The text of a manual · part 11 of 34
HawkEye 1500 Series User Manual, pages 101 to 110
Pages 101 to 110 of 338
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan HE1510, RVSI CiMatrix HE1510 and Siemens HE1510
Page 101
HawkEye™ 1500 I/O Operations
FIGURE 3–12. DV - 3 Line Verify - Full HS
3
1
Trigger Acquire Decode
3 HawkEye™ 1500 Series Overview
Present Good Fair Poor DV Setup Time 4 2
Notes: 1.
When DV is false, you can start read by asserting TRIG.
2.
When read is completed, reader sets the Good / Fair / Poor / Fail state and asserts DV after 2ms setup time.
3.
User accepts the Good / Fair / Poor / Fail state result and then negates TRIG.
4.
Reader detects TRIG negated and then negates DV.
TABLE 3–3. Three Line Multiplex of Verification Results
Line Keyword Name v2.4.1, Nov 2008
State
Good
Fair
Poor
Good
On
Off
Off
Fair
Off
On
Off
Poor
Off
Off
On
Fail
Off
Off
Off
HawkEye™ 1500 Series User Manual
3-27
Page 102
Chapter
3
HawkEye™ 1500 Series Overview
DV - 2 Line Verify, Pulse The Data Valid - Pipelined Mode drives the Good and Poor lines when the results of the verification are completed (see Table 3–4 for the line states of Good, Fair, Poor, and Fail). This mode then drives the Data Valid line for the pre-determined duration to indicate that the level on the Good and Poor lines is valid. The line will be set to the polarity for an indicated duration. You can configure the duration of the signal by using the IO_MODE command. FIGURE 3–13. DV - 2 Line Verify - Pulse
1
Trigger Acquire Decode assert negate time time
Present Good Poor DV Setup Time
2
3
4
Notes:
3-28
1.
User asserts Trigger (user can re-trigger after acquisition is complete).
2.
When read is complete, reader sets the Good / Fair / Poor / Fail state and asserts DV after 2 ms set-up time.
3.
Reader negates DV after user programmed “signal duration” time (new decode can start).
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 103
HawkEye™ 1500 I/O Operations
4.
Reader can assert DV again only after an additional “signal duration time.”
TABLE 3–4. Two Line Multiplex of Verification Results
Line Keyword Name Good
Poor
Good
On
On
Fair
On
Off
Poor
Off
On
Fail
Off
Off
3
DV - 3 Line Verify, Pulse The Data Valid - Pipelined Mode drives the Good, Fair, and Poor lines when the results of the verification are completed (see Table 3–5 for the line states of Good, Fair, Poor, and Fail). This mode then drives the Data Valid line for the predetermined duration to indicate that the Good, Fair, and Poor lines are valid and stable. The line will be set to the polarity for an indicated duration. You can configure the duration of the signal by using the IO_MODE command.
v2.4.1, Nov 2008
HawkEye™ 1500 Series User Manual
3-29
HawkEye™ 1500 Series Overview
State
Page 104
Chapter
3
HawkEye™ 1500 Series Overview
FIGURE 3–14. DV - 3 Line Verify - Pulse
1
Trigger Acquire Decode assert negate time time
Present Good Fair Poor DV Setup Time
2
3
4
Notes:
3-30
1.
User asserts Trigger (user can re-trigger after acquisition is complete).
2.
When read is complete, reader sets the Good / Fair / Poor / Fail state and asserts DV after 2 ms set-up time.
3.
Reader negates DV after user programmed “signal duration” time (new decode can start).
4.
Reader can assert DV again only after an additional “signal duration time.”
