Page 31

Communications Menu Has this effect:

Point-to-Point with XON/XOFF (Transmitter On/Off)

Used only with RS-232 or RS-422. This selection enables the host to send a single byte transmission command of start (XON) or stop (XOFF). If an XOFF has been received from the host, data will not be sent to the host until the host sends an XON. During the XOFF phase, the host is free to carry on other chores and accept data from other devices.

Point-to-Point with RTS/CTS and XON/XOFF

Used only with RS-232. It is a combination of Point-toPoint with RTS/CTS and Point-to-Point with XON/ XOFF.

Polling Mode D

Like Point-to-Point, Polling Mode D requires a separate connection to the host but unlike Point-toPoint, it requires the device to have an address and to wait for a poll from the host before sending data. When in Polling Mode D, an address 1 is automatically displayed on the configuration screen. However, during transmission, a 1C hex poll address (FS) and a 1D hex select address (GS) are substituted for the 1.

Multidropa

Similar to Polling Mode D except that a unique poll

Note: Decoders intend- address and select address are required for each multidrop device, and only one host port connection is ed to link up to a MS-5000 multidrop con- needed for up to 50 devices. (For Multidrop poll and select characters, see Table A-8, “Multidrop Address centrator can only be configured in standard Characters,” on page A-25.) Multidrop protocol. Requires a concentrator or controller using RS-485 communications. When Multidrop is selected, the Hint: Attach a tag to each decoder to identify protocol characters for RES, REQ, etc. are assigned automatically. (See “Appendix I, Auxiliary Monitor” its multidrop address. on page A-18 for poll and select sequences.)

MS-3000 Dual Head Decoder User’s Manual

2-7

2–Menu Config.

Selecting:

Page 32

Chapter 2

Menu Configuration Selecting:

Has this effect:

User Defined

Used only with RS-232 or RS-422. ASCII characters can be assigned as an address and as protocol commands (RES, REQ, EOT, STX, ETX, ACK, and NAK). User Defined is necessary when a new protocol must be defined to match a specific host protocol. When User Defined is selected, the displayed protocol commands match those of the previously selected protocol. User Defined is considered to be in a polled mode only if an address has been assigned. The address can be any ASCII character from the ASCII in appendix B, except NUL.b

2–Menu Config.

Note: A specific ASCII character must not be assigned more than once.

User Defined Multidrop Note: A specific ASCII character must not be assigned more than once.

Used when connecting to a concentrator or other device that does not match standard Multidrop protocol. Any single character (01 hex to 7E hex) in the ASCII table can be assigned as the address character. The character chosen is used as the poll character and the subsequent ASCII character becomes the select character. For example, if a ^A (01 hex) is selected as the address, ^B (02 hex) becomes the select address that the host will use in sending host select commands. (See Table A-8, “Multidrop Address Characters,” on page A-25.)

a. Once the decoder is configured for Multidrop, a profile card, a terminal connected to the auxiliary RS-232 pins, or a default procedure must be used to access the configuration menus again (although serial commands will continue to function). b. For example a simple ACK/NAK protocol can be developed by first selecting Point-to-Point, then User Defined, and then assigning characters to ACK and NAK commands. First scroll to the following command: HOST PROTOCOL --> PROTOCOL --> USER DEFINED--> ACK = --> Enter a ^F by holding down the Control key while pressing the F key, and then press CR to see the following: HOST PROTOCOL --> PROTOCOL --> USER DEFINED --> ACK = ^F The mnemonics ACK and NAK replace the default NULs in the menu.

Note: Definitions of commands in User Defined and User Defined Multidrop must be duplicated in host applications to enable poll and select sequences to execute correctly during transmission.

Typically, parameters in User Defined Multidrop are defined by first enabling Multidrop, then enabling User Defined Multidrop. This pre-loads Multidrop characters into the parameters. You then change individual characters to match the host or other requirements.

2-8

MS-3000 Dual Head Decoder User’s Manual

Page 33

Communications Menu

Preamble Default:

Preamble (enable/disable) Default: Disabled Options: Disabled, Enabled (within any protocol) Allows you to enable or disable the preamble character(s).

