The text of a manual · part 8 of 20
MetroSelect Configuration Guide, pages 71 to 80
Pages 71 to 80 of 200
The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Metrologic QuantumE IS3480
Page 71
SECTION D
INTER-CHARACTER DATA TRANSMISSION DELAYS
Use these codes to select the amount of delay between sending data characters and “Bar Code” records from the scanner to the host. This helps prevent the scanner from overflowing host input buffers. * 1 msec Inter-Character Delay
10 msec Inter-Character Delay
³
³
8
1
8
8
1
0
8
1
8
8
2
1
8
8
1
0
0
~ Variable msec Inter-Character Delay
25 msec Inter-Character Delay
³
8
5
0
³
9
1
8
8
0
0
Scan this bar code and a sequence of code bytes in Section M to set the delay between characters sent to the host system. Delay range can be set from 1 to 255 msecs. Refer to the Multi-Code Configuration Method on page x.
Scanner Operation
D
17
Page 72
Scanner Operation
SECTION D
D
18
INTER-CHARACTER DATA TRANSMISSION DELAYS
No Inter-Character Delay
³
8
1
8
8
0
0
INTER-RECORD DATA TRANSMISSION DELAYS ~ Variable Inter-Record Delay
³
9
1
9
3
0
0
* Leave Laser On During Inter-Record Delay
Turn Off Laser During Inter-Record Delay
³
1
1
9
3
1
7
³
1
1
9
3
0
7
Page 73
SECTION D
COMMUNICATION TIME OUT OPTIONS
Enable Communications Time Outs
* Disable Communications Time Outs
³
³
1
1
8
4
1
2
1
1
8
4
0
* Beep Before Transmit
Beep After Transmit
³
³
1
1
8
4
1
3
1
1
8
4
0
2
3
Scanner will beep before each label is transmitted.
Scanner will beep after each label is transmitted.
~ Variable Communications Time Out
* Default Communications Time Out (2 secs)
³
³
9
1
9
1
0
0
Scanner Operation
D
19
8
1
9
1
4
0
0
Page 74
Scanner Operation
SECTION D
D
20
COMMUNICATION TIME OUT OPTIONS
Short Communications Time Out (1 sec)
Long Communications Time Out (4 secs)
³
³
8
1
9
1
2
0
0
8
1
9
1
8
0
Three Beeps on Time Out
* No Beeps on Time Out
³
³
1
1
8
4
1
0
Razzberry Tone on Time Out
³
1
1
8
4
1
1
8
4
0
0
* No Razzberry Tone on Time Out
1
1
³
1
1
8
4
0
1
0
Page 75
SECTION D
HOST SCANNER COMMANDS
Enable “D/E” Disable Command
³
1
1
8
0
1
* Disable “D/E” Disable
5
³
1
1
8
0
The scanner will disable scanning after it receives and ASCII “D” from the host device. It will enable scanning when it receives an ASCII “E”.
Do not monitor D/E commands.
Enable “Z/R” Type D/E Simulation
* No “Z/R” Type D/E Simulation
³
1
1
8
2
1
1
³
The scanner will disable scanning after it receives an ASCII “Z” from the host device. It will enable scanning when it receives an ASCII “R”.
1
1
8
2
Do not monitor Z/R commands.
Scanner Operation
D
21
0
5
0
1
Page 76
Scanner Operation
SECTION D
D
22
HOST SCANNER COMMANDS
Enable “F/L” Laser Command
* Disable “F/L” Laser Command
³
³
1
1
8
0
1
4
1
1
8
0
0
The scanner will turn off the laser after receiving an ASCII “F” character. The laser will turn on after it receives an ASCII “L” character.
Do not monitor “F/L” commands.
Motor “On/Off” Using M/O Commands †
* Disable “M/O” Commands
4
† For use with omnidirectional scanners only.
³
1
1
8
2
1
3
The scanner will turn the motor OFF after it receives an ASCII “O” character. The motor will turn ON after the scanner receives an ASCII “M” character. †
³
1
1
8
2
0
3
Do not monitor the M/O commands.
Page 77
SECTION D
HOST SCANNER COMMANDS
Enable I Command
³
1
1
5
9
Disable I Command
1
7
³
Enable i Command
³
1
1
5
9
1
1
5
9
0
7
Disable i Command
1
6
³
1
1
5
9
0
6
Enable SI/SO Command
Disable SI/SO Command
³
³
1
2
5
0
1
4
Scanner Operation
D
23
1
2
5
0
0
4
Page 78
Scanner Operation
SECTION D
1
1
8
1
24
HOST SCANNER COMMANDS
Use DTR Scan Disable
³
D
* Do not use DTR Scan Disable
1
5
³
1
1
8
1
0
5
The scanner will monitor the DTR input to determine if scanning should be allowed. A +12V “active” level enables decoding. A -12V “inactive” level disables decoding.
Do not monitor the DTR input.
Enable Pass Through
Disable Pass Through
³
1
2
4
7
1
1
³
1
2
4
7
0
1
The AUX scanner must be configured for the same Baud rate as the host, with STX prefix, Nixdorf ID characters and CR Terminator enabled.
Activate on DC2 Character
* Do Not Activate on DC2 Character
³
³
1
1
8
1
1
0
1
1
8
1
0
0
Page 79
SECTION D
HOST SCANNER COMMANDS
Transmit “NO READ” if DC2 Activated
³
1
1
8
1
1
Do Not Transmit “NO READ” if DC2 Activated
1
³
1
1
8
3
1
1
8
1
0
1
* Green LED During “NO READ” Xmit
No Green LED During “NO READ” Xmit
³
1
1
³
Scanner Operation
D
25
1
1
8
3
0
1
Page 80
Scanner Operation
SECTION D
D
26
POWER SAVE MODES
Always Power Save Mode†
No Power Save Mode† † For use with omnidirectional scanners only.
³
1
1
8
6
1
7
³
8
1
8
6
0
0
The scanner enters power save mode immediately after power-up and after each bar code scanned. †
The scanner will never enter power save mode. †
Power Save Mode in 1 minute †
Power Save Mode in 2 minutes †
³
8
1
8
6
1
0
³
8
1
8
6
2
0
The scanner enters power save mode when the scanner remains idle for 1 min. †
The scanner enters power save mode if the scanner remains idle for 2 min. †
Power Save in 5 Minutes †
Power Save in 10 Minutes †
³
³
8
1
8
6
5
0
The scanner enters power save mode if the scanner remains idle for 5 min. †
8
1
8
6
1
0
0