Page 151

Using ReadRunner

“*string” matches “string”

“?string” matches “?string” “?string” matches “*string” “?string” matches “Xstring”

Setting Up Serial Number Matching The Camera Report window (Figure 4–33) displays detailed information (Cycles, Decodes, and Locates, and so on) about what the HawkEye™ 1500 camera is reading.

4 ReadRunner

FIGURE 4–33. ReadRunner Camera Report Window

Serial Number Matching disabled

If you also want to display detailed information about the number of passed and failed serial number matches, you have to specify detailed information in the Match Mode Setup window. To set up serial number matching: 1.

Press Ctrl+O, or select Match Mode Settings from the Settings menu. ReadRunner displays the Match Mode Setup window, as shown in Figure 4–34.

2.

Click to enable Enable Serial Number Matching. ReadRunner displays the Enable Serial Number Matching text box (Figure 4–34).

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4-41

Page 152

Chapter

4

ReadRunner

FIGURE 4–34. Serial Number Matching Window

3.

Specify the following: –

Start Count, This is the starting serial number.

–

Increment, This indicates by how much the serial number will increase each time it is encountered.

–

First Character Position, This indicates where in a string the actual serial number begins.

–

Last Character Position, This indicates where in a string the actual serial number ends.

For example, assume a part number looks like the following: ABCDEFG123456-101 Last Character Position First Character Position

Note: Serial match supports 9 digits.

4-42

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 153

Using ReadRunner

Figure 4–35 shows the correct settings for serial number matching, assuming a serial number that increments by one each time. FIGURE 4–35. Serial Number Matching Window

After serial number matching is enabled, your Camera Report window will look similar to the one displayed in Figure 4–36. FIGURE 4–36. ReadRunner Camera Report Window

Serial Number Matching enabled v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4-43

ReadRunner

4

Page 154

Chapter

4

ReadRunner

Specifying... Preferences The Preferences window contains three tabs. The Report Connectivity tab (Figure 4–37) allows you to specify the rate at which report information is sent to the Reports window. FIGURE 4–37.

•

•

4-44

Preferences Window, Report Connectivity Tab

Report Rate, Specifies the rate at which data is sent to the Reports window. –

Maximum, Send report information as fast as possible.

–

1 per second, At most, send report information once per second.

–

2 per second, At most, send report information twice per second.

–

4 per second, At most, send report information four times per second.

–

8 per second, At most, send report information eight times per second.

Image Rate, Specifies the rate at which images are sent to the camera. –

Maximum, Send images as fast as possible.

–

1 per second, At most, send an image once per second.

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 155

Using ReadRunner

– •

2 per second, At most, send an image twice per second.

When in control, use maximum transfer rates, Send report information and images as fast as possible.

The General tab (Figure 4–38) allows you to specify the format and location of the save images. FIGURE 4–38.

Preferences Window, General Tab

ReadRunner

4

•

Image Save Format, Specifies the format of the saved image, either TIFF (*.tif) or Bitmap (*.bmp).

•

Image Save Directory, Specifies the directory for the saved image.

The Image Display tab (Figure 4–39) allows you to specify the color of Pass and Fail information, and the font, font style, and font size of result text.

v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

4-45

Page 156

Chapter

4

ReadRunner

FIGURE 4–39.

Preferences Window, Image Display Tab

•

Pass Color, Specifies the color of the information that passes. Click ... to display the color palette.

•

Fail Color, Specifies the color of information that fails. Click ... to display the color palette.

•

Result Text, When you click Font, ReadRunner displays fonts, font styles, and font sizes from which you can choose what the result text will look like. Click Color to display the color palette.

•

Display text on top of screen, Click this option to optionally have the decode strings placed at the top of the image instead of over the decoded symbol. This allows images to be inspected for defects.

Application Modes The application mode specifies the basic setup that the HawkEye™ 1500 camera will use for reading. To specify the application mode:

4-46

1.

Press Ctrl+M, or select Application Mode from the Settings menu.

2.

Click Yes when asked if you wish to control camera X. ReadRunner displays the Application Mode window, as shown in Figure 4–40.

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 157

Using ReadRunner

FIGURE 4–40. Application Mode Window

ReadRunner

4

3.

Select one of the following modes: Note: When you change the Application mode, a dialog box will be displayed asking you to confirm the changes corresponding to the new Application mode.

v2.4.1, Nov 2008

–

Demo, This mode demonstrates the capabilities of the HawkEye™ 1500 camera. Settings include continuous triggers, no retries, illumination constantly on, and auto photometry.

