Chapter 2
Menu Configuration
Scanner #1 and #2 Setup Note: “Scanner #1 Setup” and “Scanner #2 Setup” refer to scan head #1 and scan head #2 respectively and apply to both Independent and Sequenced modes.
2–Menu Config.
End of Read Cycle Default: Timeout Options: Timeout, New Trigger, Timeout & New Trigger Allows you to choose the conditions that will end the read cycle for scan head #1. The read cycle is the duration of time in which the decoder can receive and process label data when in a triggering mode (External or Serial). Note: When operating in Continuous or Continuous 1, the decoder is always in the read cycle. Selecting:
2-18
Has this effect:
Timeout
Can end the read cycle after a specified period of time, and if no label has been read, causes a noread message, if enabled, to be transmitted. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout ends the read cycle. With External Level enabled, the read cycle does not end until the falling edge trigger occurs, and the next read cycle does not begin until the next rising edge trigger. With Continuous Read 1 Output enabled, a timeout initiates a new read cycle and allows the same label to be read again.
New Trigger
Ends the read cycle at the occurrence of a new trigger event, and if no label has been read, causes a noread message, if enabled, to be transmitted at the occurrence of the new trigger event. With either External Edge, Serial Data, or Serial Data & Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. With External Level enabled, a falling edge trigger ends a read cycle. However, the next read cycle does not begin until the occurrence of the next rising edge trigger.
Timeout & New Trigger
Ends the read cycle upon a timeout or a new trigger, and if no label has been read, sends a noread message (if enabled). With either Edge, Serial, or Serial & Edge enabled, a timeout, an edge or serial trigger, whichever comes first, ends the read cycle. An edge or serial trigger also initiates a new read cycle. With Level enabled, the read cycle does not end until a falling edge occurs. The next read cycle does not begin until the next rising edge trigger.
MS-3000 Dual Head Decoder User’s Manual
Page 43
Operations Menu Timeout (in 10 ms incs) Default: 100 (one second). Corresponds to 1000 ms displayed in the menu. Options: 0 to 65535. Divide the number entered on the command line by 100 for time in seconds. Note: Timeout or Timeout & New Trigger under End of Read Cycle (page 2-18)
must be enabled for Timeout (in 10 ms incs) to take effect.
1. For example, assigning an upper case D would nullify the <D> (Enter Menu Configuration) command. For a list of operational commands used by the decoder, see table 5-1 on page 5-2. MS-3000 Dual Head Decoder User’s Manual
2-19
2–Menu Config.
Allows you to define the duration of the timeout period for scan head #1. Serial Trigger Character Scanner #1 Default: ^]. Corresponds to <GS> displayed in the menu. Scanner #2 Default: ^^. Corresponds to <RS> displayed in the menu. Options: Any single ASCII character , including control characters, except a NUL (00H), an existing host command character, 1 or an on-line protocol character. Allows you to define a single ASCII character as the host serial trigger character that initiates the read cycle. The serial trigger is an on-line host command and requires the same command format as all host commands (that is, to be entered within the < > brackets). Control characters entered on the command line are displayed in the menu as mnemonic characters. See and Table A-2, “ASCII Table with Control Characters,” on page A-3 Note: Serial Data (page 2-14) or Serial Data & Edge (page 2-14) must be enabled for Serial Trigger Character to take effect. “N/A” is displayed in the menu when all other triggering modes are enabled. Noread Message Default: NOREAD Options: Up to seven ASCII characters (except a NUL). Allows you to define any combination of ASCII characters (except a NUL) up to seven characters as the noread message. The noread message, if enabled and if no bar code label has been decoded, will be transmitted to the host at a timeout or the end of a read cycle. Noread Message (enable/disable) Default: Enabled Options: Enabled, Disabled Note: If Noread Output is enabled, the noread message will only output if Bar Code Output is also enabled.
Page 44
Chapter 2
Menu Configuration Scanner Identifier Scanner #1 Default: 1/ Scanner #2 Default: 2/ Options: One or two ASCII characters . Allows you to define an identifier which, when enabled, will be appended to the front of each good read or noread. For example, a decoded label such as 100678 will appear as 1/100678 if read by scan head #1 or 2/100678 if read by scan head #2.
2–Menu Config.
Note: Be certain that the character(s) has not been assigned to any other command.
Press SP to advance to Scanner Identifier [enable/disable]. Scanner Identifier [enable/disable] Default: Enabled Options: Enabled, Disabled
Bar Code Output Default: Enabled Options: Enabled, Disabled Allows you to choose whether or not to send label data (or noreads) to the host. When disabled, a label is decoded and the read cycle transpires as usual, but neither label data nor the noread message is transmitted to the host. All decoder counters are updated, and the number of good reads or noreads can be obtained via operational commands.
