Page 31

Communications Menu

Preamble Default:

Preamble (enable/disable) Default: Disabled Options: Disabled, Enabled (within any protocol) Allows you to enable or disable the preamble character(s).

Postamble Default:

^M^J. Corresponds to <CR><LF> (carriage return/line feed) displayed in the menu. Options: Any ASCII character, including control characters. Control characters entered on the command line are displayed in the menu as mnemonic characters. See “ Defining Special Characters ,” on page 2-4 and Table A-2, “ ASCII Table with Control Characters ,” on page A-3. Allows you to define a one or two character data string that can be added after the decoded message. If User Defined, Polling Mode D, or Multidrop is enabled, the Postamble and Preamble characters are transmitted within the STX and ETX data block.

Postamble (enable/disable) Default: Disabled Options: Disabled, Enabled (within any protocol) Allows you to enable or disable the Postamble character(s).

MS-3000 Single Head Decoder User’s Manual

2-9

2–Menu Config.

^M (and a null). Corresponds to <CR><NUL> (carriage return/null) displayed in the menu. Options: Any ASCII character, including control characters. Control characters entered on the command line are displayed in the menu as mnemonic characters. See “ Defining Special Characters ,” on page 2-4 and table A-2 on page A-3. Allows you to define a one or two character data string that can be added to the front of the decoded data. For example, a carriage return and line feed would display each decoded message on its own line. If User Defined, Polling Mode D, or Multidrop is enabled, the Preamble and Postamble characters are transmitted within the STX and ETX data block.

Page 32

Chapter 2

Menu Configuration

Longitudinal Redundancy Check Default: Disabled (in unpolled mode), Enabled (in polled mode) Options: Disabled, Enabled An error-checking routine that verifies the accuracy of transmissions. It is the exclusive OR of all characters following the SOM (start of message) up to and including the EOM (end of message).

2–Menu Config.

Response Timeout Default: 12 ms Options: 0 to 65,000 ms. A zero (0) causes an indefinite wait. Allows you to set the time the decoder will wait before timing out if ACK, NAK, and ETX are enabled, and a host response is expected.

Intercharacter Delay Default: 0. Corresponds to 0 ms displayed in the menu. Options: 0 to 255. A zero (0) causes no delay between characters. Allows you to set the time interval in milliseconds between individual characters transmitted from the decoder to the host. A high setting will significantly slow down communications. For example, a 200 setting will result in a 1/5 second delay between each character that is transmitted.

Host Port Parameters Allows you to set parameters for host port communications.

Baud Rate Default: 9600 Options: 9600, 19.2K, 38.4K, 600, 1200, 2400, 4800 Allows you to set the number of bits transmitted per second. NOTE: Due to timing considerations, polled modes require 2400 baud or faster.

Parity Default: Even Options: Even, Odd, None Allows you to select an error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd.

2-10

MS-3000 Single Head Decoder User’s Manual

Page 33

Communications Menu

Stop Bits Default: One Options: One, Two Allows you to select the last one or two bits in each character to indicate the end of the character.

Data Bits

RS-422 Default: Disabled Options: Disabled, Enabled Note: Used only in Point-to-Point protocol only, and not with RTS/CTS. Whenever RS-422 is disabled, RS-232 is enabled in the background. However, when Multidrop is enabled, the functioning protocol is RS-485 regardless of the displayed status of RS-422 in the menus. Before enabling RS-422, first double-check that Multidrop is not enabled. (See “ Protocol,” on page 2-6.) (See Appendix G, “Interface Standards,” on page A-12 for additional information on RS-422.)

Aux Port Parameters Aux Port (auxiliary port) allows you to set communications settings between the decoder and an auxiliary monitor. An auxiliary monitor can be used to configure the menus, send data to the host, and display data transmissions originating from the host or decoder. Note: Aux Port operates in RS-232 only. See Appendix H, “Auxiliary Monitor,” on page A-13 for a full description of auxiliary port options.

MS-3000 Single Head Decoder User’s Manual

2-11

2–Menu Config.

Default: Seven Options: Seven, Eight Allows you to establish the total number of bits in each character.

Page 34

Chapter 2

Menu Configuration

Aux Mode Default: Disabled Options: Disabled, Transparent, Half Duplex, Full Duplex Aux Mode (auxiliary mode) allows you to select a communications mode for auxiliary operations (see Appendix H, “ Auxiliary Monitor,” on page A-13).

Other Aux Port Parameters 2–Menu Config.

The other Aux Port parameters - Baud Rate, Parity, Stop Bits, and Data Bits - are identical to the host port parameters and are changed in the same manner (see page 2-10). Note: The Aux Port baud rate should never exceed Host Port baud rate or auxiliary port data could be lost.

