Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 13

MS-3000 Single Head Decoder User's Manual, pages 51 to 60

Pages 51 to 60 of 126

The original document is the PDF (730 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-3000

Page 51

User Outputs Menu

User Outputs Menu The User Outputs menu allows you to configure the decoder’s output. – Bold text represents default settings.

User Outputs Beeper Status

Beeper Speed

Beeper Volume

– On Noread – Disabled

– Fast

– Level 4

– Enabled

– Mismatch or

Noread

– Disabled

– Level 1

– Disabled

– Good Match

– Slow

– Level 5

New Master Pin – Enabled

– Mismatch – Noread

– Level 2

– Level 3

Laser On/Off – Disabled – Enabled

Reverse Video

Good/Bad Polarity

– Disabled – Enabled

– Positive

– Negative

Good/Bad Pulse Width* – 50 ms

– User Definable

(0 to 255)

Command Start Character – <

– User Definable

(ASCII char.)

Serial command Echo Beep on serial Command – Disabled – Enabled

– Disabled – Enabled

* Divide the number entered on the command line by 100 for time in s econds.

Figure 2-7 User Outputs Menu Structure

Beeper Default: On Good Options: On Good, On Noread, Disabled A beep is emitted either after each good read of a bar code label, after each noread, or not at all, according to the setting. Note: The beep period will be short for triggered modes where a new trigger occurs immediately or the output is delayed to the end of the read cycle on edge and serial triggers.

Beeper Volume Default: Level 4 Options: Level 4, Level 5, Level 1, Level 2, Level 3

MS-3000 Single Head Decoder User’s Manual

2-29

2–Menu Config.

– On Good

Full Screens Relay Driver

Page 52

Chapter 2

Menu Configuration

Beeper Speed Default: Fast Options: Fast, Slow Beeper Speed allows you to set the beeper to accommodate your application. The beeper takes approximately 80 ms to sound when Slow is enabled. If your application speed is faster than 80 ms (approximately), enable Fast.

2–Menu Config.

Full Screens Default: Enabled Options: Enabled, Disabled Allows you to display either the full menu screen or just the command line. When Full Screens is disabled, only the command line will be displayed.

Relay Driver Default: Mismatch Or Noread Options: Mismatch Or Noread, Good Match, Mismatch, Noread Note: All options (except Noread) require that you enable Match Code (page 2-19) and download a master label into memory. Allows you to determine the conditions under which a Relay Driver pulse of 5V is output. To see your options for enabling Match Code and downloading a master label into memory, see figure 2-5, “ Match Code Logic Diagram,” on page 2-20. Selecting:

Has this effect:

Mismatch or Noread

Sends a pulse to pin 2 of the trigger connector when a label’s data does not match that of the master label, or the label is not decoded before the end of the read cycle.

Good Match

Sends a pulse to pin 2 of the trigger connector when a label’s data matches that of the master label.

Mismatch

Sends a pulse to pin 2 of the trigger connector when a label’s data does not match that of the master label.

Noread

2-30

Sends a pulse to pin 2 of the trigger connector when no data is decoded before the end of the read cycle.

MS-3000 Single Head Decoder User’s Manual

Page 53

User Outputs Menu

New Master Pin

Laser On/Off Default: Disabled Options: Disabled, Enabled Note: A serial or external trigger (see “Triggering Mode” on page 2-14) must be enabled for Laser On/Off to take effect. When enabled, the laser is ON only during the read cycle. When disabled, the laser operates continuously. Note: Laser On/Off does not relate to the <H> (Enable Laser Scanning) or <I> (Disable Laser Scanning) operational commands on page 5-3.

Reverse Video Default: Disabled Options: Disabled, Enabled When enabled, the decoder will read bar code labels with bars that are lighter in color than their corresponding backgrounds.

Good/Bad Polarity Default: Positive Options: Positive, Negative Allows you to choose between positive and negative output signals for pins 6 (good read) and 8 (noread) on the host connector and pin 2 on the trigger connector.

MS-3000 Single Head Decoder User’s Manual

2-31

2–Menu Config.

Default: Disabled Options: Disabled, Enabled Note: Match Code (page 2-19) and a triggered mode (page 2-14) must be enabled for New Master Pin to take effect. Allows you to externally toggle pin 25 to momentarily bring it to ground (pin 7). This clears any existing master label information from memory and records the next good read as the new master label information.

Page 54

Chapter 2

Menu Configuration

Good/Bad Pulse Width

2–Menu Config.

Default: 5 (.05 seconds). Corresponds to 50 ms displayed in the menu. Options: 0 to 255 (0 to 2.55 seconds). Divide the number entered on the command line by 100 for time in seconds. Allows you to set the duration of the good read/no read output signals at host connector pins 6 and 8 by entering any number from 0 to 255. Caution: Too long of a pulse width can cause missed labels, especially if Good/ Bad Pulse Width exceeds End of Read Cycle Timeout (see page 2-16,).

