For the Microscan MS-3000

Page 101

Troubleshooting Problem

Decoder does not transmit or decode labels (decoder indicator lights on but no data is displayed on screen)

Possible Cause

Solution

Decoder is not triggered when in external mode.

Ensure trigger device is operating properly. Do Read Rate Test <C>. If it reads successfully, the problem is triggering.

Decoder is not triggered when in serial mode.

Ensure serial trigger character is sent with start/ stop characters (a left angle bracket < (unless redefined) and a right angle bracket >).

Power supply problem

Have technician measure AC input voltage and power supply DC output voltages. Replace if power supply is not supplying correct voltages.

External electrical noise

See “Ground and Shield Considerations,” on page 1-14.

Incorrect firmware for application

Some applications may require custom firmware. Call your Microscan representative.

Scan head is not connected properly

Ensure that the modular cable is inserted into the modular connectors. Inspect cable for damage. If questionable, try another cable.

Scan head Laser scanning disabled Enable laser scanning with the <H> serial motor does not by the <I> serial command command rotate and laser Disable Laser On/Off to make the laser operis off ate continuously. Otherwise, decoder is operLaser On/Off enabled (determine ating correctly; Laser On/Off activates the motor movelaser during the read cycle only. ment by feel Laser may not be functioning. If motor is not or sound) Faulty scan head rotating and the laser is off, try another scan head Faulty cable to scan head Getting only “hieroglyphics” or unintelligible code Getting only noread messages on the screen

Try another scan head cable.

Check Baud Rate and Parity and change to Host and decoder baud rates or parity not matched match host's settings.

Bar code label not readable

Try another label that is known to be readable. (Ensure that the new label is the same code type and density.)

Incorrect label range

Refer to scan head range data in scan head manual to determine correct range. Reposition label and perform the read rate test.

MS-3000 Single Head Decoder User’s Manual

A-7

Appendices

Table A-3 Troubleshooting Table (continued)

Page 102

Appendices Appendices

Table A-3 Troubleshooting Table (continued)

Problem

Getting only noread messages on the screen

Previous label read, but subsequent label will not read Decoder not communicating in polled mode.

Decoder not entering read cycle (trigger not working)

Decoder not reading during the read cycle

A-8

Possible Cause

Solution

Label misaligned or reflecting direct laser light

Ensure the label is not excessively skewed, tilted, or otherwise disoriented. Ensure the bar code is in the scan line when it is supposed to be. Ensure that the bar code is pitched so as to avoid specular light.

Triggering/timeout out of sync

Review triggering and timing (chapter 2).

Remedy by remounting, eliminating interference, or shielding. Object detector or another scan head interfering with Many object detectors emit pulsed infrared signals that can seriously degrade the read reads rate if they shine into the scan head or onto the bar code label when it is being read. No signal received from the scan head

Check scan head/decoder cable, substitute another scan head, and/or see scan head troubleshooting table.

Decoder configured in Continuous One mode with New Trigger enabled

Scan a label that contains different data than that of one being read, or change End of Read Cycle to Timeout.

Decoder in polled mode

Check communications protocol.

LRC disabled

Enable LRC.

Improper configuration

Check communications parameters (with Aux port, profile card or by defaulting unit and resetting).

Faulty or improper cabling See “Attach Cabling,” on page 1-3 for cabling or ground advice or refer to multidrop manual. Proper trigger levels not enabled

Ensure that the trigger pulse and the trigger polarity settings are correct.

Ensure that the trigger circuit wiring meets the Trigger circuit not correctly decoder requirements (see “Attach Cabling,” wired on page 1-3). Object detector inoperative

Check detector range and sensitivity. Try a detector that is known to be good.

Object detector not positioned properly

Ensure read cycle is active during the time the label is in the scan line.

End of read cycle not properly defined for the application

Ensure that the proper end of read is defined in decoder configuration.

MS-3000 Single Head Decoder User’s Manual

Page 103

Interfacing with the MS-90 Scan Head

This appendix describes Label Speed, a User Outputs option (see figure A5) that is exclusive to the MS-90 scan head. When using a MS-90 scan head with an MS-2000/ 3000 decoder, it is necessary to install MS-90 firmware (35-213034-XX) that makes Label Speed available.1 Other than the differences noted in this appendix, configuration for the MS90 is identical to standard single scan head configuration described in this manual.

