Page 111

MATCHFL This command customizes the unsuccessful match (nomatch) output of the HawkEye™ 1500.

Syntax MATCHFL {cntrl} [""string""] [{Hdrcntrl} {Trlcntrl} {Beepcntrl}] Where: cntrl, Is the MATCHFL message active (Y or N)? string, (1 - 39 characters); the string may include keyword substitution: –

ANGLE, This keyword reports the Data Matrix angle in degrees from 0° to 359°.

–

CHECKSUM, This keyword expands to the checksum of the characters in the appropriate Output Format String where the (CHECKSUM) keyword is inserted. The two character ASCII value representation of the Hexadecimal checksum (for example, 2E) is substituted in the Output string. The checksum is calculated as the Exclusive OR (XOR) of all the characters up to the (CHECKSUM) keyword, including the Header and the Trailer characters if (CHECKSUM) is placed at the end of the trailer string.

–

DATA, This keyword will be substituted with the actual decoded string. For example, if “4567321” were decoded, and the event were set as “OKDEC: This is the decoded data: (DATA)\0d\0a” then the one line of output would look like the following: This is the decoded data: 4567321

Rev 2.4.1, Nov 2008

–

DATAHEX, This keyword converts the decode data to a hex character string, similar to the previous “OUTPUT FORMAT HEX” functionality.

–

DETAILED, This keyword returns a detailed failure string.

–

PID#, This keyword returns the PID number of the PID that successfully decoded the symbol.

–

TIMESTAMP, This keyword will be substituted with the current date and time.

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

MATCHFL

1-97

Page 112

Chapter

1

Remote Commands Reference

–

VERI_1_IAQG, This keyword provides a DMx AutoID compatibility mode for the IAQG Verification I report.

–

VERI_DETAIL, This keyword will be substituted with very detailed AIM information: Overall Grade, Grade Contrast, Contrast, Grade axial nonuniformity, Axial nonuniformity, Grade of print growth, Print growth x, Print growth y, Grade of error correction, Num error bits UEC value.

–

VERI_FORMATTED, This keyword (typically placed in the OKDEC formatted string) puts out the verification data with the following format: OG:3 CG:3 C:65 nG:4 n:0.00 GPG:3 PGx:0.20 PGY:0.02 GUEC:4 #B:0 UEC:1.00

–

VERI_GRADE, This keyword will be substituted with the AIM grade. The string may also include non printable control characters by typing the backslash character followed by the two character hex number that represents the character. For example, \0d is a CR and \0A is a LF.

Note: The following parameters are optional. However, it you enter one of them, you must enter all of them at the same time. Hdrcntrl, Print the header before the MATCHFL string (Y or N)? Trlcntrl, Print the trailer before the MATCHFL string (Y or N)? Beepcntrl, Sound this many beeps (0 - 3) when this report is issued. The default is 2.

1-98

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 113

MATCHSERIAL This command specifies serial checking parameters. See the following related commands: •

“MATCHCOUNT” on page 1-94.

•

“MATCHEX” on page 1-95

•

“MATCHSTRING” on page 1-100.

Syntax MATCHSERIAL {incr} {1st char} {last char} Where: incr, The increment value to be added after each inspection. Range: -1000 thru +1000 1st char, The first character of the serial number to compare. Range: 1 - 1000 last char, The last character in the serial number to compare. Range: 1st char - 1000

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

MATCHSERIAL

1-99

Page 114

Chapter

1

Remote Commands Reference

MATCHSTRING This command sets match control to character matching. In simple applications, where the line is set up to compare the code read to a fixed string, you would use MATCH T (“string”). In other words, every part read must be the same. You would have different triggers assigned to different PIDs such that there is a different string to compare, depending on the trigger. See the following related commands: •

“MATCHCOUNT” on page 1-94.

•

“MATCHEX” on page 1-95

•

“MATCHSTRING” on page 1-100.

Syntax MATCHSTRING {string} Where: string, Is a string, which may include wildcards: ?, Single don’t care *, Multiple don’t cares Range: 1 - 80 upper and/or lowercase letters Default: Null String may include non-printable control characters in the following format: \0d = CR \0A = LF

1-100

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 115

MORPHOLOGY This command sets the morphological pre-processing of the image.

Syntax MORPH[OLOGY] {opt} [num] Where: opt, Is one of the following: –

ADAPTIVE, Hand-Held Demo mode where it tries no image processing first; if it fails, it tries Erode, if it fails, it tries Dilate.

–

CLOSE, DILATE and then ERODE (remove minor dark defects of light cells)

–

DILATE, Dilate light pixels and erode dark pixels

–

ERODE, Erode light pixels and dilate dark pixels (increase dark cell size and reduce light cell size)

–

NONE (default)

–

OPEN, ERODE and then DILATE (remove minor light defects of dark cells)

num, Is the number of passes: Range: 1 - 5 Default: 1

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

MORPHOLOGY

1-101

Page 116

Chapter

1

Remote Commands Reference

NEGATIVE This command enables/disables conversion of the camera acquired image to a negative image during the image acquisition phase.

Syntax NEGATIVE {ON | OFF} Where: ON, Enable OFF, Disable (default)

1-102

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 117

NO_QUIET_ZONE_CLUTTER See “FINETUNE” on page 1-66.

Rev 2.4.1, Nov 2008

HawkEye 1500 Reference & Programmers Manual

1 Remote Commands Reference

NO_QUIET_ZONE_CLUTTER

1-103

Page 118

Chapter

1

Remote Commands Reference

NUMBC This command sets the number of barcodes in a field of view to decode. To look for Data Matrix only, use NUMBC 0.

Syntax NUMBC {n} Where: n, Is the number of barcodes to decode: Range: 0 - 1 Default: 1

1-104

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov

Page 119

NUMDM This command specifies the maximum number of Data Matrix symbols to find. To look for 1-D only, use NUMDM 0.

Syntax NUMDM {n} Where: n, Is the maximum number of Data Matrix symbols to find:

Rev 2.4.1, Nov 2008

–

0, Disable/No look

–

1 (default)

HawkEye 1500 Reference & Programmers Manual

1-105

1 Remote Commands Reference

NUMDM

Page 120

Chapter

1

Remote Commands Reference

OFFLINE This command returns the unit to offline so that you can program it.

Syntax OFF[LINE]

1-106

HawkEye 1500 Reference & Programmers Manual

Rev 2.4.1, Nov