Profile Card Configuration Mode 9: System Timeout = On
Mode Switches
= Off
Since the number of profile card settings is limited to 255, system timeouts entered from the profile card can only affect a range from 0.1 seconds to 25.5 seconds, in tenths of a second. To set System Timeout, multiply the desired number of seconds for timeout by 10 and enter the result in binary format. See mode 1 for switch settings for timeout ranges from 0.1 seconds to 5 seconds. (Although not shown for mode 1, switches 7 and 8 are OFF for 1 through 50.) See “Binary Calculations” on page 4-12 for timeout ranges from 5.1 seconds to 25.5 seconds. Mode 10: Serial Trigger Character Mode Switches
= On = Off
You can define the Serial Trigger Character with an ASCII character of your choice, or you can use the samples provided below. To use other ASCII characters, see the ASCII table in appendix B for characters and their corresponding decimal values. See mode 1 for values from 1 to 50, or “ Binary Calculations” on page 4-12 for decimal values from 51 to 255. Data Switches
Sample Serial Trigger ASCII Characters
29
^]
49
1
65
A
90
Z
4–Profile Card.
ASCII Decimal Number
12345678
Mode 11: Number of Reads Before a Good Decode Mode Switches
= On = Off
The range for Number of Reads before a Good Decode is 1-31. See mode 1 for switch settings. MS-3000 Dual Head Decoder User’s Manual
4-9
Page 82
Chapter 4
Profile Card Configuration
Code Types Settings Mode 12: Code 39, Codabar, I 2 of 5, UPC, Code 128, Narrow Margins
Enabling data switches 1 through 5 will autodiscriminate for all code types. Mode Switches
= On = Off Data Switches
Code 39
Codabar
I 2 of 5
UPC
Code 128
Narrow Margins
1
2
3
4
5
6
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
User Outputs Settings Mode 13: Beeper Volume, Beeper Enable, Beeper Speed Mode Switches
= On
4–Profile Card.
= Off
Beeper Volume
Data Switches Beeper Enable
Beeper Speed
123
45
6
Level 1
Disabled
Fast
Level 2
On Good Read
Slow
Level 3
On Noread
Level 4 Level 5
4-10
MS-3000 Dual Head Decoder User’s Manual
Page 83
Profile Card Configuration Mode 14: Relay Driver, Full Screens, Good/Bad Polarity, New Master Pin, Laser On/Off, Reverse Video Mode Switches
= On = Off
Relay Full Driver Usage Screens
Data Switches Data Line Data Line Polarity Usage
Laser On/Off
Reverse Video
1
3
5
6
2
4
Good Read
Disabled
Negative
Disabled
Disabled
Disabled
Noread
Enabled
Positive
Enabled
Enabled
Enabled
4–Profile Card.
MS-3000 Dual Head Decoder User’s Manual
4-11
Page 84
Page 85
Chapter
5
Operational Commands Chapter Contents Summary of Operational Commands ..................................................5-2 Program Management Commands .....................................................5-3 Device Control Commands .................................................................5-3 Code Type Commands .......................................................................5-4 Counter Commands ............................................................................5-4 Test Commands ..................................................................................5-5 Status Commands ..............................................................................5-5
This chapter describes of all serial operational commands and their functions. See A-1, “Summary of Operational Commands ,” on page A-2 for quick reference. On-line serial operational commands are sent from the host to the decoder to carry out routine operations “on the fly” as distinguished from serial configuration commands which are generally used in initial setup. 1 Operational commands are preceded by a < left angle bracket symbol (unless redefined by Command Start Character command) and followed by a > right angle bracket symbol. 2
MS-3000 Dual Head Decoder User’s Manual
5-1
5–Operations
1. The decoder will only recognize a <D> serial command (Enter Menu Configuration Program) from an auxiliary terminal. 2. Command start character by default is a left angle bracket, <. It may be redefined by menu or serial command. However, the end character, a right angle bracket, >, cannot be changed.
Page 86
Chapter 5
Operational Commands
Summary of Operational Commands Table 5-1 Summary of Operational Commands
Command Type Program Management
Device Control
Code Types
Counters
Test
5–Operations
Status
Command
Result
<A>
Software Reset (does not save for power-on)
<D>
Enter Configuration Mode
<Z>
Save Configuration for Power-on
<Bdata>
Echo Data to Aux Monitor
<H>
Enable Laser Scanning
<I>
Disable Laser Scanning
<L>
Host Relay Driver
<P>
Autodiscriminate All Codes
<Q>
Enable Code 39 Only*
<R>
Enable Codabar Only*
<S>
Enable I 2 Of 5 Only*
<N>
Noread Counter
<O>
Noread Counter Reset
<T>
Trigger Counter
<U>
Trigger Counter Reset
<V>
Good Read Counter
<W>
Good Read Counter Reset
<C>
Enter Read Rate Test
<m>
Enter Scan Rate Test
<J>
Exit Read Rate or Scan Rate Test
<#>
Display Software Part Number
<!>
Display Checksum of EPROM
* Can also be accomplished in configuration menu and serial configuration command.
