The text of a manual · part 8 of 13
MS-3000 Dual Head Decoder User's Manual, pages 71 to 80
Pages 71 to 80 of 126
The original document is the PDF (779 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-3000
Page 71
Raster Setup Commands
Raster Setup Commands Format: <KRstatus,top offset,bottom offset,motor speed> top offset in degrees: status: 0 = Disabled 1 = Enabled Any number from 0 to 45. Default is 0. bottom offset in degrees: motor speed (in sweeps per second): Any number from 0 to 45. Any number from 0 to 135. Default is 14. Default is 45. Example: To set the raster arc to 35º and the raster motor speed to 10 sweeps per second, enter <KR1,5,40,10>.
3–Serial Config.
MS-3000 Dual Head Decoder User’s Manual
3-15
Page 72
Chapter 3 Serial Configuration
7) = iS ° 1S) © = o at o
3-16 MS-3000 Dual Head Decoder User’s Manual
Page 73
Chapter
4
Profile Card Configuration
Chapter Contents Summary of Profile Card Modes..........................................................4-2 Operating Instructions..........................................................................4-3 General Settings ..................................................................................4-4 Communications Settings ....................................................................4-5 Operations Settings .............................................................................4-8 Code Types Settings..........................................................................4-10 User Outputs Settings........................................................................4-10 Binary Calculations ............................................................................4-12
The profile card (P/N 99-500011-01), available from Microscan as an accessory, is not essential to the operation of the decoder. All configuration commands performed by the profile card can also be done by menu or serial command. However, a profile card can speed up configuration and is particularly useful for copying configuration from one decoder to another and for configuring devices that have been given multidrop addresses.
MS-3000 Dual Head Decoder User’s Manual
4-1
4–Profile Card.
Note: Not all configuration changes that can be done by menu configuration can be done with the profile card.
Page 74
Chapter 4
Profile Card Configuration
Summary of Profile Card Modes Table 4-1 Profile Card Mode Descriptions
Mode
0
1 2
Assign Multidrop Address
4 5 6 7
8
4–Profile Card.
Write-to-Device Function Read Function Default Menu Write & Assign Address
3
9 10 11 12 13
14
4-2
Parameter
Baud Rate Parity Stop Bits Data Bits Preamble Postamble Protocol RS-422 Aux Port Triggering Mode End of Read Cycle Bar Code Output When to Output Trigger Polarity Edge or Level Noread Message System Timeout in 10 ms inc. Serial Trigger Character Number of Reads Narrow Margins Code Types Beeper Volume Beeper Relay Driver Usage Full Screens Data Line Polarity Data Line Usage Laser On/Off Reverse Video
Function Downloads (copies) all of the configuration parameters from the profile card to the connected decoder. Uploads configuration data from the volatile RAM of the decoder to the non-volatile RAM of the profile card. Sets unit to the default configuration settings. Enters the menu program while decoder is in polled mode. Combines the write function from mode 0 with the address function of mode 2. Downloads a multidrop address as well as all of the configuration parameters in the profile card. Assigns user-selected multidrop address to the decoder by using data switches 1-6. Binary representation of the multidrop address is used (the range is 1 to 50). Defines Baud Rate for the host port. Defines Parity for the host port. Defines Stop Bits for the host port. Defines Data Bits for the host port. Enables/disables Preamble. Enables/disables Postamble. Defines the communications protocol. Enables/disables RS-422. Sets Aux. Port operation mode. Defines Triggering Mode. Defines End of Read Cycle. Enables/disables Bar Code Output. Defines the conditions for When to Output. Defines External Trigger Polarity (negative/positive). Defines External Trigger as Edge or Level. Enables/disables Noread Message. Sets the trigger timeout value. The range is 1-255 for corresponding values of 0.1 to 25.5 seconds. Assigns the Serial Trigger Character. (See the ASCII table on page A-3 for decimal values and corresponding characters.) Sets the number of reads for a good decode from 1-31. Enables/disables Narrow Margins for all code types. Enables individual bar code types or Autodiscriminate. Sets the beeper volume. Sets the conditions when the beeper is emitted. Sets Relay Driver Usage to Good Read or Noread. Enables/disables Full Screens. Sets the Polarity of output pulses. Sets Data Line Usage to Good Read or Noread. Enables/disables Laser On/Off. Enables/disables Reverse Video.
MS-3000 Dual Head Decoder User’s Manual
Page 75
Profile Card Configuration
Operating Instructions
2. Turn decoder ON. 3. Set the mode and data switches to the desired settings.
ON
OFF
DECODER
1. With the decoder OFF, insert the end of the profile card which is labeled DECODER into the port labeled HOST on decoder.
LOAD
PROFILE CARD
O 1 2 3 4 5 6 7 8 DATA N
O 1 2 3 4 N
TERMINA L
The profile card obtains all operating voltages from the decoder. Turn the decoder off before starting procedures.
