Page 121
OKDEC This command customizes the successful decode output of the HawkEye™ 1500.
Syntax OKDEC {cntrl} [""string""] [{Hdrcntrl} {Trlcntrl} {Beepcntrl}] Where: cntrl, Is the OKDEC message active (Y or N)? string, (1 - 39 characters); the string may include keyword substitution (in parentheses): –
ANGLE, This keyword reports the Data Matrix angle in degrees from 0° to 359°.
–
CHECKSUM, This keyword expands to the checksum of the characters in the appropriate Output Format String where the (CHECKSUM) keyword is inserted. The two character ASCII value representation of the Hexadecimal checksum (for example, 2E) is substituted in the Output string. The checksum is calculated as the Exclusive OR (XOR) of all the characters up to the (CHECKSUM) keyword, including the Header and the Trailer characters if (CHECKSUM) is placed at the end of the trailer string.
–
DATA, This keyword will be substituted with the actual decoded string. For example, if “4567321” were decoded, and the event were set as “OKDEC: This is the decoded data: (DATA)\0d\0a” then the one line of output would look like the following: This is the decoded data: 4567321
Rev 2.4.1, Nov 2008
–
DATAHEX, This keyword converts the decode data to a hex character string, similar to the previous “OUTPUT FORMAT HEX” functionality.
–
DETAILED, This keyword returns a detailed failure string.
–
PID#, This keyword returns the PID number of the PID that successfully decoded the symbol.
–
TIMESTAMP, This keyword will be substituted with the current date and time.
HawkEye 1500 Reference & Programmers Manual
1-107
1 Remote Commands Reference
OKDEC
Page 122
Chapter
1
Remote Commands Reference
–
VERI_1_IAQG, This keyword provides a DMx AutoID compatibility mode for the IAQG Verification I report.
–
VERI_DETAIL, This keyword will be substituted with very detailed AIM information: Overall Grade, Grade Contrast, Contrast, Grade axial nonuniformity, Axial nonuniformity, Grade of print growth, Print growth x, Print growth y, Grade of error correction, Num error bits UEC value.
–
VERI_FORMATTED, This keyword (typically placed in the OKDEC formatted string) puts out the verification data with the following format. OG:3 CG:3 C:65 nG:4 n:0.00 GPG:3 PGx:0.20 PGY:0.02 GUEC:4 #B:0 UEC:1.00
–
VERI_GRADE, This keyword will be substituted with the AIM grade. The string may also include non printable control characters by typing the backslash character followed by the two character hex number that represents the character. For example, \0d is a CR and \0A is a LF.
Note: The following parameters are optional. However, it you enter one of them, you must enter all of them at the same time. Hdrcntrl, Print the header before the OKDEC string (Y or N)? Trlcntrl, Print the trailer before the OKDEC string (Y or N)? Beepcntrl, Sound this many beeps (0 - 3) when this report is issued. The default is 0.
1-108
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 123
OKMATCH This command customizes the successful match output of the HawkEye™ 1500.
Syntax OKMATCH {cntrl} [""string""] [{Hdrcntrl} {Trlcntrl} {Beepcntrl}] Where: cntrl, Is the OKMATCH message active (Y or N)? string, (1 - 39 characters); the string may include keyword substitution: –
ANGLE, This keyword reports the Data Matrix angle in degrees from 0° to 359°.
–
CHECKSUM, This keyword expands to the checksum of the characters in the appropriate Output Format String where the (CHECKSUM) keyword is inserted. The two character ASCII value representation of the Hexadecimal checksum (for example, 2E) is substituted in the Output string. The checksum is calculated as the Exclusive OR (XOR) of all the characters up to the (CHECKSUM) keyword, including the Header and the Trailer characters if (CHECKSUM) is placed at the end of the trailer string.
–
DATA, This keyword will be substituted with the actual decoded string. For example, if “4567321” were decoded, and the event were set as “OKDEC: This is the decoded data: (DATA)\0d\0a” then the one line of output would look like the following: This is the decoded data: 4567321
Rev 2.4.1, Nov 2008
–
DATAHEX, This keyword converts the decode data to a hex character string, similar to the previous “OUTPUT FORMAT HEX” functionality.
–
DETAILED, This keyword returns a detailed failure string.
–
PID#, This keyword returns the PID number of the PID that successfully decoded the symbol.
–
TIMESTAMP, This keyword will be substituted with the current date and time.
HawkEye 1500 Reference & Programmers Manual
1-109
1 Remote Commands Reference
OKMATCH
Page 124
Chapter
1
Remote Commands Reference
–
VERI_1_IAQG, This keyword provides a DMx AutoID compatibility mode for the IAQG Verification I report.
–
VERI_DETAIL, This keyword will be substituted with very detailed AIM information: Overall Grade, Grade Contrast, Contrast, Grade axial nonuniformity, Axial nonuniformity, Grade of print growth, Print growth x, Print growth y, Grade of error correction, Num error bits UEC value.