5-2
MS-3000 Dual Head Decoder User’s Manual
Page 87
Operational Commands
Program Management Commands <A> Software Reset. Initializes all serial <A> Initialize configuration commands in RAM and resets all counters and operating parameters. RAM Changes for Baud Rate, Stop Bits, Code ROM NOVRAM Length, etc., do not take effect until this command is sent. Note: Software Reset will cause the numeric counters in use to lose their count; record all data that you wish to save prior to sending this command. <D> Enter Configuration Mode. Enters the menu configuration program. See Chapter 2, “Menu Configuration.”1 <Z> Save Configuration for Power-on. Initialize <Z> Saves the current configuration to nonvolatile memory for availability on power-on. RAM The values of numeric counters are not ROM NOVRAM saved by this command. Note: The <Z> Save Configuration command can be executed 10,000 times. In normal usage this will exceed the life of the decoder. If frequent changes to the operating parameters are required, the <Z> command should be used only when the current configuration has been changed and the changes are to be permanent.
Device Control Commands
1. The <D> command is the only serial command that the MS-3000 decoder will recognize from an auxiliary terminal. MS-3000 Dual Head Decoder User’s Manual
5-3
5–Operations
<Bdata> Echo Data to Aux Monitor. Echoes data from host to auxiliary monitor (see Appendix I, “Auxiliary Monitor,” on page A-18 for more detail). <H> Enable Laser Scanning. Allows decoding to take place. The laser remains ON unless both of the following conditions are true: 1. The decoder is enabled for a triggered mode and 2. Laser On/Off option is enabled. <I> Disable Laser Scanning. Laser remains off while this command is in effect. This feature is useful during extended periods of time when no bar code labels are being scanned. Disabling laser scanning will not affect any downloaded commands to the decoder. The decoder remains active during this period. <L> Host Relay Driver. Allows you to send a pulse (at any time regardless of Match Code or Relay Driver status) to pin 2 of the trigger connector.
Page 88
Chapter 5
Operational Commands
Code Type Commands <P> Autodiscriminate All Codes. Enables the decoder to decode all available bar code types without changing decoder configuration settings. Note: For maximum scanning speed, enable only those bar code symbologies used in the application. <Q> Enable Code 39 Only. Allows only Code 39 labels to be read. <R> Enable Codabar Only. Allows only Codabar labels to be read. <S> Enable I 2 of 5 Only. Allows only Interleaved 2 of 5 labels to be read.
Counter Commands
5–Operations
The Xs in all counter commands denote a numeric value from 00000 to 65,535. After reaching the maximum numeric limit of 65,535, you will receive an error message and the counter will automatically rollover and start counting again at 00000. To obtain the cumulative total of counts after the rollover has occurred, add 65,536 per each rollover (the decoder does not keep track of the number of rollovers) to the current count. Note: You will lose all counter values if power to the decoder is cycled, when sending the <A> command, or upon entering and exiting configuration setup menus. Note: If you activate the counter command during a read cycle, the decoder will not output the count until the read cycle ends. <N> Noread Counter. The message N/XXXXX displays the total number of noreads that have occurred since power-on or the last Noread Counter Reset command. <O> Noread Counter Reset. Sets Noread Counter to 00000. <T> Trigger Counter. The message T/XXXXX displays the total number of triggers since power-on or the last Trigger Counter Reset command. <U> Trigger Counter Reset. Sets the trigger counter to 00000. <V> Match Counter (or Good Read Counter). The message V/XXXXX displays the total number of good reads matching the master label since power-on or the last Match Counter Reset command. This counter is always enabled, but will only work as a match count when Match Code option is enabled. If the Match Code option is not enabled, this counter adds the number of good reads, or decodes. This count can be requested at any time. 1 <W> Match Counter Reset. Sets the Match Counter to 00000.
1. Can also be used as a good read counter when Match Code is not enabled.
5-4
MS-3000 Dual Head Decoder User’s Manual
Page 89
Operational Commands <X> Mismatch Counter. The message X/XXXXX displays the number of labels successfully read that do not match the master label since power-on or the last Mismatch Counter command. <Y> Mismatch Counter Reset. Sets the Mismatch Counter to zero.
Test Commands <C> Enter Read Rate Test. Instructs the 100 %012345 decoder to output the percentage of scans 100 %012345 decoded. The read rate can vary dramati100 %012345 cally due to the angle and location of the 100 %012345 label in relation to the scan beam. This test Read Rate is very useful in aligning and positioning Percentage the scan head during installation. Label Data <m> Enter Scan Rate Test. Displays the current number of scans per second produced by the spinning mirror. <J> Exit Read Rate or Scan Rate Test. Ends the read rate test or scan rate test and returns to read or ready mode.
Status Commands <#> Display Software Part Number. Displays software part number. <!> Display Checksum of EPROM. Displays a four-digit hex number (corresponding to a given firmware version) used to verify a decoder’s EPROM.
5–Operations
MS-3000 Dual Head Decoder User’s Manual
5-5
Page 90
Chapter5 Operational Commands
2) i= ie} =] © pa o 2. 2 ie)
MS-3000 Dual Head Decoder User’s Manual