Page 19
5.
Operations
Before any operation, it is advisable to make sure that the replaceable batteries are new, or that the rechargeable battery is correctly charged.
5.1.
Operations at the keypad The ScanPall2 Portable Terminal keypad consists of 20 rubber keys and one key for triggering the scanner. The functions of the special keys are as follows: Enter Confirms an entry on the keypad. BS
Back Space Deletes the characters situated to the left of the cursor.
SP
Space Inserts the space character.
Up Moves the cursor upwards.
Down Moves the cursor downwards.
Alpha
Alphabetic / Numeric toggle Makes it possible to change alternately from the alphabetic entry mode to the numeric entry mode. When the terminal is in alphabetic mode, a small icon is displayed on the screen, and each numeric key can be used to insert one of the three letters written on the key. Successive pressing of the key successively displays the three available letters. Releasing the key for one second or pressing another key confirms the letter displayed and inserts it.
13
Page 20
FN
Function This key cannot be used on its own, but in combination with a numeric key (1 to 9), in order to obtain a specific function, depending on the program loaded. FN 1 STU keys activates For example, pressing simultaneously on the aaaa and aaaaal the function #1 (up to 9 functions). FN FN Pressing simultaneously on the aaaa and aaaa, or aaaa and aaaa , keys makes it possible to adjust the screen contrast. FN Pressing simultaneously on the aaaa and aaaaal keys makes it possible to activate or de-activate the screen backlighting.
ESC
Escape Generally makes it possible to exit the current operation. Power On/Off To avoid pressing this key in error, the power on/off function is activated only when the aaaa key is held in for around 1.5 seconds.
14
Page 21
5.2.
Program Mode This is the default operating mode when the ScanPall2 Portable Terminal is powered up. It depends on the user program loaded into the Program module.
The application interpreter and its inventory application, loaded by default, displays the following main menu:
1.Collect data 2.Upload data 3.Utilities JUN 16, 13:30
(R)
00000
The counter, located in the bottom right-hand corner of the screen, displays the number of records collected. 1. Collect data Data collection starts after confirmation of the Collect data operation, using the aaaaal, key. A new screen displays the following two prompts: Item: Qty: 1 The Item (Article) prompt expects an item code, read by the scanner or entered on the keypad and confirmed by the aaaaal key. The Qty (Quantity) prompt offers, by default, a quantity of 1, which can be modified by entering on the keypad the new quantity desired. This is confirmed using the aaaaal key. The data collected are then recorded and the two prompts are displayed again. ESC Pressing the aaaa key allows a return to the main menu.
15
Page 22
2. Upload data Uploads the data collected, via the selected upload port. The letter displayed on the screen, at the right of the Upload Data line, indicates the selected upload port: RS232 (R) , IR (T), IrDA (I) or Wedge (K). On the PC (under Windows), to receive the data and create a text file, use the application generator, 232_Read.EXE or IR_Read.EXE. For further information, refer to the application generator user manual. 3. Utilities • System settings - Set Upload Port Defines the data upload port: RS232 (cable or download cradle), IR (highspeed infrared transceiver), standard IrDA infrared or screen/keyboard Wedge. The letter displayed on the screen, at the right of the Set Upload Port line, indicates the selected upload port: RS232 (R), IR (T), IrDA (I) or Wedge (K). Default value: RS232. - Set Download Port Defines the port for downloading an application or a file: RS232 (cable or download cradle), IR (high-speed infrared transceiver) or standard IrDA infrared. The letter displayed on the screen, at the right of the Set Download Port line, indicates the selected download port: RS232 (R), IR (T) or IrDA (I). Default value: RS232. - Transmission Speed Defines the transmission speed, up to 115,200 bps. Default value: 115,200 bps. - LCD Backlight Defines the duration of the backlighting. Default value: 20 seconds.