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 105
Formatted Output & Audio
TABLE 3–5. Three Line Multiplex of Verification Results
Line Keyword Name Good
Fair
Poor
Good
On
Off
Off
Fair
Off
On
Off
Poor
Off
Off
On
Fail
Off
Off
Off
3
Formatted Output & Audio The HawkEye™ 1500 supports formatted output via the serial port as well as through TCP/IP. You can configure the camera to output custom text, optionally with headers and footers, based on pass/fail status and even specific failure status. This data is then transmitted to the serial port and any TCP connections on port 49098. The camera supports different pass/fail criteria for outputting data. This includes Decode Pass, Decode Fail, Locate Fail, Match Pass, Match Fail, and Runtime Error. Runtime errors include trigger overruns, decoder overruns, acquisition timeouts, or network connection errors. Each type of output has an associated format string. Within this string, you can output specific characters (ABCD, 1234, etc.), or non-printable characters (CR, LF, TAB). Non-printable characters are denoted by using a backslash (“\”) followed by the hexadecimal value of the non-printable. Some common non-printable characters include:
v2.4.1, Nov 2008
•
\00, NULL character
•
\09, TAB character (TAB)
•
\0A, Line Feed (LF)
•
\0C, Form Feed (FF)
•
\0D, Carriage Return (CR)
HawkEye™ 1500 Series User Manual
3-31
HawkEye™ 1500 Series Overview
State
Page 106
Chapter
3
HawkEye™ 1500 Series Overview
You can also use keywords to expand specific pieces of data within the output string. These keywords include: ANGLE, CHECKSUM, DATA, DATAHEX, DETAILED, PID#, TIMESTAMP, VERI_1_IAQG, VERI_AIMDPM, VERI_DETAIL, VERI_FORMATTED, VERI_GRADE, VERI_STATUS, UII_ONLY, and UII_WITH_INFO. For detailed information about these keywords, see “Format String Keywords” on page 4-77.
Reported Error Codes Table 3–6 contains possible error codes. TABLE 3–6. Report Error Codes
3-32
Error Number
Error Description
0
"Decode Successful"
3048
"Unable to decode"
4601
"No edge candidate found"
4604
"First edge not found"
4605
"Second edge not found"
4611
"Third edge not found"
4612
"Fourth edge not found"
4620
"Four corners not found"
4621
"Size varying too much"
4622
"Row / Column test failed"
4630
"Inspection timeout"
4633
“Border match test failed”
4650
"Verification contrast calibration failure"
4651
"Verification cellunit calibration failure"
4700
"Verification process error"
4701
"Verification unsupported"
4702
"Verification timeout"
4710
"ISO Verification ECC200 required"
4711
"ISO Verification aperture too small"
4712
"ISO Verification aperture too large"
4713
"ISO Verification insufficient space"
4714
"ISO Verification failed RDA STEP F 1"
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 107
Formatted Output & Audio
TABLE 3–6. Report Error Codes (Continued)
v2.4.1, Nov 2008
Error Description
4715
"ISO Verification failed RDA STEP F 2"
4716
"ISO Verification failed RDA STEP F 3"
4717
"ISO Verification failed RDA STEP A E"
4718
"ISO Verification failed final image adjustment"
4719
"ISO Verification failed RDA error correction"
4720
"ISO Verification DM row/column too large"
4721
"ISO Verification cell smaller than Min x"
4722
"ISO Verification cell larger than Max x"
6001
"QR Code general error"
6002
"QR Code ratio error"
6003
"QR Code finder error"
6004
"QR Code line fit error"
6005
"QR Code line intersect error"
6006
"QR Code corner error"
6007
"QR Code boundary error"
6008
"QR Code length ratio error"
6020
"QR Code decode unknown error"
6021
"QR Code rs level invalid"
6022
"QR Code format info failed"
6023
"QR Code version info failed"
6024
"QR Code rows cols invalid"
6025
"QR Code data codewrd invalid"
6026
"QR Code total codeword invalid"
6027
"QR Code mode indicator invalid"
6028
"QR Code mode unimplemented"
6029
"QR Code rs decode failed"
6030
"QR Code BCH15 5 undecodable"
6031
"QR Code model invalid"
6032
"QR Code timeout error"
6100
"QR Code design unimplemented"
6101
“NO UID ENABLE”
HawkEye™ 1500 Series User Manual
