skew”, as in the image shown below. In this image, the symbol is moving from left to right at a line speed of 40 inches per second. The bottom of the symbol is read out first while the upper portion is still being integrated, causing distortion along the symbol’s x-axis. Note: The amount of blur in the image is an effect of shutter speed, and is not a factor in rolling shutter distortion. If the symbol enters the imager’s field of view from the top or bottom, distortion will occur on the y-axis. The image below shows two symbols entering the field of view from the top at different line speeds. As you can see, this causes the image to shrink along the y-axis. This is because the symbol is moving perpendicular to the CMOS sensor’s row read-out. In other words, the bottom of the symbol is read out first, and as the symbol moves information is lost (the symbol enters pixel rows that have already been processed). This causes the symbol to appear to shrink vertically. Note: If the symbol were to enter the field of view from the bottom, the captured image would be stretched along the y-axis. 10” / sec
16” / sec
Direction of symbol movement
Full Image Width
The amount of rolling shutter distortion depends upon the amount of time it takes to read out an image row, and the line speed at which the target object is traveling. Therefore, one way to reduce skew is to speed up the read-out time per pixel row. This can be accomplished by reducing the column size of the image sensor. For example, if the column size is reduced from 640 to 320, the time it takes to read out a row of pixels from the sensor is reduced by half, and image skew will be reduced by a factor of 2. As the column dimension of the image is reduced, the effect of rolling shutter distortion is reduced by the same factor. Important: Reducing the row size of the image has no effect, because it does not change the row read-out time. Skew will remain the same regardless of row size. 10-23 MINI Hawk Xi High Performance Imager User Manual
Page 254
Skew Correction
Line Speed Definition:
Serial Cmd: Default: Options:
This feature is used to specify the line speed of the application, and it determines how much distortion correction to apply. When enabled, this feature will cause the overall decode rate to increase significantly. The timing information in the table below is for a full megapixel image (1280 x 1024). Note: Processing time decreases with larger image sizes. <K537,line speed,symbol direction> 0 (Disabled) 0 to 80 (inches per second)
Line Speed 10” / sec 20” / sec 30” / sec 40” / sec 60” / sec 80” / sec
Additional Processing Time 69.5 ms 65.0 ms 62.5 ms 58.0 ms 55.0 ms 45.5 ms
Distortion is corrected by shifting image rows in the direction opposite the symbol’s movement on the line. The shift value of subsequent image rows is then increased. These shift values depend on the speed of the line. The faster the line speed, the greater the required shift values. More data loss is incurred at faster line speeds. The image shown below was captured at a line speed of 40 inches per second, and it shows virtually no inherent skew. The black area of the image is unusable, since the information was lost as the symbol moved through the imager’s field of view.
The amount of data loss can be reduced by decreasing the image height or the row size of the image, which reduces the amount of travel represented during the image frame read-out. Note that the amount of distortion will not be changed, because the object will have traveled the same distance during the read-out of the target area.
10-24
MINI Hawk Xi High Performance Imager User Manual
Page 255
Camera and IP Setup
Symbol Direction Definition:
Serial Cmd: Default: Options:
This feature specifies the direction the symbol is moving through the imager’s field of view, or which side of the field of view the symbol will enter first. Note: Image captures of symbols entering the field of view from above or below cannot be skew-corrected. <K537,line speed,symbol direction> Right 0 = Right 1 = Left
If a symbol enters the field of view from the left, it will be skewed as shown in the image below. The image is processed from top to bottom, meaning that the top of the symbol is captured first. The amount of skew is dependent on the speed at which the symbol moves through the imager’s field of view. The symbol below was captured at a line speed of 40 inches per second.
Additional Notes on Skew Correction • Autocalibration does not perform skew correction. It is assumed that during autocalibration the symbol is stationary, so skew correction is not required. • Images are corrected before they are processed. Therefore, if an image is still pending at the end of the read cycle, it will not have been skew-corrected.
MINI Hawk Xi High Performance Imager User Manual
10-25
Page 256
Morphological Pre-Processing
Morphological Pre-Processing Morphological Pre-Processing allows the user to select the method for processing images, and to choose the operator size for that method. Important: This command must be set to Enabled for Morphological Operation to function. Serial Cmd: Default: Options:
10-26
<K550,morphological pre-processing> Disabled 0 = Disabled 1 = Enabled
MINI Hawk Xi High Performance Imager User Manual
Page 257
Camera and IP Setup
Morphological Operation and Operator Size Morphological Operation Definition: Serial Cmd: Default: Options:
Morphological Operation allows the user to select the method for processing captured images. <K551,0,morphological operation,operator size> Erode 0 = Erode 1 = Dilate 2 = Open 3 = Close
Erode Erode increases the dark cell size of a symbol. Useful for increasing the dark cell size of a dark-on-light Data Matrix symbol.
Dilate Dilate increases the light cell size of a symbol. Useful for increasing the light cell size of a light-on-dark Data Matrix symbol.
MINI Hawk Xi High Performance Imager User Manual
10-27
Page 258
Morphological Operation and Operator Size
Open Open removes minor light defects of dark cells by performing a Dilate function followed by an Erode function.
Close Close removed minor dark defects of light cells by performing an Erode function followed by a Dilate function.
10-28
MINI Hawk Xi High Performance Imager User Manual
Page 259
Camera and IP Setup
Operator Size Definition: Serial Cmd: Default: Options:
Operator Size determines the size of the area or “pixel neighborhood” (measured in pixels) in which the morphological operation is being performed. <K551,0,morphological operation,operator size> Small 3 = Small (3 pixels by 3 pixels) 5 = Medium (5 pixels by 5 pixels) 7 = Large (7 pixels by 7 pixels)
MINI Hawk Xi High Performance Imager User Manual
10-29
Page 260
Morphological Operation and Operator Size
10-30
MINI Hawk Xi High Performance Imager User Manual