2-12

MS-3000 Single Head Decoder User’s Manual

Page 35

Operations Menu

Operations Menu The Operations menu allows you to set the operations parameters for the decoder. To help visualize the menu’s organization and to locate the page number where each topic is described, see figure 2-3. – Bold text represents default settings.

Operations

– Continuous Read

– Continuous Read 1

Output – External Level – External Edge – Serial Data – Serial Data & Edge

– Timeout &

New Trigger

– User Definable

– Negative

Possible – End of Read Cycle

– New Trigger

– NOREAD

– Positive

– As Soon As

– Timeout

Noread Message (7 digits)

External Trigger Polarity

When to Output

End of Read Cycle

(ASCII char.)

Number of Reads – 1

– User

Definable (1 to 31)

Match Code – Disabled – Enabled

Timeout in 10 ms incs * – 100

Serial Trigger Character – ^]

– User Definable

– User

Noread Message

Bar Code Output

(ASCII char.)

Definable (ASCII char.)

– Enabled

– Enabled

Number of Labels

Field Separator

– Disabled

– 1

– User

Definable (1 to 6)

– Disabled

– , (comma) – User

Definable (ASCII char.)

* Divide the number entered on the command line by 100 for time in seconds.

Figure 2-3 Operations Menu Structure

MS-3000 Single Head Decoder User’s Manual

2-13

2–Menu Config.

Triggering Mode

Page 36

Chapter 2

Menu Configuration

Triggering Mode

2–Menu Config.

Default: Continuous Read Options: Continuous Read, Continuous Read 1 Output, External Level, External Edge, Serial Data, Serial Data & External Edge Allows you to establish the type of trigger event that will initiate or end the read cycle. (See “End of Read Cycle” on page 2-16.) Selecting:

Has this effect:

Continuous Read

Trigger input options are disabled and the decoder is always in the read cycle. Bar code data is decoded, and label information is transmitted repeatedly, as long as the label is in the range of the scan head. When To Output options have no affect on Continuous Read. Continuous Read is useful in testing label or scan head functions.

NOTE: If Continuous Read is enabled with Match Code, the decoder defaults to Continuous Read 1 Output mode.

Continuous Read 1 Outputa NOTE: Enabling Continuous Read 1 Output when Number of Labels (page 2-21) is set to any number greater than one will cause Number of Labels to default back to one.

External Level

2-14

Label data is immediately transmitted with Timeout enabled for End Of Read Cycle. If the label doesn't change, the decoder will repeat the output at the end of each subsequent timeout period. For example, if Timeout were set to one second, the decoder would output the label data immediately, and then repeat the output at intervals of one second, for as long as the label continued to be scanned. With Timeout disabled (that is, End Of Read Cycle set to New Trigger), the decoder will output the current label data immediately, but output it only once. A new label appearing at any time in the scan range will produce a new read output as long as the new label is not identical to the previous label. Allows a read cycle to be initiated by a trigger signal from an object detector when an object appears within the detector’s range. The read cycle endures until the object moves out of the detector’s range (figure -4 on page -15), unless a timeout occurs and Timeout is enabled for End of Read Cycle (page 2-16).b

MS-3000 Single Head Decoder User’s Manual

Page 37

Operations Menu Has this effect:

External Edge

As with Level, Edge allows a read cycle to be initiated by a trigger signal from an object detector when it detects the appearance of an object (rising edge). But unlike Level mode, the removal of an object (falling edge) does not end the read cycle. With Edge enabled, the read cycle ends with a good read, a timeout, or a new trigger (figure -5).

Serial Data

The decoder accepts an ASCII character from the host or controlling device as a trigger to start a read cycle.

Serial Data & External Edge

The decoder accepts either an external trigger or a serial ASCII command to start a read cycle.

a. Continuous Read 1 Output will allow an output regardless of how Good Decode Read is set. b. Level and Edge apply to the active logic state (positive or negative) that exists while the object is in a read cycle, between the rising edge and falling edge. For the purpose of this discussion,rising edge is the trigger signal associated with the appearance of an object andfalling edge is the trigger signal associated with the subsequent disappearance of the object.

First trigger An object, moving in front of the detector beam, causes the first trigger (rising edge trigger) signal to be sent to the decoder, initiating the read cycle.

1

Object detector

1

Object detector

2

1

Object detector

Second trigger The same object, moving out of the detector's beam, causes a second trigger (falling edge trigger) signal to be sent to the decoder, ending the read cycle.

Figure 2-4 External Level Trigger Signals

Object detector

First rising edge trigger Object #1, moving in front of the detector beam, causes the first trigger (rising edge trigger) signal to be sent to the decoder, initiating the read cycle. Subsequent rising edge trigger Object #2, moving in front of the detector's beam, causes a second trigger (rising edge trigger) signal to be sent to the decoder. This signal initiates a new read cycle and ends the previous read cycle provided that New Trigger or Timeout and New Trigger is enabled and a good read or timeout has not already occurred.