When to Output Default: As Soon As Possible Options: As Soon As Possible, End of Read Cycle Allows you to choose when bar code data is sent to the host. Selecting: Has this effect: As Soon As Possible
Causes bar code data (good reads) to be transmitted immediately upon a good decode.
End of Read Cycle
Causes bar code data output to be delayed until the end of the read cycle.
Number of Reads Before a Good Decode Default: 1 Options: 1 to 31 Allows you to select the number of good reads (from 1 to 31) required per label before a good decode output. Note: Be sure to set the value within the determined scan rate for the scanning setup so that the decoder is capable of scanning a label the required number of times. 2-20
MS-3000 Dual Head Decoder User’s Manual
Page 45
Code Types Menu
Code Types Menu The Code Types menu allows you to choose among five bar code types and define their parameters. Code Types
– Bold text represents default settings.
Scanner #1 Narrow Margins
Status
Status – Enabled
– Disabled
– Enabled
Check Digit – Disabled – Enabled
Check Digit Output
Code Length
Large Interchar Fixed Code Length Gap
– Disabled
– Disabled
– Enabled
– Enabled
– 10
– Disabled
– User Definable
Fixed Code Length
Code Length
(1 to 31)
– Enabled
Codabar Status – Disabled – Enabled
Start & Stop Match
Start & Stop Output
– Enabled
– Enabled
Large Interchar Gap – Disabled
– Disabled
– Disabled
– Enabled
– 10
– User
– Disabled
Definable (1 to 31)
– Enabled
I 2 of 5 Status – Disabled – Enabled
Check Digit – Disabled – Enabled
– Disabled – Enabled
– Disabled
Code Length #1 – 10
– User Definable
(even, 0 to 30)
– Enabled
UPC Status
Check Digit Output
EAN
Supplementals
– Disabled – Enabled
– Disabled – Enabled
– Required
Separator – Enabled
– Disabled
– Disabled – Enabled
Fixed Code Length – Disabled
– 6
– User Definable
(even, 0 to 30)
Separator (character) – , (comma)
– User Definable
(ASCII char.)
Code 128 Status
Code Length #2
Code Length – 10
– Enabled
– User Definable (1 to 31)
Scanner #2 Code 39 – Enabled
– Disabled
Codabar
I 2 of 5
– Disabled – Enabled
– Disabled – Enabled
UPC – Disabled – Enabled
Code 128 – Disabled – Enabled
Figure 2-6 Code Types Menu Structure
MS-3000 Dual Head Decoder User’s Manual
2-21
2–Menu Config.
– Disabled
Code 39
Page 46
Chapter 2
Menu Configuration Note: Options listed in the command line do not always appear in the same order as those posted in the first column of the menu.
Options can be defined for any bar code type whether or not the bar code itself is enabled at the time.
Scanner #1 Note: All individual code fields (Check Digit, Code Length, etc.) for both scan head #1 and scan head #2 are configured in the scanner #1 command line.
2–Menu Config.
Narrow Margins Default: Disabled Options: Disabled, Enabled When enabled, the decoder can read labels with quiet zones as small as five times the width of the narrow bar element. When disabled, the relative width of quiet zones to the narrow bar element is 10 to 1. A quiet zone is the minimum space at the leading and trailing ends of a label. when Narrow Margins is enabled.
Code 39 Status Default: Enabled Options: Enabled, Disabled Check Digit Default: Disabled Options: Disabled, Enabled Code 39 is self-checking and does not normally require a check digit. However, for additional data integrity, a Modulus 43 check digit can be added to the bar code message. With Check Digit and an External or Serial trigger option enabled (see “System Trigger Type” on page 2-15), an invalid check digit calculation will cause a noread message to be transmitted at the end of the read cycle. Check Digit Output Default: Disabled Options: Disabled, Enabled When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit. Large Intercharacter Gap Default: Disabled Options: Disabled, Enabled 2-22
MS-3000 Dual Head Decoder User’s Manual
Page 47
Code Types Menu
Codabar Status Default: Disabled Options: Disabled, Enabled Start & Stop Match Default: Enabled Options: Enabled, Disabled Requires the Codabar start and stop characters (a, b, c, or d) to match before a valid read can occur. Start & Stop Output Default: Enabled Options: Enabled, Disabled Allows the start and stop characters to be transmitted with bar code data. Large Intercharacter Gap Default: Disabled Options: Disabled, Enabled When enabled, the decoder can read labels with gaps between bar code characters exceeding three times the narrow element width. Fixed Code Length Default: Disabled Options: Disabled, Enabled When enabled, increases data integrity by ensuring that only one label length will be accepted. MS-3000 Dual Head Decoder User’s Manual
2-23
2–Menu Config.