Command Start Character Default: < Options: Any ASCII character. Allows you to define a new ASCII start character in a serial command.

Serial Command Echo Default: Disabled Options: Disabled, Enabled When enabled, serial configuration commands (“K” commands) will be processed and the new string for that command will be echoed back to the host. If an invalid command is sent to the host, the decoder will echo back the current setting of that command. For example, if the current Noread Message is “NOREAD” and <Kk1,NONSENSE> is entered, the decoder will echo back: <Kk1,NOREAD>. In this example the attempted entry “NONSENSE” exceeds the maximum allowable seven characters. Therefore it is rejected and the current NOREAD message is echoed back and remains the Noread Message. Note: It is important to note that if a command with multiple fields is processed, some of the fields may have been processed properly following an “invalid” command. These changes will be in the string echoed back so that the user will know what did or did not change.

Beep on Serial Command Default: Disabled Options: Disabled, Enabled When enabled, the decoder beeps once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the decoder beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response.

2-32

MS-3000 Single Head Decoder User’s Manual

Page 55

Raster Setup Menu

Raster Setup Menu Note: Raster Setup is applicable to the MS-1280 raster scan head only.

The Raster Setup menu allows you to set top and bottom offset values as well as the raster motor speed. – Bold text represents default settings.

Raster Setup

– Enabled – Disabled

Top Offset in Degrees – 0

– User

Definable (0 to 45)

Bottom Offset in Degrees

Sweeps per Second

– 45

2–Menu Config.

Status

– 14

– User Definable

– User

(0 to 45)

Definable (0 to 135)

Figure 2-8 Raster Setup Menu Structure

MS-1280 Raster Scan Head

Top Offset = 0°

Bottom Offset = 45° Figure 2-10 Raster Sweep Arc

Table 2-1 Raster Settings

Raster Arc

Sweeps per Second Minimum Maximum

1°

1

135

5°

1

75

10°

1

45

15°

1

35

20°

1

29

25°

1

23

30°

1

21

35°

1

19

40°

1

17

45°

1

14

Status Default: Enabled Options: Enabled, Disabled For additional information on raster setup see the MS-1280 Raster Scan Head User’s Manual.

Top Offset in Degrees Default: 0 (degrees) Options: 0 to 45 (in one-degree increments) MS-3000 Single Head Decoder User’s Manual

2-33

Page 56

Chapter 2

Menu Configuration Note: The top offset must always be less than the bottom offset or the resulting arc will be 0 degrees.

Top Offset in Degrees, along with Bottom Offset in Degrees, allows you to set the raster sweep arc. See figure 2-10.

Bottom Offset in Degrees

2–Menu Config.

Default: 45 (degrees) Options: 0 to 45 (in one-degree increments) Note: The bottom offset must always be greater than the top offset or the resulting arc will be 0 degrees. Bottom Offset in Degrees, along with Top Offset in Degrees, allows you to set the raster sweep arc. See Figure figure 2-10 on page 2-33.

Sweeps per Second Default: 14 Options: 0 to 135 Allows you to control the raster motor speed. A “sweep” is defined as a single pass, up or down, describing the raster image. table A-1 on page 2-33 shows minimum and maximum possible sweep speeds at selected raster arcs. The minimum possible speed at any arc is always one sweep per second. Maximum sweep speeds are the maximums to which the scan head defaults - even when you enter higher speeds. To maximize the number of scans a label will receive, select as few as possible sweeps per second. However, to ensure that the minimum required scan lines cross the bar code label, it is essential that at least two full sweeps occur during the time it takes for the label to pass through the readable scan width area. For example, if the label is readable in the read range for only 1/10th of a second, then the number of sweeps per second should be at least 20. If readable for only 1 second, then sweeps per second (SPS) should be at least 2. To see the formula for calculating sweeps per second, see the MS-1280 Raster Scan Head User’s Manual.

2-34

MS-3000 Single Head Decoder User’s Manual

Page 57

Chapter

3

Serial Configuration Chapter Contents

This chapter describes how to configure the MS-3000 single decoder by serial commands from a host. 1 All of the configuration parameters that can be changed in the menus with the exception of Full Screens, as described in Chapter 2, “ Menu Configuration,” can also be changed by serial configuration commands. All of the serial configuration parameters, with the exception of Trigger Filter Timing Value, also appear in the menus. In addition, most of these configuration parameters can also be changed with a Microscan profile card (P/N 99-500011-01), obtainable from your Microscan representative. (See Chapter 4, “ Profile Card Configuration.”) 1. The decoder communicates in full duplex, terminal mode with no handshake. It also recognizes carriage returns and line feeds. The host or ASCII terminal with must match the following default settings before any communication can take place: 9600 Baud Rate, Seven Data Bits, Even Parity, and One Stop Bit. If communicating from an auxiliary terminal via the auxiliary port (pins18 and 19 of the 25 pin connector), the serial command <D> (Enter Menu Configuration Program) is the only command that the decoder will recognize.