Figure 2-5 External Edge Trigger Signals

MS-3000 Single Head Decoder User’s Manual

2-15

2–Menu Config.

Selecting:

Page 38

Chapter 2

Menu Configuration

End of Read Cycle

2–Menu Config.

Default: Timeout Options: Timeout, New Trigger, Timeout & New Trigger Allows you to choose the conditions that will end the read cycle. The read cycle is the time during which the decoder will receive and process label data. When the Triggering Mode option is set in an External or Serial mode of operation, the trigger event initiates the read cycle. Note: The Aux Port baud rate should never exceed Host Port baud rate or auxiliary port data could be lost.

2-16

Selecting:

Has this effect:

Timeout

Can end the read cycle after a specified period of time, and if no label has been read, causes a noread message, if enabled, to be transmitted. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout ends the read cycle. With External Level enabled, the read cycle does not end until the falling edge trigger occurs, and the next read cycle does not begin until the next rising edge trigger. With Continuous Read 1 Output enabled, a timeout initiates a new read cycle and allows the same label to be read again.

New Trigger

Ends the read cycle at the occurrence of a new trigger event, and if no label has been read, causes a noread message, if enabled, to be transmitted at the occurrence of the new trigger event. With either External Edge, Serial Data, or Serial Data & Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. With External Level enabled, a falling edge trigger ends a read cycle. However, the next read cycle does not begin until the occurrence of the next rising edge trigger.

MS-3000 Single Head Decoder User’s Manual

Page 39

Operations Menu Has this effect:

Timeout & New Trigger

Ends the read cycle after a specified period of time or at the occurrence of new trigger event, and if no label has been read, causes a noread message, if enabled, to be transmitted. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout, or an edge or serial trigger, whichever comes first, ends the read cycle. An edge or serial trigger also initiates a new read cycle. With External Level enabled, the read cycle does not end until the occurrence of a falling edge, and the next read cycle does not begin until the next rising edge trigger.

Timeout (in 10 ms incs) Default:

100 (one second). Corresponds to 1000 ms displayed in the menu. Options: 0 to 65535. Divide the number entered on the command line by 100 for time in seconds. Note: Timeout or Timeout & New Trigger under End of Read Cycle (page 2-16) must be enabled for Timeout (in 10 ms incs) to take effect. Allows you to define the duration of the timeout period.

Serial Trigger Character Default: ^]. Corresponds to <GS> displayed in the menu. Options: Any single ASCII character , including control characters, except a NUL (00H), an existing host command character, 1 or an on-line protocol character. Control characters entered on the command line are displayed in the menu as mnemonic characters. See “Defining Special Characters ” on page 2-4 and Table A-2, “ ASCII Table with Control Characters ,” on page A-3. Note: Serial Data (page 2-15) or Serial Data & Edge (page 2-15) must be enabled for Serial Trigger Character to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled. Allows you to define a single ASCII character as the host serial trigger character that initiates the read cycle. The serial trigger is considered an on-line host command and requires the same command format as all host commands (that is, to be entered within the < > brackets). 1. For example, assigning an upper case D would nullify the <D> (Enter Menu Configuration) command. For a list of operational commands used by the decoder, see table A-1 on page 5-2. MS-3000 Single Head Decoder User’s Manual

2-17

2–Menu Config.

Selecting:

Page 40

Chapter 2

Menu Configuration

External Trigger Polarity

2–Menu Config.

Default: Positive Options: Positive, Negative Note: External Level (page 2-14), External Edge (page 2-15), or Serial Data & Edge (page 2-15) must be enabled for External Trigger Polarity to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled. Allows you to determine whether a positive or negative transition will initiate the read cycle. Note: If using the Microscan object detector (P/N 99-440001-03), use positive trigger polarity.

Noread Message Default: NOREAD Options: Up to seven ASCII characters (except a NUL). Allows you to define any combination of ASCII characters (except a NUL) up to seven characters as the noread message. The noread message, if enabled and if no bar code label has been decoded, will be transmitted to the host at a timeout or the end of a read cycle.

Noread Message (enable/disable) Default: Enabled Options: Enabled, Disabled Note: If Noread Output is enabled, the noread message will only output if Bar Code Output is also enabled. Allows you to enable or disable the noread message.

Bar Code Output Default: Enabled Options: Enabled, Disabled Allows you to choose whether or not to send label data (or noreads) to the host. When disabled, a label is decoded and the read cycle transpires as usual, but neither label data nor the noread message is transmitted to the host. All decoder counters are updated, and the number of good reads or noreads can be obtained via operational commands.

When to Output Default: As Soon As Possible Options: As Soon As Possible, End of Read Cycle 2-18

MS-3000 Single Head Decoder User’s Manual