The text of a manual · part 24 of 37
Quadrus EZ Reader User's Manual, pages 231 to 240
Pages 231 to 240 of 366
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Microscan EZ 6700 EX
Page 231
Camera Setup
Other Camera Parameters The following commands are listed in other menus but included in the Camera menu as a convenience:
For:
See Chapter 4, Symbologies.
For:
See Chapter 4, Symbologies.
For:
See Chapter 3, Read Cycle.
Quadrus EZ Reader User’s Manual
9-23
Page 232
Other Camera Parameters
9-24
Quadrus EZ Reader User’s Manual
Page 233
10 IP Database Contents IP Database by ESP................................................................................................................... 10-2 IP Database Serial Commands .................................................................................................. 10-3 Overview of IP Database............................................................................................................ 10-4 Operation of IP Database ........................................................................................................... 10-4 IP Database Window .................................................................................................................. 10-6 Number of Active Database Settings.......................................................................................... 10-7 CCD Image Sensor Database .................................................................................................... 10-8 CMOS Image Sensor ............................................................................................................... 10-10 Save Current Settings to Database .......................................................................................... 10-13 Load Current Settings from Database ...................................................................................... 10-13 Request Database Settings...................................................................................................... 10-14 Request All Database Settings................................................................................................. 10-14
An image processing database allows the user to save up to 10 multiple camera/image processing settings. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
Quadrus EZ Reader User’s Manual
10-1
Page 234
IP Database by ESP
IP Database by ESP
Click this button to bring up the Read Cycle/ Triggering menu.
10-2
You will see these tabs to the left of the Camera Settings tree control. Click on the IP Database tab.
Quadrus EZ Reader User’s Manual
Page 235
IP Database
IP Database Serial Commands IP Database Size CCD Database
CMOS Database Save Current Settings to Database - CCD Save Current Settings to Database - CMOS Load Current Settings to Database - CCD Request Database Settings - CCD Request Database Settings - CMOS Request all Database Settings - CCD Load Current Settings to Database - CMOS Request all Database Settings - CMOS
Quadrus EZ Reader User’s Manual
<K252,number of active database settings> <K250,CCD database index,shutter speed,gain,threshold mode, fixed threshold value,processing mode,background color,narrow margins> <K251,CMOS database index,shutter speed,gain,contrast,offset,threshold mode,fixed threshold value,processing mode,background color,narrow margins> <K250+,database index> <K251+,database index> <K250-,database index> <K250?,database index > <K251?,database index > <K250?> <K251-,database index> <K251?>
10-3
Page 236
Overview of IP Database
Overview of IP Database Usage:
Useful in applications in which a variety of symbol conditions require different settings that can be applied in real time.
Definition:
Up to 10 multiple camera/image processing settings can be saved to a database and be applied sequentially during operations.
Operation of IP Database Once IP Database is enabled, the reader’s current settings for Shutter Speed, Gain, Threshold Mode, Fixed Threshold Value, Processing Mode, Background Color, and Narrow Margins will no longer impact reader operation. For those parameters, only settings that are in the database will be used for image capture and processing. When in IP Database mode and at the end of a read cycle or a calibration routine, if a decode has occurred, the settings that were applied to that decode will move to the top of the database. For example if a decode occurred using the 4th configuration index, it would be moved to index #1 and the configurations preceding index 4 would be moved down one slot as illustrated below: Index 1 2 3 4 5
Moved to 2 3 4 1 5
When changing database settings, it is not always necessary to re-capture an image. If the new configuration changes a camera parameter, then it is necessary to re-capture an image. The capture mode selected (Rapid or Continuous) also has an impact on whether a new image needs to be captured. The following summarizes the operation of the reader for the two different capture modes when the IP database is enabled.
10-4
Quadrus EZ Reader User’s Manual
Page 237
IP Database
Rapid Capture Mode In Rapid Capture mode, a capture can occur during image processing. For this reason it is not possible to modify any image processing or decode parameters in this mode and only camera configuration settings in the database will take effect. The following IP database settings are not applied while in Rapid Capture mode: Threshold mode, Fixed Threshold Value, Processing Mode, Background Color and Narrow Margins. In Rapid Capture mode, when a reader enters the read cycle, it uses index 0 settings of the IP database for the 1st image capture. For each successive capture the IP database index is incremented and the new settings are applied to the new capture. A new capture is acquired for each database configuration. When the last active database index is filled and there are more captures to take, the index will start back at 0.
Continuous Capture Mode When IP database is enabled (whenever Database Size is not equal to 0), Continuous Capture no longer works in a double-buffered format. When the read cycle begins, the reader enters uses index 0 settings of the IP database for the 1st image capture. The reader will capture and decode the image, and increment the database index and apply the new configuration. If the new configuration does not change camera settings, then a new image is not acquired and the reader will try to decode the current captured image with the new image processing settings. If the camera settings have changed from the previous settings, then a new capture is required. When the end of the active database configuration has been reached, the index will start back at 0.
Quadrus EZ Reader User’s Manual
10-5
Page 238
IP Database Window
IP Database Window In ESP when you click on the IP Database tab you will see the following:
Changes to settings in the Current row will be reflected in ESP settings
Click once to select the index row; Double-click on any cell to make specific changes Setting to any number other than zero will enable (same as <K252>) Copies saved db settings to the window Saves selected index settings to db.
Copies the selected index settings to Current index
Starts a calibration routine
From ESP, you enable IP Database by setting Number of Active Database Settings to any number other than zero, the number chosen will cause the same number of rows in the database above to turn blue. You can make changes to any setting in any row simply by double-clicking and changing the resulting popup dialog. You can change current settings in ESP by making changes in the Current row of the database or by making changes in the tree commands to the left of the database.
10-6
Quadrus EZ Reader User’s Manual
Page 239
IP Database
Number of Active Database Settings Usage:
It’s important to remember that IP Database Size must be set for the number of indices you are planning to define for your database.
Definition:
This determines the number of active database indices. Whenever the number of active database indices is something other than 0, IP database is enabled. In the IP Database tab, enter the number of database settings.
ESP:
Serial Cmd:
<K252,number of active database settings>
Default:
0
Options:
1 to 10
Quadrus EZ Reader User’s Manual
10-7
Page 240
CCD Image Sensor Database
CCD Image Sensor Database The database indexes (arrays) of camera/image processing settings that are applied when one or more indexes are made active in IP Database Size. Note: The following commands apply to the CCD reader only.
CCD Database Index Definition:
Defines the specific database index (1 to 10) of settings that will be applied during operations. Each index (1 to 10) will have its own settings, for example <K250,1...>, <K250,2...>, etc.
Serial Cmd:
<K250,CCD database index,shutter speed,gain,threshold mode,threshold value,processing mode,background color,narrow margins>
Default:
0
Options:
1 to 10
Gain Serial Cmd:
<K250,CCD database index,shutter speed,gain,threshold mode,threshold value,processing mode,background color,narrow margins>
Default:
0
Options:
0 to 1023
Shutter Speed Serial Cmd:
<K250,CCD database index,shutter speed,gain,threshold mode,threshold value,processing mode,background color,narrow margins>
Default:
0
Options:
50 to 50,000
Threshold Mode Serial Cmd:
<K250,CCD database index,shutter speed,gain,threshold mode,threshold value,processing mode,background color,narrow margins>
Default:
0
Options:
0 = Adaptive
10-8
1 = Fixed
Quadrus EZ Reader User’s Manual