16
Page 23
- Data Deletion Defines whether, after an unload, the data are deleted Manually, with a request for confirmation, or Automatically, with no request for confirmation. Default value: Manually. - Record Prompting Activates (Yes) or de-activates (No) the display of the record number, after confirmation of an entry. Default value: Yes. - View Settings Displays the various settings. • Browse Data Displays the data collected. The aaaa and aaaa keys allow scrolling, in a loop, of all the data collected. • Delete Data Deletes the last record or all the records collected. • Reading Test Tests the read performance of the scanner and displays the bar code read, its length and its type (symbology). The symbologies enabled by default are as follows: Code 39 Industrial 2/5 Interleaved 2/5 Codabar Code 93 Code 128 UPCE without Addon EAN8 EAN13/UPCA without Addon The other symbologies can be enabled by the application generator. • Set Date & Time Defines the date and time.
17
Page 24
• Download Program Downloads an application (*.ATX) created with the application generator into the ScanPall2 Portable Terminal, via the selected download port. The letter displayed on the screen, at the right of the Download Program line, indicates the selected download port: RS232 (R), IR (T) or IrDA (I). On the PC (under Windows), use the application generator or ATX_Load.EXE. For further information, refer to the application generator user manual. • Memory & Battery Displays the size of the data memory (SRAM) in kilobytes, the voltage of the replaceable batteries or the rechargeable battery, and the voltage of the backup battery. • Download Lookup Downloads a Lookup File containing, for example, an item database, into the ScanPall2 Portable Terminal, via the selected download port. On the PC (under Windows), use the application generator or DLookup.EXE. Note: this function is not available if the application loaded does not use a lookup file. For further information, refer to the application generator user manual.
18
Page 25
5.3.
System Mode 7 ABC aaaaal 9 GHI Turn off the ScanPall2 Portable Terminal, and then simultaneously press the aaaaal, and aaaa keys to enter System mode.
System mode offers the following operations:
1 2 3 4 5 6 7
System Menu Memory Setting Reader Battery Test Download Version
1. Memory • Size Information Displays the size of the data memory (SRAM) and the size of the program memory (Flash ROM), in kilobytes. • Initialize Initializes the data memory (SRAM). Note: after an initialization, the data contained in the memory are deleted. • Test Tests the data memory. For a static random access memory (SRAM) size of 256 KB, the test takes around 15 seconds. Note: after a test, the data contained in the memory are deleted. 2. Settings • Clock Defines the date and time. • Backlit Defines the duration of the backlighting. Default value: 20 seconds.
19
Page 26
• Speed Defines the CPU operating speed. Five speeds are available: Speed
Consumption
Full ......................... 39 mA 1/2.......................... 22 mA 1/4.......................... 12 mA 1/8............................ 7 mA 1/16.......................... 5 mA The consumptions are given for normal operation, with no scanner reading or data transmission. If the full-speed mode is not necessary, choose the lowest speed, in order to save the batteries. Default value: Full speed. • Auto Off Defines the time beyond which power down is automatic, when no operation has been performed during this time period. If this value is equal to zero, the function is de-activated. Default value: 10 minutes. • Power On Two possible selections: Program Resume, which starts the program from the last session used before power down; or Program Restart, which restarts the program from the beginning. Default value: Program Resume. • Key Click Enables or Disables the issuing of a sound when a key is pressed. Default value: Enable.
20
Page 27
3. Reader Tests the scanner read performance and displays the bar code read, its length, and a letter identifying the code type (symbology). The symbologies enabled by default are as follows: Symbology
Identifier
Code 39 ..................................... A Industrial 2/5 ..............................D Interleaved 2/5 ........................... E Codabar .....................................G Code 93 .....................................H Code 128 ....................................I UPCE without Addon.................. J EAN8 .........................................M EAN13/UPCA without Addon ..... P The other symbologies must be enabled by programming. 4. Battery • Main Displays the voltage of the replaceable batteries or the rechargeable battery. An icon, representing the battery, is permanently displayed on the screen, thus making it possible to view the charge state. When the battery icon is completely empty, the batteries should be replaced or the rechargeable battery recharged. • Backup Displays the voltage of the backup battery. 5. Test • Buzzer Tests the buzzer by means of the emission of different frequencies and durations. Press the aaaaal key to start or stop the test. • LCD & LED Tests the LCD screen and the dual-colour LED. Press the aaaaal key to start or stop the test.
21