Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 19 of 43

Quadrus MINI Imager User's Manual, pages 181 to 190

Pages 181 to 190 of 424

The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MINI 6300

Page 181

7 I/O Parameters Contents I/O Parameters by ESP ................................................................................................................ 7-2 I/O Parameters Serial Commands ............................................................................................... 7-3 Symbol Data Output ..................................................................................................................... 7-4 No Read Message........................................................................................................................ 7-7 Bad Symbol Message ................................................................................................................ 7-10 No Symbol Message .................................................................................................................. 7-10 1D/Stacked Symbology Qualification ......................................................................................... 7-11 2D Symbology Qualification ....................................................................................................... 7-12 Read Duration Output ................................................................................................................ 7-18 Output Indicators ........................................................................................................................ 7-19 Beeper........................................................................................................................................ 7-23 LED Configuration ...................................................................................................................... 7-24 Serial Verification ....................................................................................................................... 7-25 EZ Button ................................................................................................................................... 7-27 EZ Button Modes........................................................................................................................ 7-29 Configurable Output 1 ................................................................................................................ 7-31 Trend Analysis Output 1............................................................................................................. 7-34 ISO/IEC 16022 Symbol Quality Output 1 ................................................................................... 7-37 Diagnostic Output 1.................................................................................................................... 7-40 Configurable Output 2 ................................................................................................................ 7-41 Trend Analysis Output 2............................................................................................................. 7-41 ISO/IEC 16022 Symbol Quality Output 2 ................................................................................... 7-41 Diagnostic Output 2.................................................................................................................... 7-41 Configurable Output 3 ................................................................................................................ 7-42 Trend Analysis Output 3............................................................................................................. 7-42 ISO/IEC 16022 Symbol Quality Output 3 ................................................................................... 7-42 Diagnostic Output 3.................................................................................................................... 7-42 Power-On/Reset Counts ............................................................................................................ 7-43 Time Since Reset ....................................................................................................................... 7-44 Service Message........................................................................................................................ 7-45 Frame Information ...................................................................................................................... 7-46 Image Output.............................................................................................................................. 7-47 Database Identifier Output ......................................................................................................... 7-50 Quality Output ............................................................................................................................ 7-51 Configuring EZ Trax Output ....................................................................................................... 7-52

This section includes instructions on setting up conditions for changing input/output electrical transitions for control of the imager’s internal and external devices. A discrete I/O (in/out) signal is an electrical transition from one voltage level to another so that digital switching can occur. Quadrus MINI Imager User’s Manual

7-1

Page 182

I/O Parameters by ESP

I/O Parameters by ESP

Click this button to bring up the App Mode view.

Click this button to bring up the I/O Parameters tree control.

To change a setting, double-click the setting and use your cursor to scroll through the options.

To open nested options, single-click the +.

7-2

Quadrus MINI Imager User’s Manual

Page 183

I/O Parameters

I/O Parameters Serial Commands Power On/Reset Counts

<K406,power-on,resets,power-on saves,power-on flash saves>

Time Since Reset

<K407,hours,minutes>

Service Message

<K409,status,service message,threshold,resolution>

Serial Verification

<K701,serial command echo status,serial command beep status,control/hex output>

Beeper

<K702,status>

Quality Output

<K704,quality output separator,decodes/trigger status>

Symbol Data Output

<K705,symbol data output status,when to output>

Read Duration Output

<K706,status,separator>

No Read Message

<K714,status,message>

Bad Symbol Message

<K715,[unused],message>

No Symbol Message

<K716,[unused],message>

1D/Stacked Symbology Qualification

<K717,minimum number of bars,minimum number of qualified scan lines,start/stop status>

2D Symbology Qualification

<K718,finder pattern status,symbol size status,symbol size 1,symbol size 2,symbol size tolerance,dimension status,dimension 1,dimension 2,dimension tolerance,orientation status,orientation value>

Frame Information

<K734,output frame number,output coordinates>

LED Configuration

<K737,LED mode,ISO/IEC 16022 grade>

Image Output Target/Flood LEDs

<K739,image output mode,communication port,file format,JPEG quality> <K750,green flash LED status,target pattern LED status,green flash duration>