Postamble Default:

^M^J. Corresponds to <CR><LF> (carriage return/line feed) displayed in the menu. Options: Any ASCII character, including control characters. Control characters entered on the command line are displayed in the menu as mnemonic characters. See “ Defining Special Characters ,” on page 2-4 and Table A-2, “ ASCII Table with Control Characters ,” on page A-3. Allows you to define a one or two character data string that can be added after the decoded message. If User Defined, Polling Mode D, or Multidrop is enabled, the Postamble and Preamble characters are transmitted within the STX and ETX data block.

Postamble (enable/disable) Default: Disabled Options: Disabled, Enabled (within any protocol)

Longitudinal Redundancy Check Default: Disabled (in unpolled mode), Enabled (in polled mode) Options: Disabled, Enabled

MS-3000 Dual Head Decoder User’s Manual

2-9

2–Menu Config.

^M (and a null). Corresponds to <CR><NUL> (carriage return/null) displayed in the menu. Options: Any ASCII character, including control characters. Control characters entered on the command line are displayed in the menu as mnemonic characters. See “ Defining Special Characters ,” on page 2-4 and Table A-2, “ ASCII Table with Control Characters ,” on page A-3. Allows you to define a one or two character data string that can be added to the front of the decoded data. For example, a carriage return and line feed would display each decoded message on its own line. If User Defined, Polling Mode D, or Multidrop is enabled, the Preamble and Postamble characters are transmitted within the STX and ETX data block.

Page 34

Chapter 2

Menu Configuration An error-checking routine that verifies the accuracy of transmissions. It is the exclusive OR of all characters following the SOM (start of message) up to and including the EOM (end of message).

Response Timeout

2–Menu Config.

Default: 12 ms Options: 0 to 65,000 ms. A zero (0) causes an indefinite wait. Allows you to set the time the decoder will wait before timing out if ACK, NAK, and ETX are enabled and a host response is expected.

Intercharacter Delay Default: 0. Corresponds to 0 ms displayed in the menu. Options: 0 to 255. A zero (0) causes no delay between characters. Allows you to set the time interval in milliseconds between individual characters transmitted from the decoder to the host. A high setting will significantly slow down communications. For example, a 200 setting will result in a 1/5 second delay between each character that is transmitted.

Host Port Parameters Allows you to set parameters for host port communications.

Baud Rate Default: 9600 Options: 9600, 19.2K, 38.4K, 600, 1200, 2400, 4800 Allows you to select the number of bits transmitted per second Note: Due to timing considerations, polled modes require 2400 baud or faster.

Parity Default: Even Options: Even, Odd, None Allows you to select an error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd.

Stop Bits Default: One Options: One, Two Allows you to select the last one or two bits in each character to indicate the end of the character.

2-10

MS-3000 Dual Head Decoder User’s Manual

Page 35

Communications Menu

Data Bits Default: Seven Options: Seven, Eight Allows you to establish the total number of data bits in each character.

RS-422

Aux Port Parameters Allows you to set communications settings between the decoder and an auxiliary monitor. An auxiliary monitor can be used to configure the menus, send data to the host, and display data transmissions originating from the host or decoder. Note: Aux Port operates in RS-232 only. See Appendix H, “Interface Standards,” on page A-17 for a full description of auxiliary port options.

Aux Mode (auxiliary mode) Default: Disabled Options: Disabled, Transparent, Half Duplex, Full Duplex Allows you to select a communications mode for auxiliary operations (see Appendix I, “Auxiliary Monitor,” on page A-18).

Other Aux Port Parameters Allows you to set other Aux Port parameters - Baud Rate, Parity, Stop Bits, and Data Bits which are identical to the host port parameters and are changed in the same manner (see page 2-10). Note: The Aux Port baud rate should never exceed Host Port baud rate or auxiliary port data could be lost.

MS-3000 Dual Head Decoder User’s Manual

2-11

2–Menu Config.

