Page 37

DN120 DeviceNet Gateway User’s Manual Configure DeviceNet Interface Follow instructions in Chapter 4 to set the gateway’s rotary switches to 125Kbps baud rate and MAC ID to 03. Set the RS232 Baud Rate switch to PRG mode. Connect the gateway to the DeviceNet network to power it up. During power-up, the NET and MOD LEDs cycle through a sequence of alternating red and green. After power-up, the NET LED should be flashing green and the MOD LED should be solid green. Connect & Register EDS File 1) Start up the RSNetworx program. Select the Online operation from the Network menu.

Microscan Systems, Inc.

37

Page 38

DN120 DeviceNet Gateway User’s Manual

2) The following text box should pop up, showing the networks connected to your computer.

3) Click on the 1770-KFD-1 + to show all connected DeviceNet devices. The gateway is at MAC ID 03, verifying its DeviceNet connection. It is an Unrecognized Device until the gateway’s EDS file is registered with RSNetworx.

Microscan Systems, Inc.

38

Page 39

DN120 DeviceNet Gateway User’s Manual

4) Click Cancel to close Browse for network window. Select the EDS Wizard… operation from the Tools menu. Click Next> to continue.

5) Select the Register an EDS file(s) option and click Next>.

Microscan Systems, Inc.

39

Page 40

DN120 DeviceNet Gateway User’s Manual 6) Select Register a single file option. Browse for your gateway’s EDS file. You can download the latest EDS and ICON files from the www.microscan.com website. Click Next> when you have the correct path and EDS file name in the Named: box.

7) The next screen shows the RSNetworx installation test results. Click View file… to view the actual EDS file text. Click Next> to continue.

Microscan Systems, Inc.

40

Page 41

DN120 DeviceNet Gateway User’s Manual

8) The next screen allows you to customize the gateway’s icon for RSNetworx. Click on Change icon…

9) The Change Icon screen pops up. Click Browse to enter path for DN120 icon file. You can download the icon file from www.microscan.com.

Microscan Systems, Inc.

41

Page 42

DN120 DeviceNet Gateway User’s Manual

10) Enter the path to DN120 icon file in the File name: box. Click Open to continue.

11) The DN120 icon should have changed to the proper icon. Click Next to continue.

Microscan Systems, Inc.

42

Page 43

DN120 DeviceNet Gateway User’s Manual

12) The final step is to finish EDS file registration. Click Next> to complete the registration process. Click Finish to close the EDS Wizard window.

Microscan Systems, Inc.

43

Page 44

DN120 DeviceNet Gateway User’s Manual

13) Repeat steps 1, 2, and 3 to browse the DeviceNet network. RSNetworx should now recognize the device at MAC ID 03 as a DN120 gateway, and display the DN120 icon. Click Cancel when finished.

Microscan Systems, Inc.

44

Page 45

DN120 DeviceNet Gateway User’s Manual

Configure Serial Channel Once the gateway is connected to DeviceNet and communicating with RSNetworx, you can configure its serial channel. Make sure the gateway is not in the DeviceNet master scanlist before changing any attribute values. The Serial Stream Object attributes control the gateway’s serial channel transmit and receive operations. The following steps show how to configure the Serial Stream Object attributes using the RSNetworx program. 1) Select the Online operation from the Network menu. Select the DeviceNet adapter (1770KFD-1 in this example) and click OK.

2) RSNetworx prompts you to upload the network configuration. Click OK to continue.

Microscan Systems, Inc.

45