3 HawkEye™ 1500 Series Overview
Error Number
3-33
Page 108
Chapter
3
HawkEye™ 1500 Series Overview
TABLE 3–6. Report Error Codes (Continued)
3-34
Error Number
Error Description
6102
“HEADER 1ST POSITION ERROR”
6103
“HEADER 2RD POSITION ERROR”
6104
“HEADER 3RD POSITION ERROR”
6105
“HEADER 4TH POSITION ERROR”
6106
“HEADER GS ERROR”
6107
“FORMAT INDICATOR ERROR”
6108
“TRAILER RS ERROR”
6109
“TRAILER EOT ERROR”
6110
“DOUBLE TRAILER ERROR”
6111
“DATA ELEMENT SEPARATOR ERROR”
6140
“SOFTWARE ERROR 1”
6190
“DATA QUALIFIER SPACE”
6192
“TEI DATA QUALIFIER”
6194
“TEI SPACE ERROR”
6195
“WRONG FORMAT INDICATOR”
6200
“DATA QUALIFIER ERROR”
6201
“NEED UII ELEMENT FIRST”
6202
“NO UII ELEMENT ERROR”
6203
“UII ELEMENT INCOMPLETE”
6204
“DATA ELEMENT CHARACTER”
6205
“LOWER CASE CHARACTER”
6206
“DATA ELEMENT TOO SHORT”
6207
“DATA ELEMENT TOO LONG”
6208
“ENTERPRISE NUM TOO LONG”
6209
“ORIGINAL PARTNUM TOO LONG”
6210
“SERIAL NUM TOO LONG ERROR”
6211
“REQUEST ELEMENT NUM ERROR”
6212
“UII TOO LONG”
6213
“SOFTWARE ERROR 2”
6301
"PNR TOO LONG"
6302
"PNR TOO SHORT"
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008
Page 109
QuicSet® Symbol Photometry
TABLE 3–6. Report Error Codes (Continued)
Error Description
6303
"PNR CHARACTER ERROR"
6311
"30P TOO LONG"
6312
"30P TOO SHORT"
6313
"30P CHARACTER ERROR"
6321
"240 TOO LONG"
6322
"240 TOO SHORT"
6323
"240 CHARACTER ERROR"
6331
"30T TOO LONG"
6332
"30T TOO SHORT"
6333
"30T CHARACTER ERROR"
6399
"NO CURRENT PART NUMBER"
3 HawkEye™ 1500 Series Overview
Error Number
QuicSet® Symbol Photometry When the HawkEye™ is set up in triggered mode, Auto Photometry may not be appropriate. When the Photometry values need to be known ahead of time because the time cannot be spent determining Gain and Exposure values, the QuicSet® Symbol Photometry function can be invoked to determine the correct Gain and Exposure to be used for the part. Perform one of the following procedures: Procedure 1 If the part to be read is aligned, then follow this procedure: 1.
Insert a paper clip into the hole marked QuicSet® and press once. Any time after hearing a beep, press the QuicSet button again to exit. The Photometry value (Gain and Exposure) have been determined.
OR Procedure 2 If the part to be read is not aligned, then follow this procedure: 1.
v2.4.1, Nov 2008
Insert a paper clip into the hole marked QuicSet® and press once.
HawkEye™ 1500 Series User Manual
3-35
Page 110
Chapter
3
HawkEye™ 1500 Series Overview
2.
Ensure that the yellow Mode light is flashing. Physically position the HawkEye™ 1500 until the laser dots are almost together for small Data Matrix symbols, or slightly farther apart on the horizontal axis for bar code symbols.
DO NOT LOOK AT THE LASER. WHEN READING PARTS THAT ARE HIGHLY REFLECTIVE, BE CAREFUL THAT THE LASER IS NOT REFLECTED INTO SOMEONE’S EYE.
When the laser beams are centered on the symbol, a series of beeps will be heard. The beeps have three tones:
–
Low, Signals that the symbol is in the field of view
–
Middle, Signals that the symbol is close to optimal read position
–
High, Signals the optimal position
The three LEDs above the blinking Mode LED correspond to the three beeps.
3.
–
With poor alignment, there are no LEDs flashing and there is no beeping.
–
As the alignment improves, the LEDs begin to illuminate, from bottom to top, and beeping begins.
–
At optimal alignment, all the LEDs are flashing and beeping is at its highest intensity.
Slightly move the HawkEye™ 1500 until the high intensity beep is achieved, lock down the camera’s position, then press the QuicSet® button once to exit QuicSet® mode. You will hear three short beeps and the Mode LED will return to steady on. This indicates that the HawkEye™ is ready to read using the QuicSet® mode settings.
4.
3-36
Insert a paper clip into the hole marked QuicSet® and press once. Any time after hearing a beep, press the QuicSet button again to exit. The Photometry value (Gain and Exposure) have been determined.
HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008