–
VERI_FORMATTED, This keyword (typically placed in the OKDEC formatted string) puts out the verification data with the following format. OG:3 CG:3 C:65 nG:4 n:0.00 GPG:3 PGx:0.20 PGY:0.02 GUEC:4 #B:0 UEC:1.00
–
VERI_GRADE, This keyword will be substituted with the AIM grade. The string may also include non printable control characters by typing the backslash character followed by the two character hex number that represents the character. For example, \0d is a CR and \0A is a LF.
Note: The following parameters are optional. However, it you enter one of them, you must enter all of them at the same time. Hdrcntrl, Print the header before the OKMATCH string (Y or N)? Trlcntrl, Print the trailer before the OKMATCH string (Y or N)? Beepcntrl, Sound this many beeps (0 - 3) when this report is issued. The default is 0.
1-110
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 125
ONLINE This command puts the unit online performing the desired application. When returning to online mode, the unit will beep three times rapidly and the Mode light will return to solid yellow.
Syntax ON[LINE]
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-111
1 Remote Commands Reference
ONLINE
Page 126
Chapter
1
Remote Commands Reference
ORIENT This command sets the matrix orientation in read mode. Orientation is set automatically by Learn which works for Read if matrix orientation does not change more than ± 45°. Otherwise, use ORIENT AUTO. Note: All measurements are assumed to be rotated in a counter clockwise direction.
Syntax ORIENT {orientation | AUTO} Where: orientation, Is one of the following:
1-112
–
1 = 0°
–
2 = 90°
–
3 = 180°
–
4 = 270°
–
5 = 45°
–
6 = 135°
–
7 = 225°
–
8 = 315°
–
AUTO, Autoselect (default)
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 127
OUTPUT •
To set up the different output states on the different ports: OUTPUT {PORT} {STATE} {FORMAT STRING} {ACTIVE} {H/T CONTROL}
•
To set up the header/trailer strings for the different ports: OUTPUT {PORT} H_T {FORMAT STRING} (FORMAT STRING}
Where: –
–
Rev 2.4.1, Nov 2008
PORT, Is one of the following: •
STANDARD (Camera’s serial port)
•
TCP1
•
TCP2
•
TCP3
•
TCP4
STATE, Is one of the following: •
OKDEC (see page 1–107)
•
DECFL (see page 1–49)
•
LOCFL (see page 1–87)
•
OKMATCH (see page 1–109)
•
MATCHFL (see page 1–97)
•
RTE (see page 1–155)
–
FORMAT STRING, Is the format string in quotes, or without quotes, if no spaces are needed
–
ACTIVE, For whatever you want to use, sets STATE on or off for the particular PORT, and is one of the following: •
Y or ON or ENABLE
•
N or OFF or DISABLE
HawkEye 1500 Reference & Programmers Manual
1-113
1 Remote Commands Reference
OUTPUT
Page 128
Chapter
1
Remote Commands Reference
–
•
H/T CONTROL, Activates the header and/or trailer, and is one of the following: •
NONE
•
H, Header
•
T, Trailer
•
H_T, Both header and trailer
To configure the different BEEP settings: OUTPUT BEEP {OKDEC} {DECFL} {LOCFL} {OKMATCH} {NOMATCH} {RTE} Each setting indicates the number of beeps to use on each possible output (0 | 1 | 2).
The original OKDEC, DECFL, RTE et al., commands set up the STANDARD and TCP1 settings only, and the beeps.
1-114
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov
Page 129
PARTQ This command enables/disables the part queue mechanism. The part queue stores a number of cycle reports in-line with the running inspection. The records are stored as a re-usable queue, that is, when the queue is full, the newest record replaces the oldest record. The part queue is loss-less.
Syntax PARTQ {opt} [qualifier] [size] Where: opt, Is one of the following: –
Y, Enable the part queue
–
N, Disable the part queue
–
R, Save reports without saving images qualifier, Specifies what you want to store. –
All, Store all records
–
Passed, Store records of passed inspections
–
Failed, Store records of failed inspections size, The number of records to store: Range: 1 - 100000
Rev 2.4.1, Nov 2008
HawkEye 1500 Reference & Programmers Manual
1-115
1 Remote Commands Reference
PARTQ
Page 130
Chapter
1
Remote Commands Reference
PARTQCAPACITY This command obtains the maximum record count based on free memory in the camera for records with images and records without images in the PartQ configuration.
Syntax PARTQCAPACITY {First value} {Second value} Where: •
First value, Maximum number of records with images
•
Second value, Maximum number of records without images
For example: PARTQCAPACITY 31 5700
1-116
HawkEye 1500 Reference & Programmers Manual
Rev 2.4.1, Nov