MS-3000 Single Head Decoder User’s Manual

3-1

3–Serial Config.

Summary of Serial Configuration Commands......................................3-2 Concatenating Serial Commands........................................................3-4 Serial Command Status Request.........................................................3-4 Loss of Communications......................................................................3-4 Trigger Filter Timing Value...................................................................3-5 Communications Commands...............................................................3-6 Operations Commands......................................................................3-10 Code Types Commands ....................................................................3-12 User Outputs Commands ..................................................................3-14 Raster Setup Commands...................................................................3-17

Page 58

The text of this page cannot be shown here; see it in the PDF.

Page 59

Function

Parameter

New Master Pin Laser On/Off Reverse Video Good/Bad Polarity

<Kzstatus> <KCstatus> <KDstatus> <Kwpolarity>

KE

Good/Bad Pulse Width Command Start Character

<Kxnumber> <KEASCII character>

KS

Verification Serial Command

KX

User Output Status Request Raster Setup (1280 only)

Kz KC

User Outputs

Format <Kubeeper status,beeper volume,beeper speed> <Kvmode>

Kv

KD Kw Kx

Raster

Command Beeper Relay Driver Usage

Ku

KR

<KSserial command echo status,serial command beep status, control/hex output> <KX?> <KRstatus,top offset,bottom offset,motor speed>

The format for a serial configuration command is, <Kparameterdata,data,...etc.><initializing command>

When using serial configuration commands, note also the following conventions: • Parameters and data are “case sensitive.” That is, characters must be entered as upper or lower case, as specified. • All data fields (except the last) must be followed by a comma (without a space). • If there is no change in a given field, then commas can be entered alone, or with the existing data (for example, <Ka,,,0> or <Ka4,1,0,0>). 1. Command start character by default is a left angle bracket, <. It may be redefined by menu or serial command. However, the end character, a right angle bracket, >, cannot be changed. 2. See “Initializing serial configuration commands” on page 3-4 for definitions and examples.

MS-3000 Single Head Decoder User’s Manual

3-3

3–Serial Config.

Where: • Less than < and greater than > symbols are included as part of the commands.1 • “parameter,” as used here, are those character(s) that precede the data. • The “initializing command” <A> or <Z> is sent after configuration is complete. <Z> resets and saves for power up. <A> initializes the change to RAM.2 (For more information, see page 5-3.) For example, the following command enables UPC and saves the change for power on: <Ks1><Z>.

Page 60

Chapter 3

Serial Configuration • All fields preceding the modified field must be included. For example, in the RS-232 port, to change Data Bits to Eight without changing any other field, enter either: <Ka,,,1> or <Ka4,1,0,1>. • All fields following the modified field can be left out. For example, in the RS-232 port, to change Baud Rate to 4800, enter <Ka3>. (See examples on following pages.)

Initializing serial configuration commands To ensure that a serial configuration command will take effect, you need to follow it with one of the operational commands below: <A> To reset but not save changes for power on <Z> To reset and save changes for power on For example, to change Baud Rate and reset without saving changes for power-up, enter <Ka3><A>. To change Baud Rate and reset, saving the changes to NOVRAM, enter <Ka3><Z>.

3–Serial Config.

Concatenating Serial Commands Commands can also be concatenated (added together) to a maximum of 64 characters in a single string or data block. Additional data blocks of 64 or less characters can be sent provided there is at least a 10 ms pause between blocks. 1 For example, the following command, <Kc1><KA24><Ko1><A> enables LRC, sets the Host Protocol Response Timeout to 24 ms, enables Narrow Margins and resets the data buffers (without saving the changes for power-on).

Serial Command Status Request The status of serial commands can be requested by entering the command followed by a question mark. For example, enter <Ke?> to request the status of Postamble. Commands KT?, KV?, KW?, KX?, and KU? are used to request the status of groups of serial commands (see table 3-1 on page 3-2).

Loss of Communications Assigning a multidrop address to a decoder or making changes to communications parameters such as Baud Rate, Parity, Stop Bits, LRC, etc. without corresponding changes in linked device(s) can result in the loss of menu access. If this should occur, try gaining access to the decoder by use of a pro1. Data in excess of 64 characters will reset the buffer, causing the first 64 characters of the string to be lost and indicator #1 to illuminate red 2 seconds after the end of each read cycle, until the decoder’s memory is reset.

3-4

MS-3000 Single Head Decoder User’s Manual