Page 71
Read Cycle
Active Camera Usage:
External and Dual options are useful where in applications where the reader cannot be located near the symbol or where both the internal and external cameras are required for products such as circuit boards that might have two symbols in different locations.
Definition:
The Quadrus EZ has its own internal camera complete with illumination and led sensor circuitry for capturing static or moving symbols at various camera settings including shutter, contrast, etc. The Quadrus EZ can also accept images from a remote (external) camera using the RS-170 communications protocol.
Serial Cmd:
<K240,active camera>
Default:
Internal
Options:
0 = Internal Camera 1 = External Camera 2 = Dual Camera
Important: The Quadrus EZ does not control the timing of external cameras. Captures from external cameras are streamed into the Quadrus EZ. To be sure to receive a complete first capture, allow an extra 33mS delay before the first external capture.
Quadrus EZ Reader User’s Manual
3-17
Page 72
Capture Mode
Capture Mode Definition:
Capture Mode relates to the way that multiple captures are processed by the Quadrus EZ.
Serial Cmd:
<K241,capture mode,number of captures,rapid capture mode>
Default:
Rapid Capture
Options:
0 = Rapid Capture
1 = Continuous Capture
Number of Captures Usage:
Used to increase the opportunities for good reads and to “extend” the field of view in dynamic applications.
Definition:
Sets the total number of captures that are processed during a read cycle in the Rapid Capture mode when Switching Mode is set to Number of Captures.
Serial Cmd:
<K241,capture mode,number of captures,rapid capture mode>
Default:
8
Options: 0 to 8 Note: When processing in Rapid Capture mode and Dual Capture mode, the number of captures set for each camera will be limited by the number of captures set here. For example, if Number Of Captures is set to 4, and the individual camera captures are set for 2 and 3 respectively, the last capture will be omitted.
Rapid Capture Mode Usage:
Rapid Capture is useful in fast moving applications in which symbols are only in the field of view a short time or precise timing between captures is relevant or when dual camera mode is enabled. A single capture with Last Frame ending the read cycle is the same as “single shot.”
Definition:
In Rapid Capture, decoding occurs independent of and simultaneous with capturing, thus allowing precise timing (Diagram B) or no delay (Diagram A) at all between captures. The downside is that the number of captures is limited to 8 so that processing buffers are not overloaded.
Serial Cmd:
<K241,capture mode,number of captures,rapid capture mode>
Default:
Timed Capture
Options:
0 = Timed Capture
3-18
1 = Triggered Capture
Quadrus EZ Reader User’s Manual
Page 73
Read Cycle
Timed Capture Usage:
Timed Rapid Capture is useful in fast moving applications in which symbols are only in the field of view a short time and precise timing is required.
Definition:
In Timed Rapid Capture, decoding occurs independent of and simultaneous with capturing, thus allowing precise timing (Diagram B) or no delay (Diagram A) at all between captures. Also, consecutive captures are regarded as the same symbol if the output data is the same. No Time Delay Between Captures
Start of Read Cycle
Diagram A n
End of read cycle
Time Before First Capture Time Delay Between Captures End of read cycle
Diagram B Processing
Rapid Capture Mode, Single Camera
Quadrus EZ Reader User’s Manual
3-19
Page 74
Capture Mode
Calculating Number of Captures in a Rapid Capture Application 1. First calculate the distance between multiple captures. For multiple captures in Rapid Capture mode, you can calculate the distance between successive symbols by multiplying the line speed by the capture time.
Distance traveled between captures
For CCD: TRAVEL DISTANCE = Line Speed X 15mS
For CMOS: TRAVEL DISTANCE = Line Speed X 30mS Capture time is a fixed “overhead” that includes the time of capture and transfer of the image. Note: For Dual Camera operations, add 33 mS to the overhead time for the first external capture. Example: A symbol moving at 10 ips (inches per second) past a CCD reader travels 0.010”/mS * 15 mS = 0.15 inches between captures. 2. Next calculate number of captures. 0.78 inches FOV
Once the travel time is known, you can easily calculate the number of captures you can expect to occur inside a FOV by subtracting the symbol size from the FOV and dividing the result by the travel time. NUMBER OF CAPTURES = (FOV–Symbol Size)/Travel Distance Following up on the example from Step 1:
0.4 inches Symbol Size
0.78" – 0.4"/0.15" = 2.5 captures If a required number of captures has been determined, you can also work the formula backwards and determine the minimum FOV by: FOV = (Number Of Captures * Travel Time) + Symbol Size
3-20
Quadrus EZ Reader User’s Manual
Page 75
Read Cycle
Triggered Capture Usage:
Useful in applications where delays between captures can be controlled by triggers rather than preset time delays.
Definition:
When enabled the reader will stay in the read cycle until either the userdefined number of captures has been met or, if configured, a timeout occurs.
Notes on Triggered Capture Mode: 1. Trigger Mode <K200> must be set to Edge, Serial, or Serial & Edge. If set to Level, Triggered Capture Mode will operate the same as Timed Rapid Capture mode. 2. For End of Read Cycle settings <K220>: a) If set to Timeout or New Trigger & Timeout and a timeout occurs before number of capture have been met, it will abort the read cycle and disregard the remaining number of triggers. b) If set to New Trigger, the reader remains in the read cycle until the number of captures is satisfied and an additional trigger is received indicating both the end of the read cycle and the start and first capture of the next read cycle. First trigger starts the read cycle
Captures on every trigger
Capture Read cycle ends on New Trigger or Timeout, as configured.