MODE
Figure 4-1 Profile Card
Data switches are on the left, mode switches on the right. Note: Be sure all of the data switch settings are correct for the selected mode before pressing the load button. 4. Press the LOAD button. 5. A beeper will sound. This initializes the change and saves it to non-volatile RAM for access on power-up. 6. When the configuration is complete, turn power OFF to the decoder and remove the profile card.
MS-3000 Dual Head Decoder User’s Manual
4-3
4–Profile Card.
If using RS-232 (only) and communication between the host and the decoder is desired with the profile card, connect a cable to the profile card end labeled TERMINAL and connect it to the host.
Page 76
Chapter 4
Profile Card Configuration
General Settings Mode 0: Write, Read, Default, Menu Mode Switches
= On = Off
Data Switches
1 2 3 4
Write Read Default Menu
Note: Unintentional defaults may occur when using the profile card‘s write functions (modes 0 and 1) to copy configuration changes from versions -26 and earlier to versions -27 and later (and vice versa), and when copying from versions -27 through -31 to versions -32 and later (and vice versa) of Microscan standard firmware. 1 To solve, you can change all EPROMs to the same firmware version, use a separate profile card for each version group, or use a single profile card to first make all configuration copy changes within one group (those with all earlier or all later versions) and then, after individually changing the settings in one decoder of the second group, copying them to the other decoders in that group. Mode 1: Write Configuration and Assign Address
4–Profile Card.
Mode Switches
= On = Off Data Switchesa Address Address
Address
1 2 3 4 5 6
1 2 3 4 5 6 1
Address
1 2 3 4 5 6
14
1 2 3 4 5 6 27
40
1. The firmware number is 35-213002-XX for the MS-3000 dual head decoder. The XX is substituted here for the version number. The firmware version can be found on a label on the EPROM, displayed in the heading of the Main menu in the Configuration program, or on later versions, displayed by invoking the <#> serial operational command. You can also call-in the serial numbers of the decoders to Microscan to get the firmware versions issued with those decoders.
4-4
MS-3000 Dual Head Decoder User’s Manual
Page 77
Profile Card Configuration Mode 1: Write Configuration and Assign Address Mode Switches
= On = Off
2
15
28
41
3
16
29
42
4
17
30
43
5
18
31
44
6
19
32
45
7
20
33
46
8
21
34
47
9
22
35
48
10
23
36
49
11
24
37
50
12
25
38
26
39
13 a. Use these switch settings for mode 2, 9, 10, and 11.
Communications Settings
Mode 2: Address Mode Switches
= On = Off
Address selection for mode 2 is identical to mode 1. See mode 1 for switch settings.
MS-3000 Dual Head Decoder User’s Manual
4-5
4–Profile Card.
Note: Changes in Communications parameters or assigning an address to the decoder can cause loss of communications with the configuration terminal when you exit the menu program (whether or not changes are saved for power-on).
Page 78
Chapter 4
Profile Card Configuration Mode 3: Host Port Baud Rate, Parity, Stop Bits, Data Bits Mode Switches
= On = Off
Baud Rate
Parity
Data Switches Stop Bits
123
45
6
Data Bits
7
600
None
One
Seven
1200
Even
Two
Eight
2400
Odd
4800 9600 19200 38400 Mode 4: Preamble, Postamble Mode Switches
= On = Off
Preamble
Data Switches Postamble
4–Profile Card.
1
4-6
2 Disabled
Disabled
Enabled
Enabled
MS-3000 Dual Head Decoder User’s Manual
Page 79
Profile Card Configuration Mode 5: Protocol, Host Port RS-422 = On
Mode Switches
= Off Data Switches Protocol
RS-422
123
4 Point-to-Point
Disabled
Point-to-Point with RTS/CTS
Enabled
Point-to-Point with XON/XOFF Point-to-Point with RTS/CTS & XON/XOFF Polling Mode D Multidrop User Defined User Defined Multidrop Mode 6: Aux Port Mode Switches
= On = Off
4–Profile Card.
Data Switches Aux port mode:
12 Disabled Transparent Half Duplex Full Duplex
MS-3000 Dual Head Decoder User’s Manual
4-7
Page 80
Chapter 4
Profile Card Configuration
Operations Settings Mode 7: Triggering Mode, End of Read Cycle Mode Switches
= On = Off
Triggering Mode
Data Switches End of Read Cycle
123
45 Continuous Read
Timeout
Continuous Read 1 Output
New Trigger
External Level
Timeout & New Trigger
External Edge Serial Data Serial Data & Edge Mode 8: Bar Code Output, When to Output, External Trigger Polarity, Match Code, Noread Message = On
Mode Switches
4–Profile Card.
= Off
4-8
Bar Code Output
When to Output
1
2
Data Switches Trigger Polarity
3
Edge or Level
Noread Message
4
5
Disabled
As Soon as Possible
Negative
Edge
Disabled
Enabled
End of Read Cycle
Positive
Level
Enabled