Page 51
Communications
Postamble Postamble Status Usage:
Useful for identifying and controlling incoming data. For example, defining the postamble as a carriage return and a line feed causes each decoded message to be displayed of on its own line.
Definition:
Allows the user to enable or disable up to four postamble character(s) that can be added to the end of the decoded data.
Serial Cmd:
<K142,status,postamble character(s)>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled (within any protocol)
Postamble Character(s) Serial Cmd:
<K142,status,postamble character(s)>
Default:
^M^J. Corresponds to carriage return/line feed/null/null, as displayed in the menu. Up to four user-defined ASCII character, including control characters.
Within a Serial Command To enter control characters within a serial command, hold down the control key while typing the desired character. Example: <K142,1,CNTL-m CNTL-j> to enter ^M^J. Options:
Within an Embedded Menu Control characters entered on the command line are displayed in the menu as mnemonic characters, such as: <CR><LF><NUL><NUL> To enter a control character from within an embedded menu, first type in a space (with the space key). This has the effect of allowing the control key to be recognized as a part of the control character. Next hold down the control key while typing the desired character. Example: Space CNTL-m Space CNTL-j to enter ^M^J.
Quadrus EZ Reader User’s Manual
2-25
Page 52
Response Timeout
Response Timeout Usage:
Only used when a response is required from the host. While in Multidrop, if the reader does not receive an ACK or NAK from the host after sending polled data, it will act on a fault. The reader can be set to wait indefinitely by setting Response Timeout to zero.
Definition:
Time the reader will wait before timing out if ACK, NAK, and ETX are enabled, and a host response is expected.
Serial Cmd:
<K143,response timeout>
Default:
2 (in 10mS increments = 20mS)
Options:
0 to 255 (A zero (0) setting causes an indefinite wait.)
2-26
Quadrus EZ Reader User’s Manual
Page 53
Communications
LRC Status (Longitudinal Redundancy Check) Usage:
Used when extra data integrity is required.
Definition:
An error-checking routine that verifies the accuracy of transmissions. It is the exclusive OR of all characters following the STX (start of text) up to and including the ETX (end of text). What this means is that the binary representation of all the characters in a transmissions are cumulatively added in a column and each resulting odd integer is assigned a 1 and each even integer a 0 (two 1s = 0, two 0s = 0, a 1 and a 0 = 1). The extra LRC character is then appended to the transmission and the receiver (usually the host) performs the same addition and compares the results.
Serial Cmd:
<K145,status>
Default:
Disabled
Options:
0 = Disabled
Quadrus EZ Reader User’s Manual
1 = Enabled
2-27
Page 54
Aux Port System Data Status
Aux Port System Data Status Definition:
When enabled, directs data from the reader to the auxiliary port.
Serial Cmd:
<K146,aux port system data>
Default:
Disabled
Options:
0 = Disabled
2-28
1 = Enabled
Quadrus EZ Reader User’s Manual
Page 55
3 Read Cycle Contents Read Cycle by ESP ...................................................................................................................... 3-2 Read Cycle Serial Commands ..................................................................................................... 3-3 Read Cycle Setup......................................................................................................................... 3-4 Multisymbol................................................................................................................................... 3-5 Trigger .......................................................................................................................................... 3-7 Serial Trigger .............................................................................................................................. 3-13 End of Read Cycle...................................................................................................................... 3-15 Active Camera ............................................................................................................................ 3-17 Capture Mode............................................................................................................................. 3-18 Capture Timing ........................................................................................................................... 3-23 Dual Camera Switching .............................................................................................................. 3-25 Store Noread Image ................................................................................................................... 3-30
After you’ve established communications and completed basic read rate testing, you will need to address the spatial and timing parameters associated with your application. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
Quadrus EZ Reader User’s Manual
3-1
Page 56
Read Cycle by ESP
Read Cycle by ESP
Click this button to bring up the Read Cycle menu. To open nested options, single-click the +.
To change a setting, double-click the setting and use your cursor to scroll through the options.
