Page 161

Using ReadRunner

–

Light, Allows up to 2 retries using optionally different Decoder parameters. On the second retry, a new picture is taken using the same photometry parameters; however the lighting and/or strobe mode can be specified directly in the UI. This mode is a subset of the RETRY PID List w/Acquire mode. This mode retries in the order PID0 with Lighting ON, and then PIDn with External Light.

For additional information about Retry Modes, see “Retry Modes” on page 3-6.

Extended PID List

Note: The camera is sent the entire, defined list, but will only process retries on PIDs up to the point that it sees the first 0 in the list. There are two modes of retry list operation: •

PID List, A single image acquisition is performed and decodes are attempted using the settings for each PID in the list, always starting at the first and working through to the end of the list. For performance reasons, it is important to order the list in terms of diminishing probability of decode success so that the chance of decode on the first one or two PIDs will be optimized. Subsequent reads proceed from the list position that the last read finished on.

•

PID List w/Acquire, Cycles through the PID list, taking new images until a successful Acquire/Decode pair happens.

Both modes have process specific considerations that need to be taken into account before choosing which mode best suits a specific application. For example, if the resulting Data Valid line controls when to move a conveyor belt to advance to the next part, you would not want to do a re-acquire, as the part would move on without trying the other PIDs. In this case, you would want to run without acquire so that all the PIDs are tried on the one image, and then give one final result.

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4-51

4 ReadRunner

The PID List and PID List w/Acquire retry modes allow up to 15 PIDs with specific decoder settings to be tried. The additional PID list entry slots become visible in the user interface as they are populated. A value of 0, at any point, terminates the list

Page 162

Chapter

4

ReadRunner

PID List w/ Acquire is used in situations where various manual photometry settings are saved in different PIDs and a new image needs to be taken before the decoding process is started.

Read Timeout This parameter specifies the time to spend searching and decoding a symbol (i.e., Data Matrix or Barcode). If Data Matrix reading is enabled, regardless of whether or not Barcode reading is enabled, the Read Timeout must be set in either of two ways. When Probe Direction for Data Matrix is set to: •

The default (HORI_VERT or VERT_HORI), you must set Read Timeout based on the following scenario. If the Data Matrix and Barcode reading takes x milliseconds to complete, set Read Timeout to at least 2 times the time in milliseconds. This allows the vertical probe to fail and the horizontal probe to complete successfully.

•

HORIZONTAL only, VERTICAL only, or CRISS_CROSS, you must set Read Timeout based on the following scenario. If the Data Matrix and Barcode reading takes x milliseconds to complete, set Read Timeout to at least 1 time the time in milliseconds. Note: When vertical is enabled, HORI_VERT and VERT_HORI are ignored internally and CRISS_CROSS is used for robustness.

Report Budget This parameter specifies the amount of time in msec (default is 5) used to send results (decode string, image, report) over TCP/IP. It is scheduled in such a way that the read speed remains deterministic. This time gets added to the processing time for every part and, therefore, impacts the maximum reads per second of the camera. This time can be reduced when sending results via a serial connection ONLY to gain a few more PPM, if necessary. However, be aware that the report budget is also used in Demo Mode to allow the camera to send images and reports to connected clients for the purpose of monitoring (Ethernet connections). Setting this parameter to zero for very fast pipeline applications may have an adverse effect on ReadRunner responsiveness, and may cause it to stop receiving images and reports. Therefore, it is recommended that this value be set to at least 1 msec or more.

4-52

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 163

Using ReadRunner

Triggers To specify a trigger: 1.

Press Ctrl+F6, or select IO Settings from the Settings menu.

2.

Click Yes when asked if you wish to control camera X. ReadRunner displays the IO Settings window, as shown in Figure 4–41.

FIGURE 4–41. I/O Settings Window

ReadRunner

4 v2.4.1, Nov 2008

3.

Select Use Trigger on OPTO IN 1.

4.

From the Triggering Edge pull down menu, select one of the following triggering edges:

HawkEye™ 1500 Series User Manual

4-53

Page 164

Chapter

4

ReadRunner

–

Low to High

–

High to Low

–

Both

5.

Click Apply.

6.

Click OK.

Advanced I/O To specify the I/O behavior mode: 1.

Press Ctrl+F6, or select IO Settings from the Settings menu.

2.

Click Yes when asked if you wish to control camera X. ReadRunner displays the IO Settings window, as shown in Figure 4–42.

