Page 91

HawkEye™ 1500 I/O Operations

Trigger Diagram 6 This example generates a trigger overrun condition because the delay is set so long that the maximum number of pending triggers is exceeded. Td > time for max triggers Tl < time between triggers Tacq > time between triggers

3

Trigger Diagram

HawkEye™ 1500 Series Overview

FIGURE 3–6.

Td Trigger

Tl t1 t2

........

t99 t100

Latch end t101

Acq start

Time

Triggering the Unit (Inputs) The HawkEye™ 1500 requires a trigger to activate scanning. There are two types of triggers that control the unit: physical (hardware) and virtual (software) triggers. The selection of which trigger will be used is highly coordinated with the Application Mode selection provided by ReadRunner. When you select Demo mode or Supermarket mode, the system is virtually triggering itself continuously; once an image is taken and handled, it virtually triggers itself to initiate another sequence as soon as it completes the previous sequence. Therefore, the HawkEye™ 1500 is continuously running and requires no physical triggers to operate. When you select Motion mode or Stop and Scan v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

3-17

Page 92

Chapter

3

HawkEye™ 1500 Series Overview mode, you are configuring the system such that a physical trigger event must occur to initiate the capture and decode sequence.

Physical Triggers The input lines allow you to add product sensors or user-defined sources to sense products marked with the Data Matrix symbol. A product passes through the sensor mounted in proximity of the monitored manufacturing line. Once the sensor’s path is broken, a trigger signal is sent to the HawkEye™ 1500 via the I/O connector. The HawkEye™ 1500 receives the signal and tells the camera to capture the upcoming image. Then, the image is decoded and data is sent to the RS-232/Ethernet ports. At the same time, the camera sends signals to the I/O connector as output signals for you. For more information, see “Outputs” on page 3-19. Typically, this trigger is an external device hardwired to the Opto Isolated pin provided on the HawkEye™ 1500 series connector. (See “Field I/O Connector” on page 2-8.) When the trigger input is received, the HawkEye™ 1500 will initiate the sequence. If the trigger input is received too fast, such that the HawkEye™ 1500 cannot keep up, the camera will issue a RTE (Real Time Error) condition. This condition is reported in several ways: one is via the user configurable RTE Error message string (see “Output Format Strings” on page 4-71), and via the digital output line that has been assigned to report the “RTE” state of the HawkEye™ 1500 connector (see “Field I/O Connector” on page 2-8), and also to ReadRunner through the internal reporting mechanism (see Chapter 4, “ReadRunner”).

Virtual Triggers When configuring the HawkEye™ 1500 with your external equipment, you can virtually trigger the unit to simulate the Opto Isolated input to further debug and set up. This can be accomplished by depressing the Trigger button provided on ReadRunner (see Chapter 4, “ReadRunner”), or by issuing the following command: ‘VT 2’ where 2 is the internal number associated with the Opto Isolated Trigger input.

Alternately, you could also have an external piece of equipment issue the VT command at the desired rate in lieu of using the physical trigger.

3-18

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 93

HawkEye™ 1500 I/O Operations

Additional Physical Triggers Available In addition to the Opto Isolated trigger provided on Pin pair 1, 11, you could also make use of the 4 TTL inputs to the camera. For more information, see “Field I/O Connector” on page 2-8, and “Advanced I/O” on page 4-54.

Outputs

The HawkEye™ 1500 camera’s I/O connector has the following I/O lines: •

Pin pair 2, 12 corresponds to Pass signal (default assignment)

•

Pin pair 3, 13 corresponds to Fail signal (default assignment)

•

Pin pair 4, 14 corresponds to Data Valid signal (default assignment)

The following four I/O Modes are available (shown with their default assignment lines): •

Pass/Fail Only - Full Handshake, Handshake mode with OPTO_OUT1 = Pass, OPTO_OUT2 = Fail.

•

Pass/Fail Only - Pipelined, PULSE/PIPELINED mode with OPTO_OUT1 = Pass, OPTO_OUT2 = Fail.

•

Data Valid - Full Handshake, Handshake mode with OPTO_OUT1 = Pass, OPTO_OUT2 = Fail, OPTO_OUT3 = Data Valid.

•

Data Valid - Pipelined, PULSE/PIPELINED mode with OPTO_OUT1 = Pass | Fail, OPTO_OUT3 = Data Valid.