Default: Disabled Options: Disabled, Enabled Note: Used only in Point-to-Point protocol only, and not with RTS/CTS. Whenever RS-422 is disabled, RS-232 is enabled in the background. However, when Multidrop is enabled, the functioning protocol is RS-485 regardless of the displayed status of RS-422 in the menus. Before enabling RS-422, first double-check that Multidrop is not enabled. (See “ Protocol,” on page 2-6.) (See Appendix H, “Interface Standards,” on page A-17 for additional information on RS-422.)

Page 36

Chapter 2

Menu Configuration

Operations Menu To help visualize the menu’s organization and to locate the page number where each topic is described, see figure 2-3 Operations

– Bold text represents default settings.

Independent Mode

Scanner #1

– Disabled

2–Menu Config.

– Enabled

– Continuous 1 – External

Sequenced Mode

System Trigger Type

– Disabled – Enabled

– External &

Serial – External – Serial

Level or Edge Trigger Trigger Polarity Scanner #1 Setup End of Read Timeout in Cycle 10ms incr = 100 – Timeout

Scanner #2

– Continuous

Number of Labels

- Serial - External & Serial

Number of Passes – One Each

– One

– Multiple

– Two

– External – Serial

– External & Serial

System Timeout Ends Read – Disabled

System Timeout in 10ms incr. = 600

– Enabled

Level

Edge

Positive

Negative

Trigger Char = ^]

Noread Message = NOREAD

Noread Message – Disabled

– New Trigger

Scanner Identifier = 1/

Scanner Identifier

Scanner Identifier = 2/

Scanner Identifier

– Enabled

– Trigger or

– Disabled – Enabled

Trigger

Scanner #2 Setup End of Read Cycle – New Trigger

Timeout in 10ms incr = 100

Trigger Char = ^^

Noread Message = NOREAD

Noread Message

– Timeout or

– Disabled – Enabled

New Trigger – Timeout

Barcode Output When to Output

Disabled As Soon As Possible

Enabled End of Read Cycle

# of Reads Before a Good Decode = 1

Figure 2-3 Operations Menu Structure

2-12

MS-3000 Dual Head Decoder User’s Manual

– Disabled – Enabled

Page 37

Operations Menu

Independent Mode Mode Default: Enabled Options: Enabled, Disabled Note: Disabling Independent mode enables Sequenced mode.

Selecting:

Has this effect:

Continuous

Trigger input options are disabled and the decoder is always in the read cycle. Bar code data is decoded, and label information is transmitted repeatedly, as long as the label is in the range of the scan head. When To Output options have no affect on Continuous Read. Continuous Read is useful in testing label or scan head functions.

Note: If Continuous Read is enabled with Match Code, the decoder defaults to Continuous Read 1 Output mode.

MS-3000 Dual Head Decoder User’s Manual

2-13

2–Menu Config.

When enabled, each scan head has its own trigger and its own set of operating parameters (End of Read Cycle, Timeout, Noread message, etc.) that can be configured independently. For example, scan head #1 might be configured for Continuous, while scan head #2 could be configured for External and Level (trigger) with Timeout enabled. In Independent mode both scan heads can be configured in a triggering mode (External or Serial), but only scan head #1 can be set to a non-triggering mode (Continuous or Continuous One). Scanner #1 Triggering Mode Default: Continuous Options: Continuous, Continuous 1, External, Serial, Serial & External Allows you to choose between five modes relating to the read cycle. (See “System Trigger Type” on page 2-15.)

Page 38

Chapter 2

Menu Configuration Selecting:

Has this effect:

Continuous 1a

Label data is immediately transmitted with Timeout set to End Of Read Cycle. If the label doesn't change, the decoder will repeat the output at the end of each subsequent timeout period. For example, if Timeout is set to one second, the decoder will output the label data immediately and repeat the output at intervals of one second for as long as the label continued to be scanned. With Timeout disabled (that is, End Of Read Cycle set to New Trigger), the decoder outputs the current label data immediately but only once. A new label appearing at any time in the scan range will produce a new read output provided the new label is not identical to the previous label.