–

Motion, This mode scans a symbol when it moves within the HawkEye™ 1500’s field of view. Because the parts are in motion, there is no time for the automatic calculation of photometry values. Thus, automatic photometry is off. You must specify the exposure and gain settings manually. A trigger is supplied (through the I/O connector) to the camera by a sensor device. In addition, the Lighting selection will be

HawkEye™ 1500 Series User Manual

4-47

Page 158

Chapter

4

ReadRunner

Power-strobe. This selection allows the parts to be moving at a very high speed, where short exposure times are desired. –

Stop and Scan, This mode scans a symbol when it stops within the HawkEye™ 1500’s field of view. A trigger is supplied to the camera by a sensing device (not included as standard equipment) when the symbol is in place. The trigger signal is supplied through the I/O connector. The illumination is set to strobe, and the automatic photometry is on. When the trigger is applied, the HawkEye™ 1500 camera will set the exposure and read the symbol.

–

Supermarket, This is often referred to as Presentation Mode. Parameters are set similarly to Demo mode, except that an inter-symbol wait time (ISWT) is imposed. This means that, when a symbol is presented to the HawkEye™ 1500’s field of view, it will be read once. The same symbol cannot be read again until the symbol is removed from the field of view for at least the indicated ISWT. A different symbol, when presented to the camera, will be read immediately.

You may make modifications to any of these application modes. Note: When Verification is set to AIM DPM-1-2006, Application, Lighting, and Retry Mode are disabled. The remainder of this section on Application Mode describes: •

“Lighting” on page 4-48

•

“Retry Modes” on page 4-49

•

“Extended PID List” on page 4-51

•

“Read Timeout” on page 4-52

•

“Report Budget” on page 4-52

•

“Triggers” on page 4-53

•

“Advanced I/O” on page 4-54

Lighting The lighting type specifies what kind of lighting the HawkEye™ 1500 camera will be using. To specify the lighting type:

4-48

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 159

Using ReadRunner

Press Ctrl+M, or select Application Mode from the Settings menu.

2.

Click Yes when asked if you wish to control camera X. ReadRunner displays the Application Mode window.

3.

Using the pull down menu, specify one of the following for lighting: –

Off, Use ambient lighting.

–

On, Use constant lighting. This is the default.

–

Strobe, Use strobe lighting.

–

Power Strobe, Use power strobed lighting.

–

On w/Power Strobe, This selection keeps the lighting on at all times but, when the camera is exposing, the Power Strobe intensity is supplied. Usually, this selection is chosen to reduce the effects of strobing that can cause adverse effects to humans when in the physical presence of the camera.

–

External, Use external lighting with external strobe on GPIO 1.

–

On & External, Use constant lighting with external strobe on GPIO 1.

–

Strobe & Ext, Use strobe lighting with external strobe on GPIO 1.

–

Power Strobe & Ext, Use power strobe lighting with external strobe on GPIO 1.

–

On/PowerStrb/Ext, This selection keeps the lighting on at all times but, when the camera is exposing, the Power Strobe intensity is supplied. The external strobe is on GPIO 1. Usually, this selection is chosen to reduce the effects of strobing that can cause adverse effects to humans when in the physical presence of the camera.

Retry Modes The retry mode specifies whether or not there will be multiple attempts, the number of attempts, and the time limit. To specify the retry mode:

v2.4.1, Nov 2008

1.

Press Ctrl+M, or select Application Mode from the Settings menu.

2.

Click Yes when asked if you wish to control camera X. ReadRunner displays the Application Mode window.

HawkEye™ 1500 Series User Manual

4-49

4 ReadRunner

1.

Page 160

Chapter

4

ReadRunner

3.

From the Retry Mode pull down menu, specify one of the following: –

None, Sets the read cycle to single attempt mode. This is the default.

–

Time, Set the read cycle to multiple attempts within the specified time limit. Range: 1500 - 60000ms

–

Count, Set the read cycle to a specified number of attempts. Range: 1 - 15

–

RETRY input Duration, Retries will continue while the state of the assigned RETRY input line remains high. Note: PID, Trigger Edge, Latch and Delay settings are ignored on this line.

–

Intersymbol Wait, When an Intersymbol Wait time is specified, leaving a symbol under the camera will produce a single result. A new result is produced only: •

If the same symbol data is NOT read for at least as long as the intersymbol wait period OR

• –

If a new symbol data is read

PID List, Allows each retry to use different decoder and preprocessing parameters without taking a new picture for each retry. Up to 15 PIDs can be used (5 retries). This mode retries in the order List 1 through List 15, and DOES NOT take a new picture each time. Note: See “Extended PID List” on page 4-51.

–

PID List w/Acquire, Allows each retry to use different decoder and/or preprocessing parameters while taking a new Picture for each retry. Up to 15 PIDs can be used (5 retries). This mode retries in the order List 1 through List 15, taking a new picture each time. Note: See “Extended PID List” on page 4-51.

4-50