4-54

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 165

Using ReadRunner

FIGURE 4–42. I/O Settings Window - Modes Displayed

ReadRunner

4

3.

v2.4.1, Nov 2008

From the IO Behavior Mode pull down menu, select one of the following: –

Disabled

–

Pass/Fail Only - Full Handshake, Handshake mode with OPT1 = Pass, OPT2 = Fail.

–

Pass/Fail Only - Pipelined, PULSE/PIPELINED mode with OPT1 = Pass, OPT2 = Fail.

HawkEye™ 1500 Series User Manual

4-55

Page 166

Chapter

4

ReadRunner

–

Data Valid - Full Handshake, Handshake mode with OPT1 = Pass, OPT2 = Fail, OPT3 = Data Valid.

–

Data Valid - Pipelined, PULSE/PIPELINED mode with OPT1 = Pass | Fail, OPT3 = Data Valid.

–

DV - 2 Line Verify - Full HS, GOOD, FAIR, POOR multiplexed on two assigned lines plus Data Valid.

–

DV - 3 Line Verify - Full HS, GOOD, FAIR, POOR, Data Valid, lines are assigned

–

DV - 2 Line Verify - Pulse, GOOD, FAIR, POOR multiplexed on two assigned lines plus Data Valid.

–

DV - 3 Line Verify - Pulse, GOOD, FAIR, POOR, Data Valid, lines are assigned.

4.

Click Apply.

5.

Click OK. When you select an IO Mode, ReadRunner displays suggested line definitions to guide you through the next step (IO Assignment), as shown in Figure 4–43. See also Table 4–5.

4-56

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 167

Using ReadRunner

FIGURE 4–43. I/O Settings Window - Suggested Line Definitions

ReadRunner

4 Suggested Line Definitions

The default IO Assignment that has been pre-configured uses the same physical lines that were used in earlier versions of the HawkEye™ software.

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4-57

Page 168

Chapter

4

ReadRunner

Note: I/O points are NOT set automatically! You must set them manually. TABLE 4–5. Suggested Line Definitions

I/O Mode

Suggested Line Definitions

Data Valid - Full Handshake

Pass, Fail, DV, RTE

Data Valid - Pipelined

Pass, Fail, DV, RTE

DV - 2 Line Verify - Full HS

DV, RTE, Good, Poor

DV - 2 Line Verify - Pulse

DV, RTE, Good, Poor

DV - 3 Line Verify - Full HS

DV, RTE, Good, Fair, Poor

DV - 3 Line Verify - Pulse

DV, RTE, Good, Fair, Poor

Pass/Fail Only - Full Handshake

Pass, Fail, DV, RTE

Pass/Fail Only - Pipelined

Pass, Fail, DV, RTE

6.

Click IO Assignment. ReadRunner displays the IO Assignment window, as shown in Figure 4–44.

4-58

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 169

Using ReadRunner

FIGURE 4–44. I/O Assignment Window

ReadRunner

4

Each of the configurable lines is displayed with the polarity, keyword name, and behavior desired. Note: A given keyword name may only be configured for one physical line at a time.

Supported Keyword Names The supported keyword names are: • v2.4.1, Nov 2008

PASS, May also represent a MATCHED state if a Match Mode is enabled.

HawkEye™ 1500 Series User Manual

4-59

Page 170

Chapter

4

ReadRunner

•

FAIL, May also represent a NO MATCH state if a Match Mode is enabled.

•

DV, Data Valid - This line is set on when results of a decode have been set and other lines are stable.

•

RTE, Real Time Error - Indicates trigger overflows, timeout errors, and network failures.

•

GOOD, (Used by the Verification option).

•

FAIR, (Used by the Verification option).

•

POOR, (Used by the Verification option).

•

ANGLE_FAILURE, Signals when the measured angle is outside of your process limits.

•

4-60

–

Default Behavior = NOMINAL_DEV

–

Nominal Value = 0

–

Deviation Value = 15

LOCATE_FAILURE, May be used as an overall indicator or masked to signal particular types of locate failures. –

Default Behavior = MASK

–

Mask Value = &H7FFFFFF

•

DECODE_FAILURE, If used when Match Mode is enabled, it allows you to distinguish between NO MATCH with a successful Decode and NO MATCH with an unsuccessful Decode.

•

MATCH_FAILURE, When used in conjunction with the PASS signal when a Match Mode is enabled, provides two outputs that differ only in whether the match passed or failed. Both PASS and MATCH_FAILURE indicate that the symbol was successfully decoded.

•

READY, This keyword indicates the online status of the camera. This output could be used to indicate to a PLC that the camera is ready to accept commands and trigger inputs.

•

READ_A, This keyword configures the line as an input to trigger a read with a specified PID, trigger edge, latch, and delay values.

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008