In addition, with the Verification option, the following I/O modes are also supported:

v2.4.1, Nov 2008

•

DV - 2 Line Verify - Full HS, GOOD, FAIR, POOR multiplexed on two assigned lines plus Data Valid

•

DV - 3 Line Verify - Full HS, GOOD, FAIR, POOR, Data Valid, lines are assigned

HawkEye™ 1500 Series User Manual

3-19

3 HawkEye™ 1500 Series Overview

Once an image is decoded, the data is sent to the RS-232/Ethernet ports. At the same time, the HawkEye™ 1500 sends signals to the I/O connector. The camera can be configured in such a way as to communicate its Read results to an external device via these I/O lines.

Page 94

Chapter

3

HawkEye™ 1500 Series Overview

•

DV - 2 Line Verify - Pulse, GOOD, FAIR, POOR multiplexed on two assigned lines plus Data Valid

•

DV - 3 Line Verify - Pulse, GOOD, FAIR, POOR, Data Valid, lines are assigned

•

None – No external lines are driven to indicate any status

The mode selection can be made via ReadRunner IO Settings display or via serial command: IO_MODE {mode} {duration}

For specifics, type: HELP IO_MODE VERBOSE

In any of the I/O modes except None, the RTE signal may also be assigned. RTE signals a Real Time Error; in other words, Trigger Overrun on Pin #8 (default assignment on GPIO_OUT3). In all of the modes, you can configure the polarity of the lines by using the SIGOUT command. In the following description, the term “drive” will be assumed to be in the direction you define. In addition to the I/O lines being driven, the results are always presented on the camera status LEDs. If the Verification option is being used, the camera status LEDs translate to: •

GOOD = PASS LED

•

FAIR = PASS + FAIL LED

•

POOR = FAIL LED

Data Valid, Pipelined Note: The discussion of pin pairs assumes a default assignment of the I/O lines. The Data Valid - Pipelined Mode drives pin pair 2, 12 when the results of the Decode are a success. It drives the same line to the opposite direction when the results of the Decode are a failure. It then drives pin pair 4, 14 for the predetermined duration to indicate that the level on pin pair 2, 12 is valid. The line will be set to the polarity for an indicated duration. You can configure the duration of the signal by using the IO_MODE command.

3-20

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 95

HawkEye™ 1500 I/O Operations

SIGOUT used to have a delay that was not used by the code. It was left in as an option in the case of RTE to avoid rewriting all of the regression test. Also, SIGOUT applies to the line state and not the variable assigned to the line. FIGURE 3–7. Data Valid - Pipelined Mode

1

3

Trigger

HawkEye™ 1500 Series Overview

Acquire Decode assert negate time time

Present Pass/Fail DV Setup Time

2

3

4

Notes: 1.

User asserts Trigger (user can re-trigger after acquisition is complete).

2.

When read is complete, reader sets Pass/Fail and asserts DV after 2 ms set-up time.

3.

Reader negates DV after user programmed “signal duration” time (new decode can start).

4.

Reader can assert DV again only after an additional “signal duration time.”

Pass/Fail Only, Pipelined Note: The discussion of pin pairs assumes a default assignment of the I/O lines. The Pass/Fail Only - Pipelined Mode drives pin pair 2, 12 when the results of the Decode are a success and, at the same time, drives pin pair 3, 13 to the opposite v2.4.1, Nov 2008

HawkEye™ 1500 Series User Manual

3-21

Page 96

Chapter

3

HawkEye™ 1500 Series Overview direction. When the results of the Decode are a failure, it drives pin pair 3, 13 and, at the same time, drives pin pair 4, 14 to the opposite direction. The line will be set to the polarity for an indicated duration. You can configure the duration of the signal by using the IO_MODE command. Figure 3–8 depicts a Trigger occurring, which initiates an Image acquisition, which in turn is passed on to the Decoder for analysis. Once the outcome is determined, the Pass or Fail is presented on the I/O lines for the desired duration. FIGURE 3–8. Pass/Fail Only - Pipelined

1

Trigger Acquire Decode assert negate 4 time time

Present Pass Fail 2

3

Notes: 1.

User asserts Trigger (user can re-trigger after acquisition is complete).

2.

When read is complete, reader sets either Pass or Fail.

3.

Reader negates Pass or Fail after user programmed “signal duration” time (new decode can start).

4.

Reader can assert Pass or Fail again only after an additional “signal duration time.”

Data Valid, Full Handshake Note: The discussion of pin pairs assumes a default assignment of the I/O lines.

