The text of a manual · part 4 of 4
ScanPal 2 Portable Data Collection Terminal User manual, pages 28 to 36
Pages 28 to 36 of 36
The original document is the PDF (782 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic ScanPal 2
Page 28
• KBD Tests the keypad keys. FN Pressing a key displays its value on the screen. The aaaa function key must be used in combination with a numeric key (1 to 9). ESC Press the aaaa key to stop the test.
6. Download • RS232 Downloads a user program (*.SHX) into the ScanPall2 Portable Terminal, via the RS232 port (cable or download cradle). On the PC (under Windows), use DownLoad.EXE. The speed can go up to 115,200 bps. • IR (High-speed infrared) Downloads a user program (*.SHX) into the ScanPall2 Portable Terminal, via the high-speed infrared transceiver. On the PC (under Windows), use IRLoad.EXE. The speed can go up to 115,200 bps. • IrDA Downloads a user program (*.SHX) into the ScanPall2 Portable Terminal, via the standard IrDA infrared. On the PC (under Windows), use DownLoad.EXE. The speed can go up to 115,200 bps. 7. Version Displays the following information: Hardware version number .........................(H/W) Serial number............................................ (S/N) Manufacturing date ...................................(M/D) Kernel version number ..............................(KNL) Library version number.............................. (LIB) User program ........................................... (USR)
22
Page 29
5.4.
Kernel Mode Turn off the ScanPall2 Portable Terminal, and then simultaneously press the aaaaal, aaaaal 7 ABC 9 GHI and aaaa keys to enter System mode; next turn off the ScanPall2 Portable Terminal, and 1 STU aaaaal then simultaneously press the aaaaal, 7 ABC and aaaa keys to enter Kernel mode. Kernel mode offers the following operations:
1 2 3 4
Kernel Menu Program Download Update Kernel Test & Calibrate Version
1. Program Download Downloads a user program (*.SHX) into the ScanPall2 Portable Terminal. The download procedure is identical to that described in System mode (refer to section 5.3, Download). 2. Update Kernel Updates the system kernel. Updating the kernel is sometimes necessary in order to improve the system performance, or for some other reason. This function guarantees that the latest version of the kernel is being used. The procedure for updating the kernel (KSP2-xxx.SHX) is identical to that for downloading a user program. Be careful: after updating the kernel, wait until the system has completely restarted before powering down the ScanPall2 Portable Terminal. 3. Test & Calibrate This function is intended solely for performing various tests, diagnostics and calibrations in the factory. Do not use.
23
Page 30
4. Version Displays the following information: Hardware version number .........................(H/W) Serial number............................................ (S/N) Manufacturing date ...................................(M/D) Kernel version number ..............................(KNL)
24
Page 31
5.5.
Overview R232_Read.EXE
To be defined by programming
To be defined by programming
Data
Data
Data
Application
"BASIC" program
"C" program or
DLookup.EXE
Ir_Read.EXE or directly from AG_SP2.exe or directly from AG_SP2.exe
File Application created with the application generator AG_SP2.EXE
ATX_Load.EXE
Program Module or directly from AG_SP2.EXE
ScanPal 2 off
Application generator File Application interpreter (1)
DownLoad.EXE or
IrLoad.EXE
System menu Download option
7 ABC
+ OR
9 GHI File "BASIC" program created with the "BASIC" compiler BC.EXE
SynLoad.EXE or directly from BC.EXE
+
System menu Download Basic option
"BASIC" compiler (3)
System Module File "BASIC" interpreter (2)
DownLoad.EXE or
IrLoad.EXE
System menu Download option
ScanPal 2 off
OR "C" compiler (3)
File Compiled "C" program
DownLoad.EXE or
IrLoad.EXE
1 STU
System menu Download option
+ 7 ABC
+ File
Update
Kernel
DownLoad.EXE or
IrLoad.EXE
Kernel menu Update Kernel option
Kernel Module File or or
DownLoad.EXE or
IrLoad.EXE
25
Kernel menu Program Download option
Page 32
26
Page 33
6.
Troubleshooting guide • The ScanPall2 Portable Terminal doesn’t come on after the aaaa key has been pressed. Change the batteries or recharge the battery. • The ScanPall2 Portable Terminal doesn’t come on after the batteries have been changed or the battery recharged. Check that the replaceable batteries are correctly installed in their compartment and that the compartment (or the rechargeable battery) is properly engaged in the terminal. If the problem persists, contact Technical Support. • The battery icon, indicating the charge state, is empty. Change the replaceable batteries or recharge the battery. • No transmission between the ScanPall2 Portable Terminal and the host system (PC or other), via the RS232 port (cable or download cradle). Check that the RS232 cable is correctly connected to the host system and to the ScanPall2 Portable Terminal or to the download cradle. For transmission using the download cradle, check that the ScanPall2 Portable Terminal is correctly inserted in its cradle. Check that the communication settings of the host system match those of the ScanPall2 Portable Terminal. • No transmission between the ScanPall2 Portable Terminal and the host system (PC or other), via the high-speed IR transceiver. Check that the IR transceiver is correctly connected. Check that the communication settings of the host system match those of the ScanPall2 Portable Terminal. Check that the ScanPall2 Portable Terminal is correctly positioned in the IR transceiver read area (a distance of 5 cm to 100 cm, and a maximum angle of 30°). • The keypad doesn’t work correctly. 7 ABC Turn off the ScanPall2 Portable Terminal, and then simultaneously press the aaaaal, aaaaal 9 GHI and aaaa keys to enter System mode. Select the Test KBD option and carry out the keypad key test.
If the problem persists, contact Technical Support.
27
Page 34
• The scanner doesn’t work. Check that the symbologies of the codes read are enabled. Check whether the battery icon, indicating the charge state, is empty. If this is the case, change the replaceable batteries or recharge the battery. If the problem persists, contact Technical Support.
28
Page 35
7.
Metrologic references and descriptions
Reference
Description Basic ScanPal 2 CCD kit, including:
SCANPAL 2C-B
- 1 ScanPal 2 CCD portable terminal - 2 AAA batteries - 1 RS232 cable
Advanced ScanPal 2 CCD kit, including: SCANPAL 2C-E
- 1 ScanPal 2 CCD portable terminal - 1 download/charger cradle and its power supply - 1 RS232 cable - 1 rechargeable battery
Basic ScanPal 2 Laser kit, including: SCANPAL 2L-B
- 1 ScanPal 2 Laser portable terminal - 2 AAA batteries - 1 RS232 cable
Advanced ScanPal 2 Laser kit, including: SCANPAL 2L-E
- 1 ScanPal 2 Laser portable terminal - 1 download/charger cradle and its power supply - 1 RS232 cable - 1 rechargeable battery
99-99001
Battery charger (with power supply and 1 rechargeable battery)
99-99002
Ni-MH rechargeable battery
99-99003
Screen/keyboard Wedge cable
99-99004
Protective case
99-99005
High-speed IR transceiver
99-99006
"BASIC" compiler
99-99007
"C" compiler
99-99008
Download/charger cradle (with power supply and 1 rechargeable battery)
99-99009
RS232 cable
99-99010
Cradle power supply (for the charger function only)
29
Page 36
30