2–Menu Config.

Note: Enabling Continuous Read 1 Output when Number of Labels (page 2-15) is set to any number greater than one will cause Number of Labels to default back to one.

External

A signal from an external object detector will trigger a read cycle.

Serial

A pre-defined serial ASCII character from the host will trigger a read cycle.

Serial & External

Either an external trigger or a serial command will trigger a read cycle.

a. Continuous 1 will allow an output regardless of how Good Decode Read is set.

Scanner #2 Triggering Mode Default: External Options: External, Serial, Serial & External Allows you to choose between the three read cycle triggering modes. (See “System Trigger Type” on page 2-15.) (See “Scanner #1 Triggering Mode ” on page 2-13 for explanation of options.)

2-14

MS-3000 Dual Head Decoder User’s Manual

Page 39

Operations Menu

Sequenced Mode

Note: You can change back to Independent mode by either disabling Sequenced or pressing B to scroll back to Independent prompt and enabling Independent.

System Trigger Type Default: External & Serial Options: External & Serial, External, Serial Allows you to select the trigger type that will control the sequenced read cycle. (See “Scanner #1,” on page 2-22 for explanation of options.) System Trigger Type is not specified by default but must be selected when Sequenced Mode is enabled. Otherwise the following prompt will be displayed to the right of System Trigger in the menu whenever the screen is refreshed: * PLEASE SPECIFY *

Number of Labels Default: One is enabled. Options: One, Two. If One is selected, the read cycle will end after a single label has been read. If Two is selected, the read cycle will not end until the decoder has read a label at each scan head or a timeout occurs. Number of Passes Default: One Each Options: One Each, Multiple. Note: If Number of Passes is set to Multiple, System Timeout Ends Read must be enabled. If Multiple is enabled and System Timeout is disabled, the cycle will repeat itself indefinitely until a good read or new trigger occurs.

When One Each is enabled, the decoder will check for a label at each scan head only once before timing out. For example, if Timeout for both scan heads has been set to 100 (one second), the decoder will spend one second searching for a label at scan head #1 and another second searching at

MS-3000 Dual Head Decoder User’s Manual

2-15

2–Menu Config.

Mode Default: Disabled Options: Disabled, Enabled When enabled, a single system trigger activates the read cycle for both scan heads. The decoder can be configured to make one or more sequential passes, checking first one and then the other scan head for data. Each scan head retains its individual timeout but the system timeout is dominant.

Page 40

Chapter 2

Menu Configuration

2–Menu Config.

scan head #2. If it fails to find a label during those two seconds, the read cycle ends. Note: Do not confuse individual scan head timeouts with System Timeout. Individual scan head timeouts are set under Scanner #1 and #2 Setup (see page 2-18). A System Timeout, on the other hand, applies to both scan heads and only when Number of Passes is set to Multiple. When Multiple is enabled, System Timeout determines the overall duration of the read cycle. The decoder makes multiple passes, alternating between scan head #1 and scan head #2 until the read cycle is ended by a good read, a system timeout, or a new trigger. For example, if each scan head is set to timeout after one second and System Timeout is set to six seconds, the decoder will alternate between the two scan heads, one second for each, until a label is read, a new trigger occurs, or the system times out at six seconds. Note: If Multiple is enabled and System Timeout is not enabled, the cycle will repeat itself indefinitely until a good read or new trigger occurs. System Timeout Ends Read Default: Disabled Options: Disabled, Enabled System Timeout Default: 600 (six seconds) Options: 0 to 65535 Allows you to set the total elapsed time the decoder will search for a label at both scan heads when Number of Passes is set to Multiple. When a system timeout occurs, no further individual scan head timeouts will occur and the read cycle ends. Note: The following operational menu parameters (“Level or Edge Trigger” through “# of Reads before a Good Decode”) can be accessed from either Independent or Sequenced modes.

2-16

MS-3000 Dual Head Decoder User’s Manual