3-22

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 97

HawkEye™ 1500 I/O Operations

The Data Valid - Full Handshake Mode drives pin pair 2, 12 when the results of the Decode are a success. It drives the same line to the opposite direction when the results of the Decode are a failure. It then drives pin pair 4, 14 to indicate that pin pair 2, 12 is valid and represents pass or fail. The line will be set to the desired polarity and will stay at that polarity until the next trigger initiates a new acquisition. Figure 3–9 depicts a Trigger occurring, which initiates an Image acquisition, which in turn is passed on to the Decoder for analysis. Once the outcome is determined, the Pass or Fail is presented on the I/O line until the next trigger occurs.

3 HawkEye™ 1500 Series Overview

FIGURE 3–9. Data Valid - Full Handshake

3

1

Trigger Acquire Decode Present Pass/Fail DV Setup Time 4 2

Notes:

v2.4.1, Nov 2008

1.

When DV is false, you can start read by asserting TRIG.

2.

When read is completed, reader sets Pass/Fail and asserts DV after 2ms setup time.

3.

User accepts Pass/Fail result and then negates TRIG.

4.

Reader detects TRIG negated and then negates DV.

HawkEye™ 1500 Series User Manual

3-23

Page 98

Chapter

3

HawkEye™ 1500 Series Overview

Pass/Fail Only, Full Handshake Note: The discussion of pin pairs assumes a default assignment of the I/O lines. The Pass/Fail Only - Full Handshake Mode drives pin pair 2, 12 when the results of the Decode are a success and, at the same time, drives pin pair 3, 13 to the opposite direction. When the results of the Decode are a failure, it drives pin pair 3, 13 and, at the same time, drives pin pair 2, 12 to the opposite direction. The line will be set to the desired polarity and will stay at that polarity until the next trigger initiates a new acquisition. Figure 3–10 depicts a Trigger occurring, which initiates an Image acquisition, which in turn is passed on to the Decoder for analysis. Once the outcome is determined, the Pass or Fail is presented on the I/O lines until the next trigger occurs. FIGURE 3–10. Pass/Fail Only - Full Handshake

3

1

Trigger Acquire Decode Present Pass Fail

2

4

Notes:

3-24

1.

When both Pass and Fail are false, you can start read by asserting TRIG.

2.

When read is completed, reader sets either Pass or Fail.

3.

User accepts Pass/Fail result and then negates TRIG.

4.

Reader detects TRIG negated and then negates both Pass and Fail.

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008

Page 99

HawkEye™ 1500 I/O Operations

DV - 2 Line Verify, Full HS

FIGURE 3–11. DV - 2 Line Verify - Full HS

3

1

Trigger Acquire Decode Present Good Poor DV Setup Time 4 2

Notes:

v2.4.1, Nov 2008

1.

When DV is false, you can start read by asserting TRIG.

2.

When read is completed, reader sets the Good / Fair / Poor / Fail state and asserts DV after 2ms setup time.

3.

User accepts the Good / Fair / Poor / Fail result and then negates TRIG.

HawkEye™ 1500 Series User Manual

3 HawkEye™ 1500 Series Overview

The DV 2 Line Verify - Full HS Mode drives the Good and Poor lines when the results of the verification are completed (see Table 3–2 for the line states of Good, Fair, Poor, and Fail). This mode then drives the Data Valid line to indicate that the Good and Poor lines are valid and stable. The lines will be set to the desired polarity and will stay at that polarity until the next trigger initiates a new acquisition. Figure 3–11 depicts a Trigger occurring, which initiates an Image acquisition, which in turn is passed on to the Decoder for analysis. Once the outcome is determined, the Good, Fair, Poor, or Fail is presented on the I/O lines until the next trigger occurs.

3-25

Page 100

Chapter

3

HawkEye™ 1500 Series Overview

4.

Reader detects TRIG negated and then negates DV.

TABLE 3–2. Two Line Multiplex of Verification Results

Line Keyword Name State

Good

Poor

Good

On

On

Fair

On

Off

Poor

Off

On

Fail

Off

Off

DV - 3 Line Verify, Full HS The DV 3 Line Verify - Full HS Mode drives the Good, Fair, and Poor lines when the results of the verification are completed (see Table 3–3 for the line states of Good, Fair, Poor, and Fail). This mode then drives the Data Valid line to indicate that the Good, Fair, and Poor lines are valid and stable. The lines will be set to the desired polarity and will stay at that polarity until the next trigger initiates a new acquisition. Figure 3–12 depicts a Trigger occurring, which initiates an Image acquisition, which in turn is passed on to the Decoder for analysis. Once the outcome is determined, the Good, Fair, Poor, or Fail is presented on the I/O lines until the next trigger occurs.

3-26

HawkEye™ 1500 Series User Manual v2.4.1, Nov 2008