Label Speed Default: Options:

CURRENT SETTINGS FOR USER OUTPUTS BEEPER BEEPER VOLUME LABEL SPEED FULL SCREENS RELAY DRIVER NEW MASTER PIN GOOD/BAD POLARITY GOOD/BAD PULSE WIDTH

ESC = MAIN MENU OR EXIT M = PREVIOUS MENU B = PREVIOUS ITEM

= ON GOOD = LEVEL 4 = MEDIUM = ENABLED = MISMATCH OR NOREAD = DISABLED = POSITIVE = 50 ms

N = NEXT ITEM SP = NEXT ITEM CR = THIS ITEM

USER OUTPUTS - - > BEEPER = ON GOOD

Figure A-5 MS-90 User Outputs Menu (with Label Speed Option)

Medium Medium, Fast, Slow

Allows you to select a response time to match a specific label speed. For information on navigating the menus, see “ Using the Menu Configuration Program,” on page 2-2. The serial command format is explained below: Format: <KYlabel speed> label speed: 0 = Slow 1 = Medium 2 = Fast Example: To set Label Speed to Fast, enter: <KY2> Note: When Label Speed is set to Fast, the beeper must be disabled.

1. The MS-90 firmware does not support Aux Port, New Master Pin, Beeper Speed, or the Microscan profile card. MS-3000 Single Head Decoder User’s Manual

A-9

Appendices

Appendix E, Interfacing with the MS-90 Scan Head

Page 104

Appendices Appendices

Setting the correct label speed is important when using the MS-90 with the MS-3000 decoder. Tables A-6 and A-7 show label speeds in inches per second for Slow, Medium, and Fast menu label speeds for 2.5:1 ratio (as used in Code 39) and 4:1 ratio (as used in Code 128) respectively. In general, the medium and fast settings will correspond with the high speed scan head and the slow setting will correspond with the low speed scan head (for more information, see the MS-90 Scan Head User’s Manual ). Table A-4 Label Speeds for Code 39 in Inches per Second

Narrow Bar Width Type

Menu Setting SLOW:Min. Max. MEDIUM:Min. Max. FAST:Min. Max.

(wide-to-narrow ratio of 2.5:1)

6 mil. 0.4 10 2.5 57 18 368

7.5 mil. 0.5 12.9 3.1 71 29 460

10 mil. 0.7 17 4.2 95 30 600

15 mil. 1.0 25.9 6.3 143 45.6 600

20 mil. 1.4 34 8.3 190 61 600

30 mil. 2.1 52 12.5 286 91 600

Table A-5 Label Speeds for Code 128 in Inches per Second

Narrow Bar Width Type

Menu Setting SLOW:Min. Max. MEDIUM:Min. Max. FAST:Min. Max.

A-10

(wide-to-narrow ratio of 2.5:1)

6 mil. 0.7 10 4 57 29 368

7.5 mil. 0.9 12.9 5 71 36 460

10 mil. 1.1 17 6.7 95 48 600

MS-3000 Single Head Decoder User’s Manual

15 mil. 1.7 25.9 10 143 73 600

20 mil. 2.2 34 13.3 190 97 600

30 mil. 3.3 52 20 286 146 600

Page 105

Bar Code Symbology Appendices

Appendix F, Bar Code Symbology Some factors to consider before choosing a bar code symbol are: 1 • the type of information to be scanned (numeric only, alphanumeric)

• the length of the messages to be encoded • how and where labels are to be applied • label printer capabilities

• scan speed • beam width • the space available on the object to be identified • host software limitations • range of the scan head • the speed of the conveyor

Microscan standard decoder firmware supports the following five bar code symbologies. (Firmware can also be custom ordered to support other symbologies.) Code 39. An alphanumeric code with unique start/stop code patterns, composed of 9 black and white elements per character, 3 of which are always wide. Codabar. A 16-character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and 18 different bar widths. I 2 of 5. Interleaved 2 of 5 is a high-density, continuous numeric symbology. I 2 of 5 encodes two digits: one in the bars, and one in the spaces. (A check digit is highly recommended.) UPC and EAN. UPC (Universal Product Code) is a fixed length numeric, continuous symbology. The European Article Numbering system (EAN) is a well-known variation of UPC. Both UPC and EAN can have 2 or 5 digit supplemental bar code data following the normal code. Code 128. A very high density alphanumeric symbology. Will encode all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge.

1. For further information about symbology, see The Bar Code Book, by Roger C. Palmer, Helmers Publishing, Inc., 1989. MS-3000 Single Head Decoder User’s Manual

A-11

Page 106

Appendices

Appendices

Appendix G, Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. With Microscan devices, selection of interface is made by pin assignment and, in the case of the host communications, by software switching between RS-232 and RS-422. Microscan devices use RS-232, RS-422, and RS-485 multidrop.

RS-232 RS-232 defines an interface between two devices such as, for example, the decoder and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (15.2 m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.

RS-422 RS-422, unlike RS-232, measures signals differentially that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219.2 m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line. It can be used wherever RS-232 is used.

RS-485 RS-485, like RS-422, can transmit up to 4000 feet (1219.2 m) using differential voltages but unlike RS-422, its transmitters are turned off until a request for data is received from the host. RS-485 is used exclusively in Multidrop protocol. Note: See “Protocol,” on page 2-6 for additional information on standards.