EZ Trax Output

<K757,comm port,image mode,image format,JPEG quality,object info output,grade output>

Database Identifier Output

<K759,status,separator>

EZ Button

<K770,global status,default on power-on,load configuration database, save for power-on>

EZ Button Modes

<K771,single beep,two beeps,three beeps,four beeps>

Trend Analysis Output 1

<K780,trend analysis mode,trigger evaluation period,number to output on>

Trend Analysis Output 2

<K781,trend analysis mode,trigger evaluation period,number to output on>

Trend Analysis Output 3

<K782,trend analysis mode,trigger evaluation period,number to output on>

Diagnostic Output 1

<K790,unused 1,service unit>

Diagnostic Output 2

<K791,unused 1,service unit>

Diagnostic Output 3

<K792,unused 1,service unit>

ISO/IEC 16022 Symbol Quality Output 1

<K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold>

ISO/IEC 16022 Symbol Quality Output 2

<K801,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold>

ISO/IEC 16022 Symbol Quality Output 3

<K802,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold>

Configurable Output 1

<K810,output on,output state,pulse width,output mode>

Configurable Output 2

<K811,output on,output state,pulse width,output mode>

Configurable Output 3

<K812,output on,output state,pulse width,output mode>

Quadrus MINI Imager User’s Manual

7-3

Page 184

Symbol Data Output

Symbol Data Output Symbol Data Output Status Note: Symbol Data Output relates to data and should not be confused with Outputs 1, 2, and 3 listed in the Output Parameters which describe output states and functions. Usage: Definition: Serial Cmd: Default: Options:

Useful when the host needs symbol data only under certain conditions. Defines the conditions under which decoded symbol data is transmitted to the host. <K705,symbol data output status,when to output> Good Read 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read

Note: Symbol Data Output Status, if set to Match or Mismatch, will not take effect unless Matchcode Type is enabled and a master symbol is loaded into memory.

Disabled Usage:

Definition:

It is useful when an application only needs to use the discrete outputs and can allow the imager to do the decision-making. When Disabled, the host does not need the symbol data and the communication lines are used only for setup and status checks. When set to Disabled, the imager will not transmit any data that is generated during a read cycle (symbols, No Reads, etc.)

Match Usage:

Definition:

Match is used in an application that requires specific symbol information and needs to sort, route, or verify based on matching the specific symbol data. When set to Match, the imager transmits symbol data whenever a symbol matches a master symbol. However, if Matchcode Type is Disabled, it transmits on any good read.

Note: A No Read can still be transmitted if Enabled.

Mismatch Usage: Definition:

Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container. With Mismatch enabled, the imager transmits symbol data whenever the symbol data information does NOT match the master symbol.

Note: A No Read can still be transmitted if Enabled. 7-4

Quadrus MINI Imager User’s Manual

Page 185

I/O Parameters

Good Read Usage:

Definition:

Good Read is used when an application requires all symbol data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified. With Good Read enabled, the imager transmits symbol data on any good read regardless of Matchcode Type setting.

Note: A No Read can still be transmitted if Enabled.

Quadrus MINI Imager User’s Manual

7-5

Page 186

Symbol Data Output

When to Output Symbol Data Definition: Serial Cmd: Default: Options:

This command allows the user to choose when symbol data can be sent to the host. <K705,symbol data output status,when to output> As Soon As Possible 0 = ASAP 1 = End of Read Cycle

As Soon As Possible Usage:

Definition:

As Soon As Possible is useful in applications in which symbol data needs to be moved quickly to the host, typically when the host is making decisions based on symbol data. Enabling As Soon As Possible causes symbol data to be sent to the host immediately after a symbol has been successfully decoded.

Note: More than one decode might in fact be required to qualify as a good read, depending on how Decodes Before Output is set.

End of Read Cycle Usage: Definition:

End of Read Cycle is useful in timing-based systems in which the host is not ready to accept data at the time that it is decoded. Enabling End of Read Cycle means that symbol data does not get sent to the host until the read cycle ends with a timeout or new trigger.

End of read cycle

Start of read cycle Read cycle duration Host activates trigger

7-6

This is when host expects output

Quadrus MINI Imager User’s Manual

Page 187

I/O Parameters

No Read Message Usage: Definition:

Used in applications where the host needs serial verification that a symbol has not been read and especially useful in new print verification. When enabled, and if no symbol has been decoded before timeout or the end of the read cycle, the No Read message will be transmitted to the host.

