Page 181

I/O Parameters

ISO/IEC 16022 Symbol Quality Output 1 Note: Output On under Output 1 Parameters must be set to Symbol Quality for this output to function.

Under Output 1 Parameters, expand the Symbol Quality (ISO/IEC 16022) tree.

Output on Symbol Contrast Usage: Definition: Serial Cmd: Default: Options:

Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when Symbol Contrast Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Disabled 0 = Disabled 1 = Enabled

Output on Print Growth Usage: Definition: Serial Cmd: Default: Options:

Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when Print Growth Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Disabled 0 = Disabled 1 = Enabled

MINI Hawk Xi High Performance Imager User Manual

7-27

Page 182

ISO/IEC 16022 Symbol Quality Output 1

Output on Axial Non-Uniformity Usage: Definition: Serial Cmd: Default: Options:

Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when Axial Non-Uniformity Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Disabled 0 = Disabled 1 = Enabled

Output on Unused Error Correction Usage: Definition: Serial Cmd: Default: Options:

Lets the user know if symbol quality is less than acceptable. If enabled, toggles Output 1 to an active state when UEC Threshold is met. <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Disabled 0 = Disabled 1 = Enabled

Symbol Contrast Threshold Usage: Definition: Serial Cmd: Default: Options:

7-28

Lets the user set the acceptable level of symbol quality. Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D). <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Grade C 0 = Grade A 1 = Grade B 2 = Grade C 3 = Grade D

MINI Hawk Xi High Performance Imager User Manual

Page 183

I/O Parameters

Print Growth Threshold Usage: Definition: Serial Cmd: Default: Options:

Lets the user set the acceptable level of symbol quality. Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D). <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Grade C 0 = Grade A 1 = Grade B 2 = Grade C 3 = Grade D

Axial Non-Uniformity Threshold Usage: Definition: Serial Cmd: Default: Options:

Lets the user set the acceptable level of symbol quality. Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D). <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Grade C 0 = Grade A 1 = Grade B 2 = Grade C 3 = Grade D

Unused Error Correction Threshold Usage: Definition: Serial Cmd: Default: Options:

Lets the user set the acceptable level of symbol quality. Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D). <K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold> Grade C 0 = Grade A 1 = Grade B 2 = Grade C 3 = Grade D

MINI Hawk Xi High Performance Imager User Manual

7-29

Page 184

Diagnostics Output 1

Diagnostics Output 1 Note: Output On under Output 1 Parameters must be set to Diagnostic Warning for this output to function.

Under Output 1 Parameters, expand the Diagnostics tree.

Serial Cmd: Default: Options:

<K790,unused 1,service unit> 0 0 = Disabled

Service Unit When Diagnostic Warning is enabled, the Output On configuration has no effect. The output will remain active as long as one of the diagnostic warning conditions is met. The output will become inactive once it detects that there are no diagnostic warning conditions. Definition:

Serial Cmd: Default: Options:

7-30

Allows the user to set up the output to toggle to active when the service timer has expired. This condition will only be held for one service timer click. Note: This feature cannot be used if the imager is in a Continuous Read mode. <K790,unused 1,service unit> 0 0 = Disabled 1 = Enabled

MINI Hawk Xi High Performance Imager User Manual

Page 185

I/O Parameters

Configurable Output 2 Note: Output 2 has the same parameters and default settings as Output 1.

Serial Cmd:

<K811,output on,output state,pulse width,output mode>

Trend Analysis Output 2 Note: Output On under Output 2 Parameters must be set to Trend Analysis for this output to function.

Serial Cmd:

<K781,trend analysis mode,trigger evaluation period,number to output on>

ISO/IEC 16022 Symbol Quality Output 2 Note: Output On under Output 2 Parameters must be set to Symbol Quality for this output to function.

Serial Cmd:

<K801,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non- uniformity threshold,output on UEC,UEC threshold>

Diagnostics Output 2 Note: Output On under Output 2 Parameters must be set to Diagnostic Warning for this output to function.

Serial Cmd:

<K791,unused 1,service unit>

MINI Hawk Xi High Performance Imager User Manual

7-31

Page 186

Configurable Output 3

Configurable Output 3 Note: Output 3 has the same parameters and default settings as Output 1 and Output 2.

Serial Cmd:

<K812,output on,output state,pulse width,output mode>

Trend Analysis Output 3 Note: Output On under Output 3 Parameters must be set to Trend Analysis for this output to function.