Processing
Triggered Captures, Typical
Quadrus EZ Reader User’s Manual
3-21
Page 76
Capture Mode
Continuous Capture Usage:
Continuous Capture is useful in applications with slower line speeds or where symbol spacing may be random or not time-dependent.
Definition:
In Continuous Capture a capture is followed sequentially by processing as shown above. Since processing is completed before another capture can occur (this usually takes about 30mS), a large number of captures can take place throughout a read cycle. Capture Start of Read Cycle
End of read cycle
Processing time
Continuous Capture
3-22
Quadrus EZ Reader User’s Manual
Page 77
Read Cycle
Capture Timing Note: Capture Timing applies only to Rapid Capture mode.
Time Before 1st Capture Usage:
In almost any moving line application, a time delay is needed to ensure that a symbol will be in the reader’s field of view at the beginning of the capture sequence.
Definition:
Time Before 1st Capture in a moving line application is the time between an external trigger event and the occurrence of the first capture.
Serial Cmd:
<K242,time before 1st capture,time between capture 1 and 2,,,,,,,,time between capture 7 and 8>
Default:
0
Options:
0 to 65535 (2.097seconds, in 32µS increments)
Start of read cycle Time Before First Capture
Processing
Time Before First Capture
Quadrus EZ Reader User’s Manual
3-23
Page 78
Capture Timing
Time Between Captures Usage:
This is useful in applications where more than one symbol can appear during a single read cycle (multisymbol), or where line speeds are slow enough that captured frames might overlap or miss a symbol.
Definition:
A time delay can be inserted between individual frame captures in the Rapid Capture mode.
Serial Cmd:
<K242,time before 1st capture,time between captures [time1,time2,...time7]> Entering 0’s will result in no time between captures (Diagram A). Entering a different value in each field will vary the time delays accordingly. (Diagram B) Note: You must enter time values along with comma separators for each field you want to change. If you omit fields, or enter only commas, the fields will remain as previously set.
Default:
0
Options:
0 to 65535 (2.097seconds, in 32µS increments)
Note: Number of Captures and number of delays (Time Between Captures) must be the same. Start of Read Cycle
Diagram A
Time Delay Between Captures = 0 1 2 3 4 5
End of read cycle
Time Delay Between Captures varies.
Diagram B
Time Delay Between Captures
3-24
Quadrus EZ Reader User’s Manual
Page 79
Read Cycle
Dual Camera Switching Note: The following options are only available when Active Camera is set to Dual. Usage:
Useful where different symbols can appear within a single read cycle.
Definition:
When Active Camera is set to Dual, captures will alternate between the internal and external cameras, starting with the internal camera.
Important Note: The Quadrus EZ does not control the timing of external cameras. Captures from external cameras are streamed into the Quadrus EZ. To be sure to receive a complete first capture, allow up to 33mS delay before the first external capture.
Switching Mode When Switching Mode is set to Number of Captures, the combined internal and external camera captures can not exceed the total number set in Number of Captures; however if the combined total is less than the total, then the capture pattern will be repeated until the total number of captures has been met. Definition:
Captures can be set to alternate between the internal and external cameras by the number of captures or by camera timeouts.
Serial Cmd:
<K243,switching mode,number of internal captures,number of external captures,internal camera timeout,external camera timeout>
Default:
Number of Captures
Options:
0 = Number Of Captures 1 = Timeout
Switching by Number of Captures Number of Internal Camera Captures Definition:
The number of captures taken by the internal camera before switching to the external camera.
Serial Cmd:
<K243,switching mode,number of internal captures,number of external captures,internal camera timeout,external camera timeout>
Default:
1
Options:
1 to 8
Quadrus EZ Reader User’s Manual
3-25
Page 80
Dual Camera Switching
Number of External Camera Captures Usage:
Useful where two cameras can expect different symbols within a given read cycle.
Definition:
The number of captures taken by the external camera before switching to the external camera.
Serial Cmd:
<K243,switching mode,number of internal captures,number of external captures,internal camera timeout,external camera timeout>
Default:
1
Options:
1 to 8
Rapid Capture Mode Examples Since examples 1 and 2 are in Rapid Capture mode, the cameras will continue to switch until the Number Of Captures setting has been met. Example # 1 Time Between Captures = 0, Active camera: Dual Capture mode: Rapid, Number of captures = 7 Number of internal camera captures = 5 Number of external camera captures = 3 Internal External Processing
1
2
3
4
Up to 33mS time delay before 1st external capture.
5 6
7
Note: The third capture for the external camera does not occur because the total number of captures (7) has been met. Note: In this mode, the first capture from an external camera (#6 is the above example) could be delayed for up to 33mS until the external camera synchronizes with the reader.
Example # 2 Time Between Captures = 0, Active Camera: Dual Capture Mode: Rapid, Number of captures = 8 Number of internal camera captures = 2 Number of external camera captures = 3 Extra 33mS time delay before 1st external capture.
Internal External Processing
1
2
6 3
4
5
7 8
Note: Since the total number of captures is greater than the combined number of captures of both cameras, capture source will oscillate between the two cameras until the total number (8) has been met.
3-26