No Read Message Mode Serial Cmd: Default: Options:

<K714,No Read message status,No Read message> Enabled 2 = Detailed No Read Message 0 = Disabled 1 = Enabled

Disabled Only symbol data is output after a read cycle.

Enabled When the imager is in a triggered mode, a No Read message will be appended for each failed read attempt.

Detailed No Read Message Important: In the case where the conditions set in Bad Symbol/No Symbol Qualification are met, then the Bad Symbol or No Symbol message output will override the No Read Message or the Detailed No Read Message, if either is enabled. Note: Detailed No Read Message is not supported when Q-Mode is enabled. Usage: Definition:

Use this option to cover more detailed reasons for decode failures. Outputs a No Read message followed by an additional message (an Image Processing Results Code) indicating the reason a symbol failed to decode.

For example, in the following output: “No Read d_1, E_2”, d and E are symbology i.d.s for Data Matrix and UPC respectively. The message means that Data Matrix and UPC are enabled (and other symbologies are not), and that both failed to decode. The reason for the failing Data Matrix is 1 and the reason for the failing UPC is 2. The first part of these numbers (preceding the dot) is the relevant number and is interpreted here:

2D Symbols: 1. Failed to locate symbol (no finder pattern). 2. Failed to locate four corners or failed to qualify user defined dimensions (in pixels). 3. Failed to locate clock patterns or failed to qualify user defined orientation (0-359 degree). 4. Failed to validate clock patterns or failed to qualify user defined symbol size (clock element count). 5. Failed to decode symbol.

Quadrus MINI Imager User’s Manual

7-7

Page 188

No Read Message

Linear (1D) Symbols: 1. Failed user defined minimum number of bars. 2. Failed to decode start/stop character (doesn’t apply to UPC, GS1 DataBar (RSS), MicroPDF417, or Pharmacode). 3. Failed user defined minimum number of scan lines that qualify for the minimum number of bars. 4. Failed to decode. 5. Failed to decode UPC supplemental.

7-8

Quadrus MINI Imager User’s Manual

Page 189

I/O Parameters

No Read Message Definition: Serial Cmd: Default: Options:

Any combination of ASCII characters can be defined as the No Read message. <K714,No Read message status,No Read message> No Read A string of up to 64 characters.

Note: No Read Message will only be transmitted if Symbol Data Output is set to Match, Mismatch, or Good Read. No Read Message can be set to any ASCII character. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K714h,,3C> For >: <K714h,,3E> For , : <K714h,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.

Quadrus MINI Imager User’s Manual

7-9

Page 190

Bad Symbol Message

Bad Symbol Message Note: Bad Symbol Message is not supported when Q-Mode is enabled. Usage:

Definition:

Serial Cmd: Default: Options:

Useful in determining if a symbol is present and if user defined requirements for that symbol are met. Can tell the user if a qualified symbol is present but not decodable. Sets the requirements that will qualify an object or a symbol before outputting a decode or message. When enabled, sends a message to the host whenever an object meets the qualifications setup but is not decoded. Note: When Symbology Identifier is enabled, the Bad Symbol message is preceded by the identifier for the symbology being used. <K715,[unused],message> BAD_SYMBOL Up to 64 ASCII characters.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K715h,,3C> For >: <K715h,,3E> For , : <K715h,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.

No Symbol Message Note: No Symbol Message is not supported when Q-Mode is enabled. Usage:

Definition:

Serial Cmd: Default: Options:

Useful in determining if a symbol is present and if user defined requirements for that symbol are met. Can tell the user if an object does not qualify as a symbol. Sets the requirements that will qualify an object or a symbol before outputting a decode or message. When enabled, sends a message to the host whenever an object meets the qualifications setup but is not decoded. Note: When Symbology Identifier is enabled, the No Symbol message is preceded by the identifier for the symbology being used. <K716,[unused],message> NO_SYMBOL Up to 64 ASCII characters.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K716h,,3C> For >: <K716h,,3E> For , : <K716h,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values. 7-10

Quadrus MINI Imager User’s Manual