Serial Cmd:

<K782,trend analysis mode,trigger evaluation period,number to output on>

ISO/IEC 16022 Symbol Quality Output 3 Note: Output On under Output 3 Parameters must be set to Symbol Quality for this output to function.

Serial Cmd:

<K802,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold>

Diagnostics Output 3 Note: Output On under Output 3 Parameters must be set to Diagnostic Warning for this output to function.

Serial Cmd:

7-32

<K792,unused 1,service unit>

MINI Hawk Xi High Performance Imager User Manual

Page 187

I/O Parameters

Power On/Reset Counts Note: Power On/Reset Counts is a read-only command.

Power-On Serial Cmd:

<K406,power-on,resets,power-on saves,power-on flash saves>

Power-On uses a 16-bit counter that increments each time the imager is powered-on.

Resets Serial Cmd:

<K406,power-on,resets,power-on saves,power-on flash saves>

Resets uses a 16-bit counter that increments each time the imager is reset. This value is reset at power-on.

Power-On Saves Serial Cmd:

<K406,power-on,resets,power-on saves,power-on flash saves>

Power-On Saves uses a 16-bit counter that increments each time an imager setting is saved for power-on with a <Z> command.

Power-On Flash Saves Serial Cmd:

<K406,power-on,resets,power-on saves,power-on flash saves>

Power-On Flash Saves uses a 16-bit counter that increments each time an imager setting is saved to the customer parameter section of flash memory with a <Zc> command.

MINI Hawk Xi High Performance Imager User Manual

7-33

Page 188

Time Since Reset

Time Since Reset Note: Time Since Reset is a read-only command.

Hours Serial Cmd: Default:

<K407,hours,minutes> 16-bit counter (0 to 65535)

Hours uses a 16-bit counter that increments every 60 minutes.

Minutes Serial Cmd: Default:

<K407,hours,minutes> 16-bit counter (0 to 60)

Minutes uses a 16-bit counter that increments every 60 seconds. Note: Time counts are reset at power-on, but not with an <A> or <Z> command.

7-34

MINI Hawk Xi High Performance Imager User Manual

Page 189

I/O Parameters

Service Message When Service Message is enabled, a message of up to 10 ASCII characters is sent whenever the system detects that the service timer’s limit has been reached. The service timer is reset at power-on, meaning that the service timer’s limit is the amount of time since last reset. Service timer increments can be set in seconds or minutes. Serial Cmd: Default: Options:

<K409,status,service message,threshold,resolution> 0 0 = Disabled 1 = Enabled

Service Message Serial Cmd: Default: Options:

<K409,status,service message,threshold,resolution> SERVICE An ASCII string between 1 and 10 characters.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K409h,,3C> For >: <K409h,,3E> For , : <K409h,,2C>

Threshold Serial Cmd: Default: Options:

<K409,status,service message,threshold,resolution> 300 (5 minutes) 1 to 65535

Resolution Serial Cmd: Default: Options:

<K409,status,service message,threshold,resolution> Seconds 0 = Seconds 1 = Minutes

MINI Hawk Xi High Performance Imager User Manual

7-35

Page 190

Frame Information

Frame Information Output Frame Number Serial Cmd: <K734,output frame number,output coordinates> Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Disabled When Output Frame Number is set to Disabled, the frame number is not output as part of the symbol data.

Enabled When Output Frame Number is set to Enabled, the number of the frame in which the symbol was first decoded is attached to the symbol output information. The output format is “Fnnn”, where “nnn” is a 3-digit decimal value from 0 to 255. The frame number rolls over to 0 once it passes 255. If this feature is enabled, the frame information will follow the symbol data, and it will precede any symbol quality data (if symbol quality settings are enabled - see Symbol Quality Separator). The symbol quality separator is located between the end of the already-formatted data and the “F” that precedes the frame number.

Output Coordinates Serial Cmd: <K734,output frame number,output coordinates> Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Disabled When Output Coordinates is set to Disabled, the coordinates are not output as part of the symbol data.

Enabled When Output Coordinates is set to Enabled, the four sets of object coordinates for the first successfully decoded symbol are attached to the symbol data output in the following format: “(nnn,mmm)”, where “nnn” is a 3-digit X-coordinate and “mmm” is a 3-digit Y-coordinate. The validation separator is located between the end of the already formatted data and the first coordinate point. The point with the lowest X + Y sum will be output first, followed by the next three points in a clockwise direction. Example: (032,040)(287,056)(287,279)(048,271)

7-36