When enabled, the decoder can read labels with gaps between bar code characters exceeding three times the narrow element width. Fixed Code Length Default: Disabled Options: Disabled, Enabled When enabled, increases data integrity by ensuring that only one label length will be accepted. Code Length Default: 10 Options: 1 to 31 Note: Fixed Code Length must be enabled for Code Length to take effect. Allows you to specify the exact number of characters that the decoder will recognize (this does not include start and stop). The decoder will ignore any code not having the specified length.
Page 48
Chapter 2
Menu Configuration Code Length Default: 10 Options: 1 to 31 Note: Fixed Code Length must be enabled for Code Length to take effect. Allows you to specify the exact number of characters that the decoder will recognize (this does not include start and stop). The decoder will ignore any code not having the specified length.
2–Menu Config.
Interleaved 2 of 5 Status Default: Disabled Options: Disabled, Enabled Note: Because I 2 of 5 is a continuous code, it is prone to substitution errors. Hence, a code length must be defined and a bar code label containing an even number of digits must be used. It is also recommended that a Modulus 10 check digit be used to ensure the best possible data integrity.
Check Digit Default: Disabled Options: Disabled, Enabled I 2 of 5 uses a Modulus 10 check digit. Check Digit Output Default: Disabled Options: Disabled, Enabled When enabled, the check digit character is sent along with the label data. When disabled, label data is sent without the check digit. Code Length #1 Default: 10 Options: 0 to 30 (Even numbers only. If you enter an odd number, the decoder will use the next lower number.) Note: With I 2 of 5, two code lengths can be defined. When using only one label length in an application, we recommend setting Code Length #2 to 0 to ensure data integrity. If a check digit is used, it must be included in the code length count.
Code Length #2 Default: 6 Options: 0 to 30 (Even numbers only. If you enter an odd number, the decoder will use the next lower number.)
2-24
MS-3000 Dual Head Decoder User’s Manual
Page 49
Code Types Menu
UPC the supplemental code is between 5:1 and 10:1 (in relation to narrow-bar-width).
When set to Enabled, the decoder can read supplemental bar code data that has been appended to the standard UPC or EAN codes and treats that data as a separate label. When set to Required, the decoder treats the supplemental data and the bar code label as a single label. Supplemental data must be found or a noread will result. Separator Default: Enabled Options: Enabled, Disabled When enabled, the decoder inserts a Separator character between the standard UPC or EAN code and the supplemental code. Separator (character) Default: , (comma) Options: Any ASCII character. Allows you to define the separator character between the standard UPC or EAN code and the supplemental code.
MS-3000 Dual Head Decoder User’s Manual
2-25
2–Menu Config.
Status Default: Disabled Options: Disabled, Enabled When enabled, the decoder will read UPC version A and UPC version E only. EAN Default: Disabled Options: Disabled, Enabled Note: UPC must be enabled for EAN to take effect. When enabled, the decoder can read UPC version A, UPC version E, EAN 13, and EAN 8. It can also append a leading zero to UPC version A label information and transmit 13 digits. If you do not want to transmit 13 digits when reading UPC version A labels, disable EAN. Supplementals Default: Disabled Options: Disabled, Enabled, Required Note: Narrow Margins must be enabled if the gap between the standard code and
Page 50
Chapter 2
Menu Configuration
Code 128
2–Menu Config.
Status Default: Disabled Options: Disabled, Enabled Fixed Code Length Default: Disabled Options: Disabled, Enabled Allows you to increase data integrity by ensuring that only one label length will be accepted. Code Length Default: 10 Options: 1 to 31 Note: Fixed Code Length must be enabled for Code Length to take effect. Allows you to specify the exact number of characters that the decoder will recognize. The decoder will ignore any code not having the specified length.
Scanner #2 Note: All individual code fields (Check Digit, Code Length, etc.) for both scan head #1 and scan head #2 are configured in the scanner # 1 command line.
Code 39 Default: Enabled Options: Enabled, Disabled Codabar Default: Disabled Options: Disabled, Enabled I 2 of 5 Default: Disabled Options: Disabled, Enabled UPC Default: Disabled Options: Disabled, Enabled Code 128 Default: Disabled Options: Disabled, Enabled
2-26