3-2
Quadrus EZ Reader User’s Manual
Page 57
Read Cycle
Read Cycle Serial Commands Multisymbol Trigger Mode/Duration External Trigger State Serial Trigger Character Start Trigger Character Stop Trigger Character End of Read Cycle Active Camera
<K222,number of symbols,multisymbol separator> <K200,trigger mode,trigger filter duration> <K202,extermal trigger state> <K201,serial trigger character> <K229,start character> <K230,stop character> <K220,end of read cycle,read cycle timeout> <K240,active camera> <K241,capture mode,number of captures,rapid capture Captures mode> <K242,time before 1st capture,time between capture 1 and 2 Capture Timing ,,,,,,,,time between capture 7 and 8> <K243,switching mode,number of internal camera captures, Dual Camera Operations number of external camera captures,internal camera timeout, external camera timeout> Store Noread Image <K244,image storage type,image storage mode>
Quadrus EZ Reader User’s Manual
3-3
Page 58
Read Cycle Setup
Read Cycle Setup Based on your application, setting up read cycle and triggering parameters will involve a series of decisions, as follows: 1. Select the number of symbols to be read in a read cycle (must not exceed Number Of Captures). 2. Decide the trigger type to be used: if serial, the serial character; if external, Level or Edge. 3. Designate how the read cycle should end (Timeout, New Trigger, Last Frame) 4. Calculate the maximum and minimum field of view (FOV). 5. Consider the speed of the transport in inches per second 6. Select Capture mode, Continuous or Rapid. 7. Select Number Of Captures. 8. Set the Time Before First Capture and Time Between Captures, if any. 9. If using an external camera, select the active camera(s). 10. Decide if you need to alternate between cameras, with Switching Mode. 11. Save settings to the IP database. Note: With a CCD sensor, images can be captured at a rate of 60/second. In CMOS, capture rate is 30/second.
3-4
Quadrus EZ Reader User’s Manual
Page 59
Read Cycle
Multisymbol Usage:
Multisymbol is commonly used in shipping applications where a shipping symbol contains individual symbols for part number, quantity, etc. This feature allows one trigger to pick up all the symbols.
Definition:
Multisymbol allows the user to define up to 6 symbols that can be read in a single read cycle. The following conditions apply: 1. Each symbol must be different to be read. 2. The maximum number of characters in a read cycle is 32,520 for all symbols. 3. The maximum number of characters the reader can transmit is calculated by: Preamble + maximum number of symbols * (aux id + symbology id + maximum symbol length + ((number of insertion cells x cell length)+ separator) + postamble + LRC = 37,425.
Conditions:
4. All noread messages are posted at the end of the data string. 5. If more than one symbol is within the field of view at the same time, symbol data may not be displayed in the order of appearance. 6. If Matchcode Type is set to Sequential or if Trigger is set to Continuous Read 1 Output, Number of Symbols will default to 1 (if set to any number greater than 1).
Number of Symbols Definition:
Number of Symbols is the number of different symbols that can be read in a single read cycle.
Serial Cmd:
<K222,number of symbols,multisymbol separator>
Default:
1
Options:
1 to 6
Quadrus EZ Reader User’s Manual
3-5
Page 60
Multisymbol
Multisymbol Separator Usage:
Used to delimit or separate data fields with a user defined character.
Definition:
Any valid ASCII character, inserted between each symbol read when Multisymbol is set to any number greater than 1.
Serial Cmd:
<K222,number of symbols,multisymbol separator> Note: If Multisymbol Separator has been changed to any other character than the default comma and you wish to re-define the separator as a comma, use ESP or the embedded menus.
Default:
, (comma)
Options: Any available ASCII character, except < or > (if used as delimiters). Note: If a NULL is entered for the multisymbol separator, the multisymbol separator output will be disabled. Note: If noread messages are disabled and there are noreads occurring, separators will only be inserted between symbol data outputs.
3-6
Quadrus EZ Reader User’s Manual