A-12

MS-3000 Single Head Decoder User’s Manual

Page 107

Auxiliary Monitor Appendices

Appendix H, Auxiliary Monitor An auxiliary monitor, via a 9-pin cable connected to the decoder with a D-subminiature connector, can: 1. Echo data from the decoder or host. 2. Send data to the host. 3. Access and make changes to the decoder's configuration menus. The monitor can be configured to operate in one of three modes: • Transparent • Non-Buffered Half Duplex • Non-Buffered Full Duplex Note: Transparent can be used with all protocols. Full Duplex and Half Duplex operations can be used with any protocol except polled protocols. (Polling Mode D, Multidrop, User Defined, and User Defined Multidrop).

Transparent Mode Used to batch data from the monitor to the host. The decoder buffers data from the monitor and displays the keyed data on the monitor. The decoder transmits monitor data to the host when a label is scanned or a carriage return is entered from the monitor.

Data Initiated from the Monitor • Monitor data is passed through to the host whenever a return key is pressed at the monitor or whenever bar code data is sent. If sent with bar code data, it is processed on a firstin/first-out basis.

Monitor

Host

• Monitor data to the host is always sent with a preamble and a postamble. • If the decoder is in a polled mode to the host, monitor data will still pass through.

PWR

TRIG

SCAN

IND 1

IND 2

MS-3000 Decoder

• A <D> command is the only command accepted by the decoder from the monitor. All other commands will pass through to the host.

MS-3000 Single Head Decoder User’s Manual

A-13

Page 108

Appendices Appendices

Data initiated from the Decoder • Transmission to the monitor occurs immediately upon a good read. • Scan data to the monitor does not include a preamble or a postamble. • Communications with the monitor is always in Point-to-Point protocol, even if the host is in a polled protocol mode.

Monitor

Host

Data initiated from the Host

PWR

TRIG

• In polled mode, data echoed from the host to the monitor must be in the format <B ____> (e.g., to send the word “LUNCH” to the monitor, it must be sent in the format <BLUNCH>).

SCAN

IND 1

IND 2

MS-3000 Decoder

• In unpolled mode, all host data is echoed to the monitor.

Monitor

Host

Half Duplex Mode In half duplex mode all monitor data and bar code data is sent directly to the host. Bar code data is displayed on the monitor screen at the same time the data is sent to the host.

PWR

TRIG

SCAN

IND 1

IND 2

MS-3000 Decoder

Data initiated from the Monitor • Monitor data to the host is ignored if the decoder is in a polled mode. • Monitor data or scanned data is sent to the host whenever it is received. • Monitor data is not echoed.

Monitor

Host

• Monitor data to the host is always sent without a preamble or a postamble.

PWR

TRIG

SCAN

IND 1

IND 2

MS-3000 Decoder

A-14

MS-3000 Single Head Decoder User’s Manual

Page 109

Auxiliary Monitor

Data initiated from the Decoder • Scan data is transmitted to the monitor at the same time it is transmitted to the host.

Monitor

Host

• Data transmission conforms with all parameters specified in the configuration menu (e.g., Preamble, Postamble, End of Read Cycle).

PWR

TRIG

IND 1

SCAN

IND 2

MS-3000 Decoder

Data is initiated from the Host • In polled mode, data echoed from the host to the monitor must be in the format <B____> (i.e.: to send the word “LUNCH” to the terminal, it must be sent in the format <BLUNCH>).

Monitor

Host

• In unpolled mode, all host data is echoed to the monitor. Note: For connection diagrams, see Chapter 1, “Setup and Installation .”

MS-3000 Single Head Decoder User’s Manual

PWR

TRIG

SCAN

IND 1

IND 2

MS-3000 Decoder

A-15

Appendices

• <D> is the only command that is accepted by the decoder from the monitor. All other commands are passed through to the host.

Page 110

Appendices Appendices

Full Duplex Mode In full duplex mode, all monitor data and bar code data is sent directly to the host. Bar code data is not displayed on the monitor screen.

Data initiated from the Monitor • Monitor data is passed directly through to the host whenever it is received by the MS-3000, unless the decoder is in a polled mode, in which case the data will be ignored.

Monitor

Host

• Monitor data is not echoed. • Monitor data to the host will not have a preamble or a postamble.

PWR

TRIG

• A <D> command is the only command accepted by the decoder from the monitor. All other commands will pass through to the host.

SCAN

IND 1

IND 2

MS-3000 Decoder

Data initiated from the Decoder • Scan data is not sent to the monitor. Monitor

Host

PWR

TRIG

SCAN

IND 1

IND 2

MS-3000 Decoder

Data initiated from the Host • In polled mode, data echoed from the host to the monitor must be in the format <B____> (for example, to send the word “LUNCH” to the terminal, it must be sent in the format <BLUNCH>).

Monitor

Host

• In unpolled mode, all host data is echoed to the monitor.

PWR

TRIG

SCAN

IND 1

IND 2

MS-3000 Decoder

A-16

MS-3000 Single Head Decoder User’s Manual